- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT07576790
Evaluation of Balloon Guide Catheter as Proximal Protection During Carotid Artery Stenting (EMBO-PROTECT) (EMBO-PROTECT)
4. maj 2026 opdateret af: Instituto de Investigación Marqués de Valdecilla
Evaluation of Balloon Guide Catheter as Proximal Protection During Carotid Artery Stenting: A Randomized Study (EMBO-PROTECT)
Carotid angioplasty and stenting (CAS) is an effective treatment for carotid artery stenosis but carries a risk of cerebral embolization.
This prospective randomized study evaluates the safety and efficacy of proximal embolic protection using a balloon guide catheter during CAS by comparing the incidence of diffusion-weighted MRI-detected microembolisms and symptomatic thromboembolic events between protected and unprotected procedures.
Studieoversigt
Status
Ikke rekrutterer endnu
Intervention / Behandling
Undersøgelsestype
Interventionel
Tilmelding (Anslået)
126
Fase
- Ikke anvendelig
Kontakter og lokationer
Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.
Studiekontakt
- Navn: veronica vidal
- Telefonnummer: 942203389
- E-mail: veronica.vidal@idival.org
Undersøgelse Kontakt Backup
- Navn: lucia lavin
- E-mail: lucia.lavin@idival.org
Deltagelseskriterier
Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Ingen
Beskrivelse
Inclusion Criteria:
- Age ≥ 18 years
- Symptomatic or asymptomatic carotid artery stenosis
- Candidate for carotid artery stenting
- Written informed consent provided
Exclusion Criteria:
- Vascular anatomy unsuitable for balloon guide catheter placement
- Severe renal failure
- Previous disabling stroke or symptomatic intracranial hemorrhage
- Evidence of carotid thrombus
- Severe common carotid artery lesion
- Chronic atrial fibrillation on oral anticoagulation
- Acute coronary syndrome within 30 days
- Contraindications to anticoagulant or antiplatelet therapy
- Contraindications to MRI
- Contrast media allergy
- Lack of prior dual antiplatelet therapy
Studieplan
Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: carotid artery stenting with proximal embolic protection using a balloon guide catheter
|
Carotid artery stenting with proximal embolic protection using a balloon guide catheter.
|
|
Aktiv komparator: ratio to carotid artery stenting without proximal embolic protection using a balloon guide catheter.
|
Carotid artery stenting without proximal embolic protection
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Incidence, number, and volume of new cerebral ischemic lesions detected by diffusion-weighted MRI within 48 hours after carotid artery stenting
Tidsramme: Within 48 hours after the procedure
|
Within 48 hours after the procedure
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Incidence of symptomatic thromboembolic events (stroke or transient ischemic attack) within 30 days
Tidsramme: During the procedure and within 30 days after the intervention
|
During the procedure and within 30 days after the intervention
|
|
|
Incidence of myocardial infarction or death within 30 days
Tidsramme: 30days
|
30days
|
|
|
Technical success of carotid artery stenting procedure
Tidsramme: 30days
|
Technical success defined as successful deployment of the stent with residual stenosis <30% and restoration of adequate blood flow without the need for conversion to another technique.
|
30days
|
|
Correlation between DW-MRI findings and clinical outcomes
Tidsramme: 30 days
|
30 days
|
Samarbejdspartnere og efterforskere
Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.
Datoer for undersøgelser
Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.
Studer store datoer
Studiestart (Anslået)
1. juli 2026
Primær færdiggørelse (Anslået)
1. juli 2027
Studieafslutning (Anslået)
31. december 2027
Datoer for studieregistrering
Først indsendt
26. marts 2026
Først indsendt, der opfyldte QC-kriterier
4. maj 2026
Først opslået (Faktiske)
8. maj 2026
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
8. maj 2026
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
4. maj 2026
Sidst verificeret
1. maj 2026
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- EMBO-PROTECT
- NEXTVAL (Andet bevillings-/finansieringsnummer: IDIVAL)
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Ingen
Studerer et amerikansk FDA-reguleret enhedsprodukt
Ingen
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med balloon guide catheter
-
Abbott Medical DevicesAktiv, ikke rekrutterendeSymptomatisk svær aortastenoseGeorgien, Usbekistan
-
University of Rome Tor VergataAfsluttetDrug coated ballon | Plaque Modifikationsteknik | Koronare kalcificerede læsionerItalien
-
Rede Optimus Hospitalar SAiVascular S.L.U.Ikke rekrutterer endnuVenstre hovedkransarteriestenose | Koronar bifurkationsstenose | Kompleks venstre hovedstamme-bifurkationsstenose
-
MedtronicAktiv, ikke rekrutterendeFistel | Arteriovenøs fistel | Arteriovenøs fistelstenose | Arteriovenøs fistelokklusionForenede Stater
-
The Cleveland ClinicAfsluttetLyskebrokForenede Stater
-
DK Medical Technology (Suzhou) Co., Ltd.Ikke rekrutterer endnuIn-Stent Restenose eller De Novo KoronararterielæsionerKina
-
C. R. BardAfsluttetArterielle okklusive sygdomme | Perifer arteriel sygdom | Perifere vaskulære sygdommeForenede Stater
-
magAssist, Inc.Aktiv, ikke rekrutterende
-
Shanghai Shenqi Medical Technology Co., LtdAfsluttetKoronararteriesygdom | Perkutan koronar intervention (PCI) | Forkalkede koronare læsionerKina