Influence of different frequencies of transcutaneous electrical nerve stimulation on the threshold and pain intensity in young subjects

Adriana de Oliveira Gomes, Ana Caroline Silvestre, Cristina Ferreira da Silva, Mariany Ribeiro Gomes, Maria Lúcia Bonfleur, Gladson Ricardo Flor Bertolini, Adriana de Oliveira Gomes, Ana Caroline Silvestre, Cristina Ferreira da Silva, Mariany Ribeiro Gomes, Maria Lúcia Bonfleur, Gladson Ricardo Flor Bertolini

Abstract

Objective: To investigate the effects of different transcutaneous electrical nerve stimulation frequencies in nociception front of a pressure pain threshold and cold in healthy individuals.

Methods: Twenty healthy subjects were divided into four groups, all of which have gone through all forms of electrical stimulation at different weeks. Assessments were pre and post-therapy, 20 and 60 minutes after stimulation. To evaluate the pressure pain threshold, an algometer was used with one tapered tip, pressing the hypothenar region until voluntary report the word "pain". Cold pain intensity was assessed by immersion in water at 5°C for 30 seconds; at the end, the subject was asked to quantify the pain intensity on a Visual Analog Scale for Pain. For electrical stimulation, two electrodes were used near the elbow, for 20 minutes, with an intensity strong, but not painful. The frequency was in accordance with the group: 0Hz (placebo); 7Hz; 100Hz; and 255Hz.

Results: Both for the assessment of pressure pain threshold as the cold pain intensity, there was no significant difference (p>0.05).

Conclusion: We conclude that the use of transcutaneous electrical nerve stimulation on dermatomes C6 to C8 produced no significant change in pressure pain threshold or cold discomfort.

Conflict of interest statement

Conflict of interest: none.

Figures

Figure 1. Positioning of electrodes on the…
Figure 1. Positioning of electrodes on the superficial region of the median and ulnar nerves, near the elbow joint
Figura 1. Posicionamento dos eletrodos na região…
Figura 1. Posicionamento dos eletrodos na região de superficialidade dos nervos mediano e ulnar, próximos à articulação do cotovelo

References

    1. Montenegro EJ, Albuquerque NB, Mariz LM, Costa RC, Montarroyos CS, Motta MA. Ação da TENS acupuntural em acupontos na dor induzida pela hipotermia local (0-2oC) Fisioter Mov. 2010;23(3):483–492.
    1. Sabino GS, Santos CM, Francischi JN, Resende MA. Release of endogenous opioids following transcutaneous electric nerve stimulation in an experimental model of acute inflammatory pain. J Pain. 2008;9(2):157–163.
    1. Rakel B, Cooper N, Adams HJ, Messer BR, Frey Law LA, Dannen DR, et al. A new transient sham TENS device allows for investigator blinding while delivering a true placebo treatment. J Pain. 2010;11(3):230–238.
    1. Schulz AP, Chao BC, Gazola F, Pereira GD, Nakanishi MK, Kunz RI, et al. Ação da estimulação elétrica nervosa transcutânea sobre o limiar de dor induzido por pressão. Rev Dor. 2011;12(3):231–234.
    1. Morgan CR, Santos FS. Estudo da estimulação elétrica nervosa transcutânea (TENS) nível sensório para efeito de analgesia em pacientes com osteoartrose de joelho. Fisioter Mov. 2011;24(4):637–646.
    1. Chen CC, Johnson MI. An investigation into the hypoalgesic effects of high- and low-frequency transcutaneous electrical nerve stimulation (TENS) on experimentally-induced blunt pressure pain in healthy human participants. J Pain. 2010;11(1):53–61.
    1. Resende MA, Sabino GG, Cândido CR, Pereira LS, Francischi JN. Local transcutaneous electrical stimulation (TENS) effects in experimental inflammatory edema and pain. Eur J Pharmacol. 2004;504(3):217–222.
    1. Morimoto HC, Yonekura MY, Liebano RE. Estimulação elétrica nervosa transcutânea nas modalidades convencional e acupuntura na dor induzida pelo frio. Fisioter Pesq. 2009;16(2):148–154.
    1. Fryer G, Morris T, Gibbons P. The relation between thoracic paraspinal tissues and pressure sensitivity measured by a digital algometer. J Osteopath Med. 2004;7(2):64–69.
    1. Claydon LS, Chesterton LS, Barlas P, Sim J. Dose-specific effects of transcutaneous electrical nerve stimulation (TENS) on experimental pain: a systematic review. Clin J Pain. 2011;27(7):635–647.
    1. Pereira GD, Cassolato KM, Lazarin PH, Canto TO, Portolez JL, Bertolini GR. Efeito da corrente interferencial, 2000 Hz, no limiar de dor induzida. Rev Bras Med Esporte. 2011;17(4):257–260.
    1. Orange FA, Amorim MM, Lima L. Uso da eletroestimulação transcutânea para alívio da dor durante o trabalho de parto em uma maternidade-escola: ensaio clínico controlado. Rev Bras Ginecol Obstet. 2003;25(1):45–52.
    1. Santos PC, Ramos JL, Motta MA, Montenegro EJ. Efeitos da TENS acupuntural no limiar da dor induzida pelo frio. Fisioter Mov. 2008;21(4):43–49.
    1. Claydon LS, Chesterton LS, Barlas P, Sim J. Alternating-frequency TENS effects on experimental pain in healthy human participants: a randomized placebo-controlled trial. Clin J Pain. 2013;29(6):533–539.
    1. Lazarou L, Kitsios A, Lazarou I, Sikaras E, Trampas A. Effects of intensity of Transcutaneous Electrical Nerve Stimulation (TENS) on pressure pain threshold and blood pressure in healthy humans. A randomized, double-blind, placebo-controlled trial. Clin J Pain. 2009;25(9):773–780.
    1. Farias RS, Melo RS, Machado YF, Lima FM, Andrade PR. O uso da Tens, crioterapia e criotens na resolução da dor. Rev Bras Ciênc Saúde. 2010;14(1):27–36.
    1. Moran F, Leonard T, Hawthorne S, Hughes CM, McCrum-Gardner E, Johnson MI, et al. Hypoalgesia in response to transcutaneous electrical nerve stimulation (TENS) depends on stimulation intensity. J Pain. 2011;12(8):929–935.
    1. Claydon LS, Chesterton LS, Barlas P, Sim J. Effects of simultaneous dual-site TENS stimulation on experimental pain. Eur J Pain. 2008;12(6):696–704.
    1. Pantaleão MA, Laurino MF, Gallego NL, Cabral CM, Rakel B, Vance C, et al. Adjusting pulse amplitude during transcutaneous electrical nerve stimulation (TENS) application produces greater hypoalgesia. J Pain. 2011;12(5):581–590.
    1. Palmeira CC, Ashmawi HA, Posso Ide P. Sexo e percepção da dor e analgesia. Rev Bras Anestesiol. 2011;61(6):814–828.
    1. Liebano RE, Rakel B, Vance CG, Walsh DM, Sluka KA. An investigation of the development of analgesic tolerance to TENS in humans. Pain. 2011;152:2):335–2):342.

Source: PubMed

3
Abonneren