Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

The Validity of Peripheral Perfusion Index to Predict Fluid Responsiveness

21. desember 2020 oppdatert av: Ahmed Hasanin, Cairo University

The Validity of Peripheral Perfusion Index to Predict Fluid Responsiveness Using Mini-fluid Challenge Test

Fluid therapy is an essential component of the management of patients with acute circulatory failure. Nevertheless, unnecessary administration of fluids in non-responders is harmful. Thus, the concept of fluid responsiveness has been suggested to guide fluid administration in critically ill patients to avoid either over or under-transfusion. The aim of this work is to investigate the ability of peripheral perfusion index to predict the hemodynamic response to mini-fluid challenge in patients with septic shock .

Studieoversikt

Status

Fullført

Forhold

Detaljert beskrivelse

The concept of fluid responsiveness has been suggested to guide fluid administration in critically ill patients to avoid either over or under-transfusion.

Several methods have been suggested to detect fluid responsiveness. Mini fluid challenge with concomitant monitoring of stroke volume is one of the most robust methods for pre-load challenge.

The main foreshortening of mini fluid challenge method is the need for a real-time cardiac output monitor, to track the instantaneous change of stroke vole with changing body position. Finding a surrogate to cardiac output to trace the effect of mini fluid challenge would make the test more applicable without the need for advanced hemodynamic monitors.

There is a growing interest in the use of perfusion indices in assessment of fluid responsiveness. Perfusion indices are measures for adequacy of oxygen delivery in peripheral tissues; thus, they were hypothesized to be possible surrogates of cardiac output. Peripheral perfusion index represents "the ratio between the pulsatile and non-pulsatile component of the light reaching the pulse oximeter" . Peripheral perfusion index has been considered as a numerical non-invasive measure for peripheral perfusion. PPI has the advantage over other perfusion indices that it a non-invasive, user-friendly monitor.

The aim of this work is to investigate the ability of peripheral perfusion index to predict the hemodynamic response to mini-fluid challenge in patients with septic shock.

Mini-fluid challenge test will be performed by infusion of 200 mL Lactated Ringer's solution over 1 minute. Velocity time integral will be monitored using Transthoracic echocardiography at the left ventricular outflow tract at the apical five-chamber view. Cardiac output will be calculated, and the patient will be considered fluid-responder if cardiac output increased by 10% after fluid challenge.

Studietype

Observasjonsmessig

Registrering (Faktiske)

57

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

      • Cairo, Egypt, 11432
        • Ahmed Mohamed Hasanin

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

The study will include septic shock patients undergoing fluid resuscitation. Patients will be enrolled during evaluation of fluid responsiveness.

Beskrivelse

Inclusion Criteria:

  • Septic shock patients

Exclusion Criteria:

  • Evident blood loss
  • Peripheral vascular disorders
  • Upper limb injury or burns

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Peripheral perfusion index
Tidsramme: 2 hours
It is a number describing the ratio between pulsatile and non-pulsatile blood flow measured by pulse oximeter. It is measured in percent. with the best value of 20% and the worst value of 0.1%
2 hours

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Velocity time integral
Tidsramme: 2 hours
it is a parameter measured from Doppler across the left ventricular outflow tract. It is calculated by dividing the blood velocity by time and measured in cm
2 hours
Mean arterial blood pressure
Tidsramme: 2 hours
Mean arterial blood pressure measured in mmHg
2 hours
Central venous pressure
Tidsramme: 2 hours
Central venous pressure measured from a central venous catheter. It is measured in cmH2o
2 hours
Systolic arterial blood pressure
Tidsramme: 2 hours
Systolic arterial blood pressure measured in mmHg
2 hours
Diastolic arterial blood pressure
Tidsramme: 2 hours
Diastolic arterial blood pressure measured in mmHg
2 hours
Cardiac output
Tidsramme: 2 hours
The amount of blood pumped by the heart in one minute. it is measured as liters per minute
2 hours

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Studieleder: Ahmed Shash, Professor, Head of department of anesthesia, Cairo University, Egypt

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

27. januar 2019

Primær fullføring (Faktiske)

25. juni 2019

Studiet fullført (Faktiske)

1. juli 2019

Datoer for studieregistrering

Først innsendt

11. januar 2019

Først innsendt som oppfylte QC-kriteriene

14. januar 2019

Først lagt ut (Faktiske)

15. januar 2019

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

23. desember 2020

Siste oppdatering sendt inn som oppfylte QC-kriteriene

21. desember 2020

Sist bekreftet

1. desember 2020

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • N-138-2018

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Kliniske studier på Septisk sjokk

3
Abonnere