Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Evaluation of Balloon Guide Catheter as Proximal Protection During Carotid Artery Stenting (EMBO-PROTECT) (EMBO-PROTECT)

4 de maio de 2026 atualizado por: Instituto de Investigación Marqués de Valdecilla

Evaluation of Balloon Guide Catheter as Proximal Protection During Carotid Artery Stenting: A Randomized Study (EMBO-PROTECT)

Carotid angioplasty and stenting (CAS) is an effective treatment for carotid artery stenosis but carries a risk of cerebral embolization. This prospective randomized study evaluates the safety and efficacy of proximal embolic protection using a balloon guide catheter during CAS by comparing the incidence of diffusion-weighted MRI-detected microembolisms and symptomatic thromboembolic events between protected and unprotected procedures.

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Estimado)

126

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Age ≥ 18 years
  • Symptomatic or asymptomatic carotid artery stenosis
  • Candidate for carotid artery stenting
  • Written informed consent provided

Exclusion Criteria:

  • Vascular anatomy unsuitable for balloon guide catheter placement
  • Severe renal failure
  • Previous disabling stroke or symptomatic intracranial hemorrhage
  • Evidence of carotid thrombus
  • Severe common carotid artery lesion
  • Chronic atrial fibrillation on oral anticoagulation
  • Acute coronary syndrome within 30 days
  • Contraindications to anticoagulant or antiplatelet therapy
  • Contraindications to MRI
  • Contrast media allergy
  • Lack of prior dual antiplatelet therapy

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: carotid artery stenting with proximal embolic protection using a balloon guide catheter
Carotid artery stenting with proximal embolic protection using a balloon guide catheter.
Comparador Ativo: ratio to carotid artery stenting without proximal embolic protection using a balloon guide catheter.
Carotid artery stenting without proximal embolic protection

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
Incidence, number, and volume of new cerebral ischemic lesions detected by diffusion-weighted MRI within 48 hours after carotid artery stenting
Prazo: Within 48 hours after the procedure
Within 48 hours after the procedure

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Incidence of symptomatic thromboembolic events (stroke or transient ischemic attack) within 30 days
Prazo: During the procedure and within 30 days after the intervention
During the procedure and within 30 days after the intervention
Incidence of myocardial infarction or death within 30 days
Prazo: 30days
30days
Technical success of carotid artery stenting procedure
Prazo: 30days
Technical success defined as successful deployment of the stent with residual stenosis <30% and restoration of adequate blood flow without the need for conversion to another technique.
30days
Correlation between DW-MRI findings and clinical outcomes
Prazo: 30 days
30 days

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de julho de 2026

Conclusão Primária (Estimado)

1 de julho de 2027

Conclusão do estudo (Estimado)

31 de dezembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

26 de março de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

4 de maio de 2026

Primeira postagem (Real)

8 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

8 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

4 de maio de 2026

Última verificação

1 de maio de 2026

Mais Informações

Termos relacionados a este estudo

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever