Proclear 1-D Multifocal Nondispensing Study

7 mars 2014 uppdaterad av: CooperVision, Inc.
This study is designed to compare the relative performance related to subjective and objective vision between two multifocal soft contact lenses.

Studieöversikt

Status

Avslutad

Betingelser

Detaljerad beskrivning

The aim of this study was to compare the subjective and objective vision. of Proclear® 1-D Multifocal test lenses (MF) with +0.75D overcorrection of the distance lens power in the nondominant eye compared to the Air Optix® Aqua Multifocal (CIBA VISION) contact lenses in low, Medium and High Add presbyopic subjects (+1.25 to +2.50 inclusive).

Studietyp

Interventionell

Inskrivning (Faktisk)

49

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Indiana
      • Bloomington,, Indiana, Förenta staterna, 47405
        • Clinical Optics Research Lab, Indiana University,

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

40 år till 65 år (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Beskrivning

Inclusion Criteria:

  • Be between 40 and 65 years of age (inclusive)
  • Require a reading addition of +1.25 to +2.50D (inclusive)
  • Spherical distance CL or spectacle prescription between +3.00D and -5.00D(inclusive)
  • Spectacle cylinder less than or equal to 0.75D in both eyes.
  • Currently has a reading add correction in their spectacle or CL habitual correction (e.g. if myope, removes distance correction to read)
  • Normal binocularity (no amblyopia, no strabismus, no habitually uncorrected anisometropia ≥ 2.00D)
  • Have a minimum 2 weeks soft contact lens experience
  • Be able to wear the study lens (e.g. good fit is attained and acceptable subjective comfort and vision for the duration of the study)
  • Able to read, comprehend and sign an informed consent
  • Willing to comply with the wear and study visit schedule
  • Monocular best-corrected distance visual acuity ≥ 20/25 in each eye
  • No gas permeable contact lens wear for 1 month prior to the study

Exclusion Criteria:

To be eligible for the study, each candidate must not present with any of the following

  • Any active corneal infection, injury, inflammation, or ocular abnormality
  • Systemic or ocular allergies, which might interfere with contact lens wear
  • Systemic disease, which might interfere with contact lens wear
  • Ocular disease, which might interfere with contact lens wear
  • Pregnant or lactating
  • Strabismus/amblyopia
  • Habitually uncorrected anisometropia greater than or equal to 2.00 D
  • Subjects who have undergone corneal refractive surgery
  • Subjects with keratoconus or other severe corneal irregularity contraindicating lens wear

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: Randomiserad
  • Interventionsmodell: Crossover tilldelning
  • Maskning: Dubbel

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Aktiv komparator: omafilcon A / PC 1-D MF

omafilcon A (PC 1-D MF) / lotrafilcon B (AIR OPTIX MF)

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.
Andra namn:
  • Proclear Multifocal daily wear soft contact lenses
Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses
Andra namn:
  • Air OPtix Aqua Multifocal extended wear soft contact lenses
Aktiv komparator: lotrafilcon B / Air Optix MF

lotrafilcon B (AIR OPTIX MF) / omafilcon A (PC 1-D MF)

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.
Andra namn:
  • Proclear Multifocal daily wear soft contact lenses
Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses
Andra namn:
  • Air OPtix Aqua Multifocal extended wear soft contact lenses

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Objective Vision Assessments: High Contrast Distance Visual Acuity
Tidsram: After 1 hour of lens wear
Tested with charts distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
After 1 hour of lens wear
Objective Vision Assessments: High Contrast Intermediate Visual Acuity
Tidsram: After 1 hour of lens wear
Tested with charts at intermediate distance (100cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
After 1 hour of lens wear
Objective Vision Assessments: High Contrast Near Visual Acuity
Tidsram: After 1 hour of lens wear
Tested with charts set at near point (40cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
After 1 hour of lens wear

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Subjective Overall Vision: High Contrast Distance Visual Quality
Tidsram: After 1 hour of lens wear
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
After 1 hour of lens wear
Subjective Vision Assessments: High Contrast Intermediate Visual Quality
Tidsram: After 1 hour of lens wear
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
After 1 hour of lens wear
Subjective Vision Assessments: High Contrast Near Visual Quality
Tidsram: After 1 hour of lens wear
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
After 1 hour of lens wear

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Huvudutredare: Peter Kollbaum, OD, PhD, Clinical Optics Research Lab, Indiana University, Bloomington, Indiana, USA

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart

1 februari 2012

Primärt slutförande (Faktisk)

1 maj 2012

Avslutad studie (Faktisk)

1 maj 2012

Studieregistreringsdatum

Först inskickad

2 februari 2012

Först inskickad som uppfyllde QC-kriterierna

2 februari 2012

Första postat (Uppskatta)

6 februari 2012

Uppdateringar av studier

Senaste uppdatering publicerad (Uppskatta)

7 april 2014

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

7 mars 2014

Senast verifierad

1 mars 2014

Mer information

Termer relaterade till denna studie

Nyckelord

Ytterligare relevanta MeSH-villkor

Andra studie-ID-nummer

  • CV-12-02A

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera