- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07707440
LMA Protector vs I-Gel in Low-Flow Anesthesia for Laparoscopic Cholecystectomy
11 lipca 2026 zaktualizowane przez: Ahmet Emre Akın, Fatih Sultan Mehmet Training and Research Hospital
Comparison of LMA Protector and I-Gel Use in Low-Flow Anesthesia for Laparoscopic Cholecystectomy: A Prospective Randomized Study
This prospective randomized study aims to compare two second-generation supraglottic airway devices (SGAs), the I-Gel and the laryngeal mask airway (LMA) Protector, in patients undergoing laparoscopic cholecystectomy under low-flow desflurane anesthesia.
The study evaluates the devices in terms of respiratory mechanics (dynamic compliance, peak inspiratory pressure, plateau pressure, and airway resistance), non-invasive perfusion parameters (oxygen reserve index, perfusion index, and pleth variability index), hemodynamic stability, ease of insertion, oropharyngeal leak pressure, and postoperative complication rates.
Przegląd badań
Status
Zakończony
Interwencja / Leczenie
Szczegółowy opis
Sixty-two patients (ASA I-II, aged 18-65 years) scheduled for elective laparoscopic cholecystectomy were randomized into two groups: Group I (I-Gel) and Group P (LMA Protector).
General anesthesia induction was standardized, and maintenance was provided with desflurane at a fresh gas flow of 1 L/min to achieve low-flow anesthesia.
Peak inspiratory pressure (PIP), plateau pressure (Pplato), dynamic compliance (Cdyn), and airway resistance were recorded at six distinct intraoperative time points: 5 minutes after SGA insertion (T1), 1 minute after pneumoperitoneum insufflation (T2), 1 minute after the 30-degree reverse Trendelenburg position (T3), 10 minutes after insufflation (T4), 1 minute after desufflation (T5), and immediately before SGA removal (T6).
Oropharyngeal leak pressure (OLP) was measured after insertion and before removal.
Postoperative complications such as sore throat, cough, hoarseness, dysphagia, and nausea-vomiting were monitored postoperatively.
Typ studiów
Interwencyjne
Zapisy (Rzeczywisty)
62
Faza
- Nie dotyczy
Kontakty i lokalizacje
Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.
Lokalizacje studiów
-
-
-
Istanbul, Turcja (Türkiye), 34752
- Fatih Sultan Mehmet Training and Research Hospital
-
-
Kryteria uczestnictwa
Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Nie
Opis
Inclusion Criteria:
- Patients aged 18-65 years
- American Society of Anesthesiologists (ASA) physical status I or II
- Scheduled for elective laparoscopic cholecystectomy
Exclusion Criteria:
- Known or predicted difficult airway or history of difficult intubation
- Body Mass Index (BMI) greater than 35 kg/m²
- High risk of gastroesophageal reflux or aspiration
- Severe cardiac, respiratory, renal, or hepatic disease
- Pregnancy
- Patient refusal to participate
Plan studiów
Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Pojedynczy
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Group I: I-Gel
Patients managed with the I-Gel supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of i-gel supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Inne nazwy:
|
|
Eksperymentalny: Group P: LMA Protector
Patients managed with the LMA Protector supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of LMA Protector supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Dynamic Lung Compliance (Cdyn)
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Dynamic compliance of the respiratory system, calculated automatically by the ventilator as tidal volume divided by (peak inspiratory pressure minus positive end-expiratory pressure).
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Peak Inspiratory Pressure (PIP)
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Maximum airway pressure generated during the inspiratory phase, monitored to assess airway dynamics under general anesthesia.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Plateau Pressure (Pplateau)
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Pressure applied to the small airways and alveoli during a period of zero gas flow, monitored to assess risk of barotrauma.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Airway Resistance
Ramy czasowe: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
The resistance of the respiratory tract to airflow during mechanical ventilation, calculated using peak and plateau pressures.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Współpracownicy i badacze
Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.
Współpracownicy
Daty zapisu na studia
Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
1 lipca 2020
Zakończenie podstawowe (Rzeczywisty)
31 października 2020
Ukończenie studiów (Rzeczywisty)
31 października 2020
Daty rejestracji na studia
Pierwszy przesłany
5 lipca 2026
Pierwszy przesłany, który spełnia kryteria kontroli jakości
11 lipca 2026
Pierwszy wysłany (Rzeczywisty)
16 lipca 2026
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
16 lipca 2026
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
11 lipca 2026
Ostatnia weryfikacja
1 lipca 2026
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
- FSM KAEK-2020/79
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
NIE
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Nie
Bada produkt urządzenia regulowany przez amerykańską FDA
Nie
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .