Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Manual Versus Autoflow Ventilation During Anesthesia Inductıon in Geriatric Patients

13 de maio de 2026 atualizado por: Fatma GÜLGÜN KILIÇASLAN, Ankara City Hospital Bilkent

Effects of Manual Versus Autoflow Ventilation During Anesthesia Induction on Cerebral and Peripheral Oxygenation in Geriatric Patients

The objective of this study is to compare the effects of manual ventilation and AutoFlow ventilation, administered during the induction of general anesthesia, on cerebral (s-rSO₂) and peripheral (somatic) oxygenation (p-rSO₂) in geriatric patients.

Visão geral do estudo

Descrição detalhada

Ventilation strategies applied during the induction of general anesthesia have a significant impact on cerebral and peripheral oxygenation in geriatric patients. During the induction phase, respiratory and hemodynamic changes become more pronounced due to age-related physiological alterations such as diminished cardiopulmonary reserve, increased chest wall rigidity, decreased pulmonary elasticity, and impaired cerebral autoregulation. These changes increase the vulnerability of elderly patients to hypoxemia, hypocapnia, and imbalances in oxygen delivery. In particular, even brief episodes of hypoxemia or hypocapnia during induction may adversely affect cerebral oxygenation in this population.

Manual mask ventilation may result in unintentional hyperventilation or hypoventilation, potentially leading to hypocapnia and subsequent disturbances in cerebral oxygenation. In contrast, AutoFlow ventilation provides controlled ventilation with predefined parameters and may ensure more stable oxygen delivery.

This study is designed as a prospective, single-center, randomized controlled trial to compare the effects of manual ventilation and AutoFlow ventilation applied during the induction of general anesthesia on cerebral regional oxygen saturation (s-rSO₂) and peripheral (somatic) regional oxygen saturation (p-rSO₂) in geriatric patients. The primary hypothesis is that AutoFlow ventilation provides more stable cerebral and peripheral oxygenation compared to manual ventilation during the induction period.

The study will be conducted in the General and Oncology Operating Rooms of Ankara Bilkent City Hospital. Patients aged 65 years and older, of both sexes, classified as American Society of Anesthesiologists (ASA) physical status I-III, and scheduled for elective surgery requiring endotracheal intubation under general anesthesia will be included. A total of 106 patients (53 per group) will be enrolled based on power analysis, accounting for a potential 10% data loss.

Upon arrival in the operating room following standard preoperative fasting, demographic data (age, sex, height, weight, body mass index) and clinical characteristics (comorbidities, ASA classification) will be recorded. Standard ASA monitoring, including electrocardiography, non-invasive blood pressure, and pulse oximetry, will be applied. Cerebral and peripheral oxygenation will be continuously monitored using near-infrared spectroscopy (NIRS) with sensors placed bilaterally on the frontal region and on the volar surface of the forearms. Baseline values will be recorded before preoxygenation (T1).

Preoxygenation will be performed using 100% oxygen with a flow rate of 10 L/min until end-tidal oxygen (ETO₂) reaches 85% and plateaus for at least 30 seconds. Measurements at this stage will be recorded as T2.

Anesthesia induction will be standardized using fentanyl (1 µg/kg), lidocaine (1 mg/kg), propofol (2-3 mg/kg), and rocuronium (0.6-1 mg/kg), while maintaining hemodynamic stability within ±20% of baseline values. Following induction, mask ventilation with 100% oxygen will be applied for 2 minutes.

Patients will be randomly assigned using a computer-based block randomization method into two groups: manual ventilation and AutoFlow ventilation. In the manual ventilation group, ventilation will be performed by an experienced anesthesiologist or anesthesia resident using a reservoir bag. In the AutoFlow group, ventilation will be delivered by the anesthesia machine using predefined settings: tidal volume of 6 mL/kg (ideal body weight), respiratory rate of 12 breaths per minute, peak pressure limit of 30 cmH₂O, and positive end-expiratory pressure (PEEP) of 5 cmH₂O.

At the end of the 2-minute ventilation period before laryngoscopy, measurements will be recorded as T3 (post-induction, pre-intubation), including heart rate, mean arterial pressure, s-rSO₂, p-rSO₂, end-tidal carbon dioxide (EtCO₂), and peak inspiratory pressure (PIP). After endotracheal intubation and confirmation of tube placement, mechanical ventilation will be initiated and final measurements will be recorded as T4 (post-intubation).

To ensure standardization, NIRS device settings, including alarm limits, noise-reduction filters, and averaging time (8 seconds), will be kept constant for all patients. Factors that may affect measurements, such as motion artifacts, extremity temperature, arrhythmias, or vasopressor use, will be recorded.

Tipo de estudo

Intervencional

Inscrição (Estimado)

106

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

    • Çankaya
      • Ankara, Çankaya, Turquia (Türkiye), 06800
        • Recrutamento
        • Ankara Bilkent City Hospital Department of Anesthesiology and Reanimation

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Patients aged 65 years and older.
  • Patients scheduled to undergo elective surgery requiring endotracheal intubation under general anesthesia.
  • Patients with an American Society of Anesthesiologists (ASA) physical status of I, II, or III.
  • Volunteer patients who are willing to participate and provide written informed consent.

Exclusion Criteria:

  • Patients with severe heart failure or severe pulmonary disease.
  • Patients with a presence or history of brain tumors or cerebrovascular accidents (CVA/stroke).
  • Patients with impaired cooperation or cognitive dysfunction (e.g., dementia, delirium, Alzheimer's disease).
  • Patients with a known history or preoperative prediction of a difficult airway.
  • Patients with a known allergy to the monitoring sensor materials.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Prevenção
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Group M (Manual Ventilation)
Following the standardized induction of general anesthesia (1 µg/kg fentanyl, 1 mg/kg lidocaine, 2-3 mg/kg propofol, and 0.6-1 mg/kg rocuronium), mask ventilation with 100% oxygen will be manually performed by an experienced anesthesiologist or anesthesia resident. Manual ventilation using a reservoir bag will be maintained for 2 minutes to allow for adequate muscle relaxation prior to intubation.
Patients will receive manual mask ventilation with 100% oxygen using a reservoir bag. This procedure will be performed by an experienced anesthesiologist or anesthesia resident for 2 minutes following the administration of induction agents, allowing for adequate muscle relaxation prior to endotracheal intubation.
Experimental: Group A (AutoFlow Ventilation)
Following the same standardized general anesthesia induction protocol, mask ventilation with 100% oxygen will be mechanically delivered by the anesthesia workstation for 2 minutes. The device will be set to deliver a tidal volume (VT) of 6 mL/kg based on the patient's ideal body weight, a respiratory rate of 12 breaths/minute, a peak inspiratory pressure limit of 30 cmH₂O, and a Positive End-Expiratory Pressure (PEEP) of 5 cmH₂O.
Patients will receive mask ventilation delivered mechanically by the anesthesia workstation. The device will provide 100% oxygen for 2 minutes following the administration of induction agents. The ventilator settings will be standardized to an AutoFlow mode with a tidal volume (VT) of 6 mL/kg (based on ideal body weight), a respiratory rate of 12 breaths/minute, a peak pressure limit of 30 cmH₂O, and a Positive End-Expiratory Pressure (PEEP) of 5 cmH₂O

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Change in Cerebral Regional Oxygen Saturation (s-rSO2)
Prazo: Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Bilateral cerebral regional oxygen saturation will be continuously measured using a Near-Infrared Spectroscopy (NIRS) device (INVOS™ oximeter) with sensors placed on the right and left frontal regions. The changes in s-rSO2 values will be recorded to evaluate the impact of manual versus AutoFlow mask ventilation during the induction of general anesthesia.
Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Change in Peripheral (Somatic) Regional Oxygen Saturation (p-rSO2)
Prazo: Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Bilateral peripheral regional oxygen saturation will be measured using NIRS sensors placed on the volar surfaces of the right and left forearms to evaluate tissue oxygen delivery and peripheral perfusion.
Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Mean Arterial Pressure (MAP)
Prazo: Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Hemodynamic stability will be evaluated by recording Mean Arterial Pressure (MAP) using standard non-invasive monitor. Measurements will be tracked to ensure parameters remain within a ±20% margin of the baseline during induction.
Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Peripheral Oxygen Saturation (SpO2)
Prazo: Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Standard systemic oxygen saturation will be monitored non-invasively via pulse oximetry.
Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
End-Tidal Carbon Dioxide (EtCO2)
Prazo: Post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
The efficacy of the mask ventilation techniques will be evaluated by recording End-Tidal Carbon Dioxide (EtCO2).
Post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Heart Rate
Prazo: Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Hemodynamic stability will be evaluated by recording Heart Rate (HR) using standard non-invasive monitor.
Baseline prior to pre-oxygenation (T1), immediately after pre-oxygenation (T2), post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Peak Inspiratory Pressure (PIP)
Prazo: Post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
The efficacy of the mask ventilation techniques will be evaluated by recording Peak Inspiratory Pressure (PIP).
Post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
Tidal Volume (VT)
Prazo: Post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).
The efficacy of the mask ventilation techniques will be evaluated by recording delivered Tidal Volume (VT).
Post-induction/pre-intubation following 2 minutes of mask ventilation (T3), and immediately post-intubation (T4).

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Diretor de estudo: EYÜP HORASANLI, Professor, Ankara Bilkent City Hospital Department of Anesthesiology and Reanimation

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

13 de maio de 2026

Conclusão Primária (Estimado)

20 de outubro de 2026

Conclusão do estudo (Estimado)

5 de dezembro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

5 de maio de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

8 de maio de 2026

Primeira postagem (Real)

13 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

15 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

13 de maio de 2026

Última verificação

1 de maio de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Manual Mask Ventilation

Se inscrever