Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Evaluation of Balloon Guide Catheter as Proximal Protection During Carotid Artery Stenting (EMBO-PROTECT) (EMBO-PROTECT)

4 maja 2026 zaktualizowane przez: Instituto de Investigación Marqués de Valdecilla

Evaluation of Balloon Guide Catheter as Proximal Protection During Carotid Artery Stenting: A Randomized Study (EMBO-PROTECT)

Carotid angioplasty and stenting (CAS) is an effective treatment for carotid artery stenosis but carries a risk of cerebral embolization. This prospective randomized study evaluates the safety and efficacy of proximal embolic protection using a balloon guide catheter during CAS by comparing the incidence of diffusion-weighted MRI-detected microembolisms and symptomatic thromboembolic events between protected and unprotected procedures.

Przegląd badań

Typ studiów

Interwencyjne

Zapisy (Szacowany)

126

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • Age ≥ 18 years
  • Symptomatic or asymptomatic carotid artery stenosis
  • Candidate for carotid artery stenting
  • Written informed consent provided

Exclusion Criteria:

  • Vascular anatomy unsuitable for balloon guide catheter placement
  • Severe renal failure
  • Previous disabling stroke or symptomatic intracranial hemorrhage
  • Evidence of carotid thrombus
  • Severe common carotid artery lesion
  • Chronic atrial fibrillation on oral anticoagulation
  • Acute coronary syndrome within 30 days
  • Contraindications to anticoagulant or antiplatelet therapy
  • Contraindications to MRI
  • Contrast media allergy
  • Lack of prior dual antiplatelet therapy

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Pojedynczy

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: carotid artery stenting with proximal embolic protection using a balloon guide catheter
Carotid artery stenting with proximal embolic protection using a balloon guide catheter.
Aktywny komparator: ratio to carotid artery stenting without proximal embolic protection using a balloon guide catheter.
Carotid artery stenting without proximal embolic protection

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Incidence, number, and volume of new cerebral ischemic lesions detected by diffusion-weighted MRI within 48 hours after carotid artery stenting
Ramy czasowe: Within 48 hours after the procedure
Within 48 hours after the procedure

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Incidence of symptomatic thromboembolic events (stroke or transient ischemic attack) within 30 days
Ramy czasowe: During the procedure and within 30 days after the intervention
During the procedure and within 30 days after the intervention
Incidence of myocardial infarction or death within 30 days
Ramy czasowe: 30days
30days
Technical success of carotid artery stenting procedure
Ramy czasowe: 30days
Technical success defined as successful deployment of the stent with residual stenosis <30% and restoration of adequate blood flow without the need for conversion to another technique.
30days
Correlation between DW-MRI findings and clinical outcomes
Ramy czasowe: 30 days
30 days

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 lipca 2026

Zakończenie podstawowe (Szacowany)

1 lipca 2027

Ukończenie studiów (Szacowany)

31 grudnia 2027

Daty rejestracji na studia

Pierwszy przesłany

26 marca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

4 maja 2026

Pierwszy wysłany (Rzeczywisty)

8 maja 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

8 maja 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

4 maja 2026

Ostatnia weryfikacja

1 maja 2026

Więcej informacji

Terminy związane z tym badaniem

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na balloon guide catheter

Subskrybuj