Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

"Neutral Head Position" and "Head-lift Position" for Orotracheal Intubation With "Trachway" Intubating Stylet in Adults

17 октября 2016 г. обновлено: Wei-Hung Chan, Tri-Service General Hospital

"Neutral Head Position" and "Head-lift Position" for Orotrachwal Intubation With "Trachway" Intubating Stylet in Adults

The purpose of this study is to investigate two different patient's head and neck positions(neutral head position and head-lift position) for the effectiveness of orotracheal intubation with using the "Clarus Video System (Trachway®)" intubating stylet.

Обзор исследования

Статус

Завершенный

Подробное описание

The sniffing position has traditionally been considered the optimal head position for direct laryngoscopy, However, it may aggravate cervical spine injury. The Trachway® video stylet is an intubating device that may avoid cervical movement during intubation. Nonetheless, the effectiveness of limited neck movement in patients with neutral head or head-lift position using the Trachway® video stylet remains unclear. The purpose of this study was to compare the intubation time of the two positions with the Trachway® video stylet.

Тип исследования

Интервенционный

Регистрация (Действительный)

130

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

      • Taipei, Тайвань, 114
        • Tri-Service General Hospital

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 20 лет до 80 лет (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • patients scheduled for various surgeries requiring general anesthesia with tracheal intubation
  • American Society of Anesthesiologists(ASA) physical status classification I-III

Exclusion Criteria:

  • pneumothorax
  • room air saturation by pulse oximeter saturation less than 96%
  • vocal cord palsy
  • craniofacial anomaly
  • congenital upper airway anomaly
  • upper airway disease
  • cervical spine pathology
  • head and neck tumor status post radiotherapy
  • an increased risk of regurgitation or pulmonary aspiration
  • a history of difficult tracheal intubation

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Уход
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Одинокий

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Head-lift Position
The patients' head was placed in the head-lift position(A 7 cm high pillow was set beneath the patients' head with head in neutral position) and then the patient was intubated with Trachway by single-handed chin lift technique
A 7 cm high pillow was set beneath the patients' head with head in neutral position for intubation.
A 7 cm high pillow was set beneath the patients' head with head in neutral position for intubation.
Без вмешательства: Neutral Position
The patients' head was placed in the neutral position and then the patient was intubated with Trachway by single-handed chin lift technique

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Intubation Time
Временное ограничение: from the intubating stylet touched the mouth to the capnogram shown, up to 30 seconds, and the sum of all attempts
the interval from the intubating stylet touched the mouth to capnogram shown, with all attempts, and was recorded by an independent observer with a stop watch.
from the intubating stylet touched the mouth to the capnogram shown, up to 30 seconds, and the sum of all attempts

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Modified Cormack-Lehane Grade
Временное ограничение: during intubation, after epiglottis was identified on the video monitor

The laryngeal view was graded by the observer with modified Cormack-Lehane grade after epiglottis was identified on the video monitor.

Scale range (1, 2, 3, 4). Grade 1 is considered to be a better outcome while grade 4 is considered to be a worse outcome.

during intubation, after epiglottis was identified on the video monitor
Mean Arterial Pressure
Временное ограничение: before and after intubation, up to 5 minutes
compare the mean arterial pressure between two groups.
before and after intubation, up to 5 minutes
Visual Analog Scale of Sore Throat
Временное ограничение: after anesthesia emergence 30 minutest, at post-anesthesia care unit

All patients were asked to rate the degree of sore throat, using a visual analogue scale after anesthesia emergence in the post-anesthesia care unit.

Scale range: 0-10. 0 is considered to be a better outcome while 10 is a worse outcome.

after anesthesia emergence 30 minutest, at post-anesthesia care unit

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования

1 декабря 2014 г.

Первичное завершение (Действительный)

1 октября 2015 г.

Завершение исследования (Действительный)

1 октября 2015 г.

Даты регистрации исследования

Первый отправленный

13 октября 2015 г.

Впервые представлено, что соответствует критериям контроля качества

16 октября 2015 г.

Первый опубликованный (Оценивать)

19 октября 2015 г.

Обновления учебных записей

Последнее опубликованное обновление (Оценивать)

9 декабря 2016 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

17 октября 2016 г.

Последняя проверка

1 октября 2016 г.

Дополнительная информация

Термины, связанные с этим исследованием

Ключевые слова

Другие идентификационные номера исследования

  • 2-103-05-125

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться