Effectiveness and Safety of the Dexcom™ G4 Continuous Glucose Monitoring System in Pediatric Subjects With Diabetes Mellitus
Effectiveness and Safety of the Dexcom™ G4 Continuous Glucose Monitoring System in Pediatric Subjects With Diabetes Mellitus.
The primary objective of the study is to evaluate the safety and effectiveness of the G4 System (System) when used as an adjuvant to blood glucose testing over a 7-day period in pediatric subjects with diabetes mellitus.
System effectiveness will be primarily evaluated with comparison to laboratory reference Yellow Springs Instrument (YSI) venous sample measurements. The system performance will be evaluated in terms of point and rate accuracy of the system in reference to YSI. The point accuracy is measured as the proportion of G4 System values that are within ±20% of YSI reference value for glucose levels >80 mg/dL and ±20 mg/dL at YSI glucose levels <80 mg/dL. The trend accuracy of the device performance, i.e., continuous glucose error grid analysis, will be evaluated as well as the temporal accuracy at different glucose rates of changes and different glucose ranges (hypoglycemic, euglycemic, and hyperglycemic ranges). The primary matched paired (Sensor-YSI) measurements will be collected during one in-clinic session. System effectiveness will also be evaluated with SMBG measurements similarly.
Safety data of the system will also be collected and safety will be characterized by the incidence of Adverse Device Effects (ADE) experienced by study participants.
Other objectives include the evaluation of device performance at an alternate site (the upper buttocks).
Visão geral do estudo
Status
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
California
-
Escondido, California, Estados Unidos, 92026
- Advanced Metabolic Care and Research
-
Orange, California, Estados Unidos, 92868
- CHOC Children's
-
Stanford, California, Estados Unidos, 94305
- Stanford University
-
-
Colorado
-
Aurora, Colorado, Estados Unidos, 80045
- Barbara Davis Center
-
-
Idaho
-
Idaho Falls, Idaho, Estados Unidos, 83404
- Rocky Mountain Diabetes and Osteoporosis Center, PA
-
-
Massachusetts
-
Boston, Massachusetts, Estados Unidos, 02215
- Joslin Diabetes Center
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Ages 2 to 17 years ;
- Diagnosis of diabetes mellitus;
- Willing to participate in one 7-day Sensor wear period;
- Willing to wear 2 systems simultaneously;
- Willing to take a minimum of 7 fingersticks per day during home use with a blood glucose meter provided;
- Willing to attend one in-clinic session of up to 6 hours duration. Clinic procedures where blood sampling via SMBG and/or venous YSI method, depending on age;
- Subject or guardian is able to speak, read, and write English.
Exclusion Criteria:
- Extensive skin changes/diseases at sensor wear site that preclude wearing the Sensor on normal skin (e.g. extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis);
- Known allergy to medical-grade adhesives;
- Require a magnetic resonance imaging (MRI) scan, computed tomography (CT) scan, or diathermy during the wear period. If any of these procedures are required urgently during the study, subjects will notify the study staff, end their continuous glucose monitoring (CGM) session, and remove their sensor.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
---|
Pediatric subjects with diabetes mellitus
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
System Performance Effectiveness
Prazo: 7 days
|
The primary objective is to characterize System effectiveness in comparison with the laboratory reference YSI venous sample measurements.
|
7 days
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
System Performance at Alternate Wear Site
Prazo: 7 days
|
An additional objective is to evaluate System performance at an alternate wear site.
The System performance will be assessed, using the same statistical methodology as the primary wear site.
|
7 days
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- PTL900803
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .