Automated versus non-automated weaning for reducing the duration of mechanical ventilation for critically ill adults and children: a cochrane systematic review and meta-analysis

Louise Rose, Marcus J Schultz, Chris R Cardwell, Philippe Jouvet, Danny F McAuley, Bronagh Blackwood, Louise Rose, Marcus J Schultz, Chris R Cardwell, Philippe Jouvet, Danny F McAuley, Bronagh Blackwood

Abstract

Introduction: Automated weaning systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.

Methods: Electronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.

Results: We identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I(2) = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.

Conclusions: Automated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Figures

Figure 1
Figure 1
Study flow diagram.
Figure 2
Figure 2
Risk of bias summary.
Figure 3
Figure 3
Duration of weaning by study population.
Figure 4
Figure 4
Duration of weaning by automated system.
Figure 5
Figure 5
Duration of ventilation by automated system.
Figure 6
Figure 6
Mortality.
Figure 7
Figure 7
Hospital length of stay.
Figure 8
Figure 8
ICU length of stay by study population.
Figure 9
Figure 9
Prolonged mechanical ventilation.
Figure 10
Figure 10
Tracheostomy.

References

    1. MacIntyre NR. Evidence-based guidelines for weaning and discontinuing ventilatory support. Chest. 2001;120:375S–395S. doi: 10.1378/chest.120.6_suppl.375S.
    1. Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, et al. Weaning from mechanical ventilation. Eur Resp J. 2007;29:1033–1056. doi: 10.1183/09031936.00010206.
    1. Ely EW, Meade MO, Haponik EF, Kollef MH, Cook DJ, Guyatt GH, et al. Mechanical ventilator weaning protocols driven by nonphysician health-care professionals: evidence-based clinical practice guidelines. Chest. 2001;120:454S–463S. doi: 10.1378/chest.120.6_suppl.454S.
    1. Blackwood B, Alderdice F, Burns K, Cardwell C, Lavery G, O’Halloran P. Protocolized versus non-protocolized weaning for reducing the duration of mechanical ventilation in critically ill adult patients. Cochrane Database Syst Rev. 2010;5
    1. Lellouche F, Brochard L. Advanced closed loops during mechanical ventilation (PAV, NAVA, ASV, SmartCare) Best Pract Res Clin Anaesthesiol. 2009;23:81–93. doi: 10.1016/j.bpa.2008.08.001.
    1. Zilberberg M, de Wit M, Shorr A. Accuracy of previous estimates for adult prolonged acute mechanical ventilation volume in 2020: update using 2000–2008 data. Crit Care Med. 2012;40:18–20. doi: 10.1097/CCM.0b013e31822e9ffd.
    1. Wunsch H, Linde-Zwirble W, Angus D, Hartman M, Milbrandt E, Kahn J. The epidemiology of mechanical ventilation use in the United States. Crit Care Med. 2010;38:1947–1953.
    1. Zolnierek C, Steckel C. Negotiating safety when staffing falls short. Crit Care Nurs Clin North Am. 2010;22:261–269. doi: 10.1016/j.ccell.2010.03.014.
    1. Angus D, Shorr A, White A, Deremsiziv T, Schmitz R, Kelley M. Critical care delivery in the United States: distribution of services and compliance with leapfrog recommendations. Crit Care Med. 2006;34:1016–1024. doi: 10.1097/01.CCM.0000206105.05626.15.
    1. Rose L, Schultz M, Cardwel C, Jouvet P, McAuley D, Blackwood B. Automated versus non-automated weaning for reducing the duration of mechanical ventilation for critically ill adults and children (review) Cochrane Database Syst Rev. 2014;6
    1. Leclerc F, Noizet O, Botte A, Binoche A, Chaari W, Sadik A, et al. Weaning from invasive mechanical ventilation in pediatric patients (excluding premature neonates) Arch Pediatrics. 2010;17:399–406. doi: 10.1016/j.arcped.2010.01.017.
    1. Cochrane Handbook for Systematic Reviews of Interventions 5.1.0. In: Higgins J, Green S: (eds) The Cochrane Collaboration. . 2011, Section 7.7.3.5.
    1. DeMets D. Methods for combining randomized clinical trials. Stat Med. 1987;6:341–350. doi: 10.1002/sim.4780060325.
    1. Jouvet P, Payen V, Gauvin F, Emeriaud G, Lacroix J. Weaning children from mechanical ventilation with a computer-driven protocol: a pilot trial. Intensive Care Med. 2013;39:919–925. doi: 10.1007/s00134-013-2837-8.
    1. Kirakli C, Ozdemir I, Ucar Z, Cimen P, Kepil S, Ozkan S. Adaptive support ventilation for faster weaning in COPD: a randomised controlled trial. Eur Respir J. 2011;38:774–780. doi: 10.1183/09031936.00081510.
    1. Rose L, Presneill J, Johnston L, Cade J. A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med. 2008;34:1788–1795. doi: 10.1007/s00134-008-1179-4.
    1. Schädler D, Engel C, Elke G, Pulletz S, Haake N, Frerichs I, et al. Automatic control of pressure support for ventilator weaning in surgical intensive care patients. Am J Respir Crit Care Med. 2012;185:637–644. doi: 10.1164/rccm.201106-1127OC.
    1. Xirouchaki N, Kondili E, Vaporidi K, Xirouchakis G, Klimathianaki M, Gavriilidis G, et al. Proportional assist ventilation with load-adjustable gain factors in critically ill patients: comparison with pressure support. Intensive Care Med. 2008;34:2026–2034. doi: 10.1007/s00134-008-1209-2.
    1. Dongelmans D, Veelo D, Paulus F, de Mol B, Korevaar J, Kudoga A, et al. Weaning automation with adaptive support ventilation: a randomized controlled trial in cardiothoracic surgery patients. Anesth Analg. 2009;108:565–571. doi: 10.1213/ane.0b013e318190c49f.
    1. Aghadavoudi O, Kamran M, Masoudifar M. Comparison of two modes of ventilation after fast-track cardiac surgery: adaptive support ventilation versus synchronized intermittent mandatory ventilation. Pakistan J Med Sci. 2012;28:303–308.
    1. Davis S, Potgieter P, Linton D. Mandatory minute volume weaning in patients with pulmonary pathology. Anaesthesia Intensive Care. 1989;17:170–174.
    1. Hendrix H, Kaiser M, Yusen R, Merk J. A randomized trial of automated versus conventional protocol-driven weaning from mechanical ventilation following coronary artery bypass surgery. Eur J Cardiothor Surg. 2006;29:957–963. doi: 10.1016/j.ejcts.2006.01.036.
    1. Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, et al. A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med. 2006;174:894–900. doi: 10.1164/rccm.200511-1780OC.
    1. Roth H, Luecke T, Lansche G, Bender H, Quintel M. Effects of patient-triggered automatic switching between mandatory and supported ventilation in the postoperative weaning patients. Intensive Care Med. 2001;27:47–51. doi: 10.1007/s001340000759.
    1. Strickland JH, Jr, Hasson JH. A computer-controlled ventilator weaning system. A clinical trial. Chest. 1993;103:1220–1226. doi: 10.1378/chest.103.4.1220.
    1. Taniguchi C, Eid R, Saghabi C, Souza R, Silva E, Knobel E, et al. Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomised controlled trial. Crit Care. 2009;13:R6.
    1. Walkey A, Reardon C. Clinical trial of a computer driven weaning system for patients requiring mechanical ventilation. Available from .
    1. Ramet J, Van Herreweghe I, Idrissi S, Huyghens L. Computerized switch of ventilation mode during weaning [abstract]. Intensive Care Med. 2002;28:S123.
    1. Agarwal S, Srinivasan A, Aggarwal A, Gupta D. Adaptive support ventilation for complete ventilatory support in acute respiratory distress syndrome: a pilot, randomized controlled trial. Respirology. 2013;18:1108–1115.
    1. Burns KE, Meade MO, Lessard MR, Hand L, Zhou Q, Keenan SP, et al. Wean earlier and automatically with new technology (the WEAN study). A multicenter, pilot randomized controlled trial. Am J Respir Crit Care Med. 2013;187:1203–1211. doi: 10.1164/rccm.201206-1026OC.
    1. Liu L, Xu X, Yang Y, Huang Y, Liu S, Qiu H. Computer-driven automated weaning reduces weaning duration in difficult-to-wean patients. Chin Med J. 2013;126:1814–1818.
    1. Petter A, Chiolero R, Cassina T, Chassot PG, Muller XM, Revelly JP. Automatic respirator weaning with adaptive support ventilation: the effect on duration of endotracheal intubation and patient management. Anesth Analgesia. 2003;97:1743–1750. doi: 10.1213/.
    1. Stahl C, Dahmen G, Ziegler A, Muhl E. Protocolized automated versus non-protocolized physician-directed weaning from mechanical ventilation: a controlled clinical trial. Intensivemed Prax. 2009;46:441–446.
    1. Sulzer CF, Chiolero R, Chassot PG, Mueller XM, Revelly JP. Adaptive support ventilation for fast tracheal extubation after cardiac surgery: a randomized controlled study. Anesthesiology. 2001;95:1339–1345. doi: 10.1097/00000542-200112000-00010.
    1. Hozo S, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol. 2005;5:13. doi: 10.1186/1471-2288-5-13.
    1. Bland J, Altman D. The use of transformation when comparing two means. BMJ. 1996;312:1153. doi: 10.1136/bmj.312.7039.1153.
    1. The Nordic Cochrane Centre, The Cochrane Collaboration. Review Manager (RevMan), Version 5.2 for Windows (computer program). 2012, Copenhagen.
    1. Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315:629–634. doi: 10.1136/bmj.315.7109.629.
    1. Esteban A, Ferguson N, Meade M, Frutos-Vivar F, Apezteguia C, Brochard L, et al. Evolution of mechanical ventilation in response to clinical research. Am J Respir Crit Care Med. 2008;177:170–7. doi: 10.1164/rccm.200706-893OC.
    1. Clarke M. Standardising outcomes for clinical trials and systematic reviews. Trials. 2007;8:39. doi: 10.1186/1745-6215-8-39.
    1. Payen V, Jouvet P, Lacroix J, Ducruet T, Gauvin F. Risk factors associated with increased length of mechanical ventilation in children. Ped Crit Care Med. 2012;13:152–157. doi: 10.1097/PCC.0b013e3182257a24.

Source: PubMed

3
Abonneren