Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial

Anup C Katheria, Madeline Wozniak, David Harari, Kathy Arnell, Deborah Petruzzelli, Neil N Finer, Anup C Katheria, Madeline Wozniak, David Harari, Kathy Arnell, Deborah Petruzzelli, Neil N Finer

Abstract

Background: To date no study has attempted to continuously evaluate changes in hemodynamics during delayed cord clamping in humans. We aimed to demonstrate 1. the feasibility of measurements of hemodynamics during delayed cord clamping and 2. to describe the changes that occur over each minute.

Results: After vaginal delivery, term infants (37(0)-41(6) weeks) were placed on a Life Start® bed 10-20 cm below the placenta. Transcutaneous sensors were placed on the neck and chest to determine heart rate, stroke volume and cardiac output at each beat. Once a signal was obtained, first 5 values (taken every beat) were averaged and the percent change for each subject from baseline was calculated. 20 infants were enrolled and all had a reliable signal obtained from transcutaneous sensors and had a delay in cord clamping for about 5 minutes. Cardiac output increased from 2 to 5 minutes of life (p = 0.008). For every minute of life the cord was kept unclamped, the stroke volume increased 13.1% ± 12.3 (p = 0.0001) and cardiac output increased 12.6% ± 6.3 from baseline (p < 0.0001). While the majority of infants continued to have an increase in cardiac output at 5 minutes of life, 7/20 infants reached their peak cardiac output at 188 ± 41 seconds of life.

Conclusions: This study demonstrates that hemodynamic measures could be successfully obtained during the first five minutes of birth and while a newborn was receiving delayed cord clamping. This study also provides reference values for changes in cardiac output and stroke volume in well term infants during delayed cord clamping.

Trial registration: Clinical Trials.gov NCT02195037 Registered 17 July 2014.

Keywords: Cardiac output; Delayed cord clamping; Hemodynamics; Transitional circulation.

Figures

Figure 1
Figure 1
Demonstration of the Life Start Bed. (A) Bed placement in delivery room (B) ICON monitor and leads applied to above the ear, side of the neck, level of the xiphoid, and inguinal canal.
Figure 2
Figure 2
Percent change in heart rate, stroke volume, and cardiac output during delayed cord clamping over first 5 minutes. * p 

References

    1. WHO Guidelines Approved by the Guidelines Review Committee . Guidelines on basic newborn resuscitation. Geneva: World Health Organization; 2012.
    1. Committee Opinion No.543: Timing of umbilical cord clamping after birth. Obstet Gynecol. 2012;120(6):1522–6. doi:10.1097/01.aog.0000423817.47165.48.
    1. Yigit MB, Kowalski WJ, Hutchon DJ, Pekkan K. Transition from fetal to neonatal circulation: modeling the effect of umbilical cord clamping. J Biomech. 2015. doi:10.1016/j.jbiomech.2015.02.040.
    1. McDonald SJ, Middleton P, Dowswell T, Morris PS. Cochrane in context: Effect of timing of umbilical cord clamping in term infants on maternal and neonatal outcomes. Evidence-based child health: a Cochrane review journal. 2014;9(2):398–400. doi: 10.1002/ebch.1965.
    1. Ceriani Cernadas JM, Carroli G, Pellegrini L, Otano L, Ferreira M, Ricci C, et al. he effect of timing of cord clamping on neonatal venous hematocrit values and clinical outcome at term: a randomized, controlled trial. Pediatrics. 2006;117(4):e779–86. doi: 10.1542/peds.2005-1156.
    1. Andersson O, Hellstrom-Westas L, Andersson D, Domellof M. Effect of delayed versus early umbilical cord clamping on neonatal outcomes and iron status at 4 months: a randomised controlled trial. BMJ. 2011;343:d7157. doi: 10.1136/bmj.d7157.
    1. Raju TN. Timing of umbilical cord clamping after birth for optimizing placental transfusion. Curr Opin Pediatr. 2013;25(2):180–7. doi: 10.1097/MOP.0b013e32835d2a9e.
    1. Committee on Obstetric Practice ACoO, Gynecologists Committee opinion No.543: timing of umbilical cord clamping after birth. Obstet Gynecol. 2012;120(6):1522–6. doi: 10.1097/01.AOG.0000423817.47165.48.
    1. Rabe H, Diaz-Rossello JL, Duley L, Dowswell T. Effect of timing of umbilical cord clamping and other strategies to influence placental transfusion at preterm birth on maternal and infant outcomes. Cochrane Database Syst Rev. 2012;8:CD003248.
    1. Mercer JS, Erickson-Owens DA. Rethinking placental transfusion and cord clamping issues. J Perinat Neonatal Nurs. 2012;26(3):202–17. doi: 10.1097/JPN.0b013e31825d2d9a.
    1. van Vonderen JJ, Roest AA, Siew ML, Blom NA, van Lith JM, Walther FJ, et al. Noninvasive measurements of hemodynamic transition directly after birth. Pediatr Res. 2014;75(3):448–52. doi: 10.1038/pr.2013.241.
    1. Bhatt S, Alison BJ, Wallace EM, Crossley KJ, Gill AW, Kluckow M, et al. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs. J Physiol. 2013;591(Pt 8):2113–26. doi: 10.1113/jphysiol.2012.250084.
    1. Bernstein DP, Lemmens HJ. Stroke volume equation for impedance cardiography. Med Biol Eng Comput. 2005;43(4):443–50. doi: 10.1007/BF02344724.
    1. Tsai-Goodman B, Martin RP, Marlow N, Skinner JR. The repeatability of echocardiographic determination of right ventricular output in the newborn. Cardiol Young. 2001;11(2):188–94. doi: 10.1017/S1047951101000099.
    1. Song RS KJ, Finer NN, Katheria AC. The impact of ventilation on cardiac output measurements using electrocardiometry compared to echocardiography in Neonates. E-PAS 2012;4528461. 2012.
    1. Noori S, Drabu B, Soleymani S, Seri I. Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed. 2012;97(5):F340–3. doi: 10.1136/fetalneonatal-2011-301090.
    1. Smit M, Dawson JA, Ganzeboom A, Hooper SB, van Roosmalen J, te Pas AB. Pulse oximetry in newborns with delayed cord clamping and immediate skin-to-skin contact. Arch Dis Child Fetal Neonatal Ed. 2014;99(4):F309–14. doi: 10.1136/archdischild-2013-305484.
    1. Sommers R, Stonestreet BS, Oh W, Laptook A, Yanowitz TD, Raker C, et al. Hemodynamic effects of delayed cord clamping in premature infants. Pediatrics. 2012;129(3):e667–72. doi: 10.1542/peds.2011-2550.
    1. McDonald SJ, Middleton P, Dowswell T, Morris PS. Effect of timing of umbilical cord clamping of term infants on maternal and neonatal outcomes. Cochrane Database Syst Rev. 2013;7:CD004074.
    1. Boere I, Roest AA, Wallace E, Ten Harkel AD, Haack MC, Morley CJ, Hooper SB, Te Pas AB. Umbilical blood flow patterns directly after birth before delayed cord clamping. Arch Dis Child Fetal Neonatal Ed. 2015;100:2. doi: 10.1136/archdischild-2014-307144.

Source: PubMed

3
Abonneren