- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT03746496
POC Analysis of IO Blood Samples Within Critically Ill Patients
Point-of-care Analyses of Intraosseous Blood Samples Within Critically Ill Patients
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Intravenous access is sometimes difficult to achieve due to vasoconstriction or centralization of circulation. Feasible IO-access with power-driven device is a standard alternative method of vascular access for critically ill patients. It is still unclear whether results of IO samples agree with venous or arterial blood samples so that they could be used in clinical decision-making.
After intraosseous access has been established for fluid resuscitation or medication, a common practice is to aspirate a small amount of blood to verify the proper location of the IO-needle.
POC-testing can provide emergency physicians or paramedics with important information about the patients. Could bone marrow samples be used for POC-testing instead of arterial or venous blood for emergency treatment decision-making or patient allocation?
Several animal and human studies have been published to investigate the correlation between IO versus venous or arterial blood values. Investigators of this study have performed a study in healthy volunteers and discovered that there is a good agreement for some laboratory parameters (pH, gluc, lact), but for K the agreement is poor. Our study group has as well performed a study in critically ill animals investigating the agreement during cardiac arrest and resuscitation. Te evidence about critically ill people is still week.
Aim of this study is to analyze the reliability of analysis of IO samples compared to arterial blood samples within critically ill adult emergency patients.
The hypotheses of this study are:
- Principally, it is possible to analyze IO blood samples with a POC device.
- The results are reliable enough to guide emergency treatment.
If both hypotheses prove to be true, the method can be immediately used in emergency medical situations, e.g. in searching for reversible causes of cardiac arrest.
Setting
Prospective, observational study with 35 prehospital emergency patients. The IO-samples are collected from the small amount of blood, which is aspirated from intraosseous space to confirm the correct needle placement. The IO needles are inserted to the patients for emergency treatment, not because of the study. Critically ill patients, to whom emergency doctors are inserting an intraosseous needle for emergency fluid or drug treatment, are included in the study.
Samples will be analyzed by using an i-STAT point of care analyzer (i-STAT® handheld, Abbot Point of Care Inc. U.S.A) using CG8+ cartridges to analyse Hb, Na, K, pH, pCO2, pO2, TCO2, HCO3, BE, and SpO2. The reliability of the results comparing the IO and arterial samples will be tested with Bland-Altman method by calculating the bias with 95% confidence intervals.
Ethical issues
The ethical committee of Medical Faculty of University of Helsinki has approved the research. Informed consent is waived.
Time plan
The samples will be collected during years 2017 - 2019. The analysis will be performed in the end of the year 2019.
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
-
Vantaa, Finlândia
- FinnHEMS10, Emergency Medicine and Services, Helsinki University Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- need for point-of-care analysis
- need for intraosseous access
Exclusion Criteria:
- cardiac arrest
- ability to understand the consent issues in Finnish, Swedish or English
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
pre-hospital emergency patients
Patient in a need of an IO-access.
Patient in a need of point-of-care laboratory analysis.
Over 18 years.
Alive (no Cardiac arrest.)
|
POC analysis with i-STAT POC analyser from the intraosseous and arterial blood
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
agreement between intraosseous (IO) and arterial POC analyses
Prazo: Samples are analysed immediately after the sample has been taken. Statistical analysis about the agreement performed when the whole data has been collected.
|
agreement analysed with Bland-Altman method from IO and arterial blood samples, which have been analysed with iSTAT point-of care analyser for following parameters: Hb, pH, BE, HCO3, pO2, pCO2, glucose, Na, K, iCa
|
Samples are analysed immediately after the sample has been taken. Statistical analysis about the agreement performed when the whole data has been collected.
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Jouni Nurmi, M.D. Ph D, University of Helsinki, Helsinki University hospital
Publicações e links úteis
Publicações Gerais
- Jousi M, Laukkanen-Nevala P, Nurmi J. Analysing blood from intraosseous access: a systematic review. Eur J Emerg Med. 2019 Apr;26(2):77-85. doi: 10.1097/MEJ.0000000000000569.
- Jousi M, Saikko S, Nurmi J. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses. Scand J Trauma Resusc Emerg Med. 2017 Sep 11;25(1):92. doi: 10.1186/s13049-017-0435-4.
- Backman S, Angerman-Haasmaa S, Jousi M, Siitonen S, Salmela K. ABO and D typing and alloantibody screening in marrow samples: relevance to intraosseous blood transfusion. Transfusion. 2018 Jun;58(6):1372-1376. doi: 10.1111/trf.14557. Epub 2018 Mar 1.
- Tallman CI, Darracq M, Young M. Analysis of intraosseous blood samples using an EPOC point of care analyzer during resuscitation. Am J Emerg Med. 2017 Mar;35(3):499-501. doi: 10.1016/j.ajem.2016.12.005. Epub 2016 Dec 12.
- Veldhoen ES, de Vooght KM, Slieker MG, Versluys AB, Turner NM. Analysis of bloodgas, electrolytes and glucose from intraosseous samples using an i-STAT((R)) point-of-care analyser. Resuscitation. 2014 Mar;85(3):359-63. doi: 10.1016/j.resuscitation.2013.12.002. Epub 2013 Dec 31.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 1234567890
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .