The Validity of Peripheral Perfusion Index to Predict Fluid Responsiveness
The Validity of Peripheral Perfusion Index to Predict Fluid Responsiveness Using Mini-fluid Challenge Test
Обзор исследования
Статус
Условия
Подробное описание
The concept of fluid responsiveness has been suggested to guide fluid administration in critically ill patients to avoid either over or under-transfusion.
Several methods have been suggested to detect fluid responsiveness. Mini fluid challenge with concomitant monitoring of stroke volume is one of the most robust methods for pre-load challenge.
The main foreshortening of mini fluid challenge method is the need for a real-time cardiac output monitor, to track the instantaneous change of stroke vole with changing body position. Finding a surrogate to cardiac output to trace the effect of mini fluid challenge would make the test more applicable without the need for advanced hemodynamic monitors.
There is a growing interest in the use of perfusion indices in assessment of fluid responsiveness. Perfusion indices are measures for adequacy of oxygen delivery in peripheral tissues; thus, they were hypothesized to be possible surrogates of cardiac output. Peripheral perfusion index represents "the ratio between the pulsatile and non-pulsatile component of the light reaching the pulse oximeter" . Peripheral perfusion index has been considered as a numerical non-invasive measure for peripheral perfusion. PPI has the advantage over other perfusion indices that it a non-invasive, user-friendly monitor.
The aim of this work is to investigate the ability of peripheral perfusion index to predict the hemodynamic response to mini-fluid challenge in patients with septic shock.
Mini-fluid challenge test will be performed by infusion of 200 mL Lactated Ringer's solution over 1 minute. Velocity time integral will be monitored using Transthoracic echocardiography at the left ventricular outflow tract at the apical five-chamber view. Cardiac output will be calculated, and the patient will be considered fluid-responder if cardiac output increased by 10% after fluid challenge.
Тип исследования
Регистрация (Действительный)
Контакты и местонахождение
Места учебы
-
-
-
Cairo, Египет, 11432
- Ahmed Mohamed Hasanin
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- Septic shock patients
Exclusion Criteria:
- Evident blood loss
- Peripheral vascular disorders
- Upper limb injury or burns
Учебный план
Как устроено исследование?
Детали дизайна
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Peripheral perfusion index
Временное ограничение: 2 hours
|
It is a number describing the ratio between pulsatile and non-pulsatile blood flow measured by pulse oximeter.
It is measured in percent.
with the best value of 20% and the worst value of 0.1%
|
2 hours
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Velocity time integral
Временное ограничение: 2 hours
|
it is a parameter measured from Doppler across the left ventricular outflow tract.
It is calculated by dividing the blood velocity by time and measured in cm
|
2 hours
|
|
Mean arterial blood pressure
Временное ограничение: 2 hours
|
Mean arterial blood pressure measured in mmHg
|
2 hours
|
|
Central venous pressure
Временное ограничение: 2 hours
|
Central venous pressure measured from a central venous catheter.
It is measured in cmH2o
|
2 hours
|
|
Systolic arterial blood pressure
Временное ограничение: 2 hours
|
Systolic arterial blood pressure measured in mmHg
|
2 hours
|
|
Diastolic arterial blood pressure
Временное ограничение: 2 hours
|
Diastolic arterial blood pressure measured in mmHg
|
2 hours
|
|
Cardiac output
Временное ограничение: 2 hours
|
The amount of blood pumped by the heart in one minute.
it is measured as liters per minute
|
2 hours
|
Соавторы и исследователи
Спонсор
Следователи
- Директор по исследованиям: Ahmed Shash, Professor, Head of department of anesthesia, Cairo University, Egypt
Публикации и полезные ссылки
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- N-138-2018
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .