Hemostatic Agents in Hepatobiliary and Pancreas Surgery: A Review of the Literature and Critical Evaluation of a Novel Carrier-Bound Fibrin Sealant (TachoSil)

K A Simo, E M Hanna, D K Imagawa, D A Iannitti, K A Simo, E M Hanna, D K Imagawa, D A Iannitti

Abstract

Background. Despite progress in surgical techniques applied during hepatobiliary and pancreas (HPB) surgery, bleeding and bile leak remain significant contributors to postoperative mortality and morbidity. Topical hemostatics have been developed and utilized across surgical specialties, but data regarding effectiveness remains inconsistent and sparse in HPB surgery. Methods. A comprehensive search for studies and reviews on hemostatics in HPB surgery was performed via an October 2011 query of Medline, EMBASE, and Cochrane Library. In-depth evaluation of a novel carrier-bound fibrin sealant (TachoSil) was also performed. Results. The literature review illustrates multiple attempts have been made at developing different topical hemostatics and sealants to aid in surgical procedures. In HPB surgery, efforts have been directed at decreasing bleeding, biliary leakage, and pancreatic fistula. Conflicting scientific evidence exists regarding the effectiveness of these agents. Critical evaluation of the literature demonstrates TachoSil is a valuable tool in achieving hemostasis, and possibly biliostasis and pancreatic fistula prevention. Conclusion. While progress has been made in topical hemostatics for HPB surgery, an ideal agent has not yet been identified. TachoSil is promising, but larger randomized, controlled clinical trials are required to more fully evaluate its efficacy in reducing bleeding, biliary leakage, and pancreatic fistulas in HPB surgery.

Figures

Figure 1
Figure 1
QUORUM flowchart.
Figure 2
Figure 2
TachoSil packaging.
Figure 3
Figure 3
TachoSil Ready-To-Use Surgical Patch. Coating anchored to the indentions as denoted by arrow.
Figure 4
Figure 4
Hemostatic matrix mechanism of action of TachoSil illustrated via the coagulation cascade.

References

    1. Jarnagin WR, Gonen M, Fong Y, et al. Improvement in perioperative outcome after hepatic resection: analysis of 1,803 consecutive cases over the past decade. Annals of Surgery. 2002;236(4):397–407.
    1. Briceño J, Naranjo A, Ciria R, et al. A prospective study of the efficacy of clinical application of a new carrier-bound fibrin sealant after liver resection. Archives of Surgery. 2010;145(5):482–488.
    1. Makuuchi M, Sano K. The surgical approach to HCC: our progress and results in Japan. Liver Transplantation. 2004;10(2, supplement 1):S46–S52.
    1. Figueras J, Llado L, Miro M, et al. Application of fibrin glue sealant after hepatectomy does not seem justified: results of a randomized study in 300 patients. Annals of Surgery. 2007;245(4):536–542.
    1. Kraus TW, Mehrabi A, Schemmer P, Kashfi A, Berberat P, Büchler MW. Scientific evidence for application of topical hemostats, tissue glues, and sealants in hepatobiliary surgery. Journal of the American College of Surgeons. 2005;200(3):418–427.
    1. Boonstra EA, Molenaar IQ, Porte RJ, de Boer MT. Topical haemostatic agents in liver surgery: do we need them? HPB. 2009;11(4):306–310.
    1. Spotnitz WD, Burks S. Hemostats, sealants, and adhesives: components of the surgical toolbox. Transfusion. 2008;48(7):1502–1516.
    1. Spotnitz WD, Burks S. Hemostats, sealants, and adhesives II: update as well as how and when to use the components of the surgical toolbox. Clinical and Applied Thrombosis/Hemostasis. 2010;16(5):497–514.
    1. Spotnitz WD. Fibrin sealant: past, present, and future: a brief review. World Journal of Surgery. 2010;34(4):632–634.
    1. Berrevoet F, de Hemptinne B. Use of topical hemostatic agents during liver resection. Digestive Surgery. 2007;24(4):288–293.
    1. Hayashibe A, Sakamoto K, Shinbo M, Makimoto S, Nakamoto T. New method for prevention of bile leakage after hepatic resection. Journal of Surgical Oncology. 2006;94(1):57–60.
    1. Adams GL, Manson RJ, Hasselblad V, Shaw LK, Lawson JH. Acute in-vivo evaluation of bleeding with Gelfoam saline and Gelfoam plus human thrombin using a liver square lesion model in swine. Journal of Thrombosis and Thrombolysis. 2009;28(1):1–5.
    1. Leixnering M, Reichetseder J, Schultz A, et al. Gelatin thrombin granules for hemostasis in a severe traumatic liver and spleen rupture model in swine. The Journal of Trauma. 2008;64(2):456–461.
    1. Chapman WC, Clavien PA, Fung J, Khanna A, Bonham A, Kram HB. Effective control of hepatic bleeding with a novel collagen-based composite combined with autologous plasma: results of a randomized controlled trial. Archives of Surgery. 2000;135(10):1200–1205.
    1. Fingerhut A, Veyrie N, Ata T, Alexakis N, Leandros E. Use of sealants in pancreatic surgery: critical appraisal of the literature. Digestive Surgery. 2009;26(1):7–14.
    1. Schwartz M, Madariaga J, Hirose R, et al. Comparison of a new fibrin sealant with standard topical hemostatic agents. Archives of Surgery. 2004;139(11):1148–1154.
    1. Joseph T, Adeosun A, Paes T, Bahal V. Randomised controlled trial to evaluate the efficacy of TachoComb H patches in controlling PTFE suture-hole bleeding. European Journal of Vascular and Endovascular Surgery. 2004;27(5):549–552.
    1. Rickenbacher A, Breitenstein S, Lesurtel M, Frilling A. Efficacy of TachoSil a fibrin-based haemostat in different fields of surgery—a systematic review. Expert Opinion on Biological Therapy. 2009;9(7):897–907.
    1. Federal Drug Administration. TachoSil (Absorbable Fibrin Sealant Patch) Prescribing Information. In, Initial US approval. 2010.
    1. Haas S. The use of a surgical patch coated with human coagulation factors in surgical routine: a multicenter postauthorization surveillance. Clinical and Applied Thrombosis/Hemostasis. 2006;12(4):445–450.
    1. Toro A, Mannino M, Reale G, Di Carlo I. TachoSil use in abdominal surgery: a review. Jorunal of Blood Medicine. 2011;2:31–36.
    1. Dregelid EB, Pedersen G. Treatment of major vein injury with the hemostatic fleece TachoSil by interposing a peritoneal patch to avoid vein thrombosis: a feasibility study in pigs. Journal of Emergencies, Trauma and Shock. 2011;4(1):77–81.
    1. Apestegui C, Breitenstein S, Dutkowski P, Clavien PA. Control of severe portal bleeding by carrier-bound fibrin sealant. Surgery Today. 2009;39(4):363–365.
    1. Abu Hilal M, Hallam MJ, Zeidan BA, Pearce NW. Management of a ruptured pseudoaneurysm of common hepatic artery following pancreaticoduodenectomy. The Scientific World Journal. 2007;7:1659–1662.
    1. Shimamoto T, Marui A, Nishina T, Saji Y, Komeda M. The TachoSil-pledget stitch: towards eradication of suture hole bleeding. Annals of Thoracic Surgery. 2008;86(6):2002–2004.
    1. Schelling G, Block T, Gokel M, Blanke E, Hammer C, Brendel W. Application of a fibrinogen-thrombin-collagen-based hemostyptic agent in experimental injuries of liver and spleen. The Journal of Trauma. 1988;28(4):472–475.
    1. Grottke O, Braunschweig T, Daheim N, et al. Effect of TachoSil in a coagulopathic pig model with blunt liver injuries. Journal of Surgical Research. 2010;171(1):234–239.
    1. Takács I, Wegmann J, Horváth S, et al. Efficacy of different hemostatic devices for severe liver bleeding: a randomized controlled animal study. Surgical Innovation. 2010;17(4):346–352.
    1. Pusateri AE, Modrow HE, Harris RA, et al. Advanced hemostatic dressing development program: animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in swine. The Journal of Trauma. 2003;55(3):518–526.
    1. Erdogan D, de Graaf W, van Gulik TM. Adhesive strength of fibrinogen-coated collagen patch or liquid fibrin sealant in an experimental liver resection model in pigs. European Surgical Research. 2008;41(3):298–302.
    1. Eder F, Meyer F, Nestler G, Halloul Z, Lippert H. Sealing of the hepatic resection area using fibrin glue reduces significant amount of postoperative drain fluid. World Journal of Gastroenterology. 2005;11(38):5984–5987.
    1. Davidson BR, Burnett S, Javed MS, Seifalian A, Moore D, Doctor N. Experimental study of a novel fibrin sealant for achieving haemostasis following partial hepatectomy. British Journal of Surgery. 2000;87(6):790–795.
    1. Saif R, Jacob M, Robinson S, Amer A, Kei-Hui D, Sen G, et al. Use of fibrin-based sealants and gelatin-matrix hemostats in laparoscopic liver surgery. Surgical Laparoscopy Endoscopy & Percutaneous Techniques. 2011;21(3):131–141.
    1. Capussotti L, Ferrero A, Viganò L, Sgotto E, Muratore A, Polastri R. Bile leakage and liver resection: where is the risk? Archives of Surgery. 2006;141(7):690–694.
    1. Sarpel U, Roayaie S, Schwartz ME, Labow DM. The role of fibrin sealants in hepatic surgery. Surgical Technology International. 2007;16:31–36.
    1. Berrevoet F, de Hemptinne B. Clinical application of topical sealants in liver surgery: does it work? Acta Chirurgica Belgica. 2007;107(5):504–507.
    1. Moench C, Bechstein WO, Hermanutz V, Hoexter G, Knaebel HP. Comparison of the collagen haemostat Sangustop versus a carrier-bound fibrin sealant during liver resection; ESSCALIVER-Study. Trials. 2010;11, article 109
    1. Frilling A, Stavrou GA, Mischinger HJ, et al. Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbeck’s Archives of Surgery. 2005;390(2):114–120.
    1. Fischer L, Seiler CM, Broelsch CE, et al. Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: an open, randomized, prospective, multicenter, parallel-group trial. Surgery. 2011;149(1):48–55.
    1. Mirza D, Millar AJW, Sharif K, Vilca-Melendez H, Rela M, Heaton N. The use of TachoSil in children undergoing liver resection with or without segmental liver transplantation. European Journal of Pediatric Surgery. 2011;21(2):111–115.
    1. Lacanna F, Brunati A, Reding R. A new biological mesh for cut surface hemostasis in liver transplantation using technical variants. Pediatric Transplantation. 2008;12(5):520–521.
    1. Toti L, Attia M, Manzia TM, et al. Reduction in bile leaks following adult split liver transplant using a fibrin-collagen sponge: a pilot study. Digestive and Liver Disease. 2010;42(3):205–209.
    1. Saxena AK, Van Tuil C. Advantages of fibrin glue spray in laparoscopic liver biopsies. Surgical Laparoscopy, Endoscopy and Percutaneous Techniques. 2007;17(6):545–547.
    1. Nakajima K, Yasumasa K, Endo S, et al. A simple application technique of fibrin-coated collagen fleece (TachoComb) in laparoscopic surgery. Surgery Today. 2007;37(2):176–179.
    1. Scheyer M, Zimmermann G. Tachocomb used in endoscopic surgery. Surgical Endoscopy. 1996;10(5):501–503.
    1. Carbon RT, Baar S, Waldschmidt J, Huemmer HP, Simon SI. Innovative minimally invasive pediatric surgery is of therapeutic value for splenic injury. Journal of Pediatric Surgery. 2002;37(8):1146–1150.
    1. Erdogru T, Sanli A, Celik O, Baykara M. Laparoscopic transvesical repair of recurrent vesicovaginal fistula using with fleece-bound sealing system. Archives of Gynecology and Obstetrics. 2008;277(5):461–464.
    1. Falsaperla M, Autorino R, Puglisi M, et al. Haemostatic agents during laparoscopic nephron-sparing surgery: what about TachoSil? BJU International. 2009;104(2):270–271.
    1. Rane A, Rimington PD, Heyns CF, van der Merwe A, Smit S, Anderson C. Evaluation of a hemostatic sponge (TachoSil) for sealing of the renal collecting system in a porcine laparoscopic partial nephrectomy survival model. Journal of Endourology. 2010;24(4):599–603.
    1. Low JK, Ayiomamitis GD, Hamoudi A, Ammori BJ. Spontaneous rupture of the splenic capsule with massive bleeding subsequent to the pringle maneuver during laparoscopic liver resection. Surgical Laparoscopy, Endoscopy and Percutaneous Techniques. 2011;21(2):e84–e86.
    1. Mita K, Ito H, Fukumoto M, et al. Pancreaticojejunostomy using a fibrin adhesive sealant (TachoComb) for the prevention of pancreatic fistula after pancreaticoduodenectomy. Hepato-Gastroenterology. 2011;58(105):187–191.
    1. Mita K, Ito H, Fukumoto M, et al. A fibrin adhesive sealing method for the prevention of pancreatic fistula following distal pancreatectomy. Hepato-Gastroenterology. 2011;58(106):604–608.
    1. Chirletti P, Caronna R, Fanello G, et al. Pancreaticojejunostomy with applicationof fibrinogen/thrombin-coated collagen patch (TachoSil) in roux-en-Y reconstruction after pancreaticoduodenectomy. Journal of Gastrointestinal Surgery. 2009;13(7):1396–1398.
    1. Lorenz U, Maier M, Steger U, Töpfer C, Thiede A, Timm S. Analysis of closure of the pancreatic remnant after distal pancreatic resection. HPB. 2007;9(4):302–307.
    1. Pavlik Marangos I, Røsok BI, Kazaryan AM, Rosseland AR, Edwin B. Effect of TachoSil patch in prevention of postoperative pancreatic fistula. Journal of Gastrointestinal Surgery. 2011;15(9):1625–1629.
    1. Røsok BI, Marangos IP, Kazaiyan AM, et al. Single-centre experience of laparoscopic pancreatic surgery. British Journal of Surgery. 2010;97(6):902–909.
    1. Seeliger H, Christians S, Angele MK, et al. Risk factors for surgical complications in distal pancreatectomy. American Journal of Surgery. 2010;200(3):311–317.
    1. Erdogan D, Van Gulik TM. Evolution of fibrinogen-coated collagen patch for use as a topical hemostatic agent. Journal of Biomedical Materials Research B. 2008;85(1):272–278.
    1. Lorenz D, Scheele J. The use of collagen fleece (Tachocomb) in pancreatic surgery. Zeitschrift für Experimentelle Chirurgie Transplantation und Künstliche Organe. 1990;23(2):93–94.

Source: PubMed

3
Abonneren