Proclear 1-D Multifocal Nondispensing Study

7. marts 2014 opdateret af: CooperVision, Inc.
This study is designed to compare the relative performance related to subjective and objective vision between two multifocal soft contact lenses.

Studieoversigt

Status

Afsluttet

Betingelser

Detaljeret beskrivelse

The aim of this study was to compare the subjective and objective vision. of Proclear® 1-D Multifocal test lenses (MF) with +0.75D overcorrection of the distance lens power in the nondominant eye compared to the Air Optix® Aqua Multifocal (CIBA VISION) contact lenses in low, Medium and High Add presbyopic subjects (+1.25 to +2.50 inclusive).

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

49

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Indiana
      • Bloomington,, Indiana, Forenede Stater, 47405
        • Clinical Optics Research Lab, Indiana University,

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

40 år til 65 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Be between 40 and 65 years of age (inclusive)
  • Require a reading addition of +1.25 to +2.50D (inclusive)
  • Spherical distance CL or spectacle prescription between +3.00D and -5.00D(inclusive)
  • Spectacle cylinder less than or equal to 0.75D in both eyes.
  • Currently has a reading add correction in their spectacle or CL habitual correction (e.g. if myope, removes distance correction to read)
  • Normal binocularity (no amblyopia, no strabismus, no habitually uncorrected anisometropia ≥ 2.00D)
  • Have a minimum 2 weeks soft contact lens experience
  • Be able to wear the study lens (e.g. good fit is attained and acceptable subjective comfort and vision for the duration of the study)
  • Able to read, comprehend and sign an informed consent
  • Willing to comply with the wear and study visit schedule
  • Monocular best-corrected distance visual acuity ≥ 20/25 in each eye
  • No gas permeable contact lens wear for 1 month prior to the study

Exclusion Criteria:

To be eligible for the study, each candidate must not present with any of the following

  • Any active corneal infection, injury, inflammation, or ocular abnormality
  • Systemic or ocular allergies, which might interfere with contact lens wear
  • Systemic disease, which might interfere with contact lens wear
  • Ocular disease, which might interfere with contact lens wear
  • Pregnant or lactating
  • Strabismus/amblyopia
  • Habitually uncorrected anisometropia greater than or equal to 2.00 D
  • Subjects who have undergone corneal refractive surgery
  • Subjects with keratoconus or other severe corneal irregularity contraindicating lens wear

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Dobbelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: omafilcon A / PC 1-D MF

omafilcon A (PC 1-D MF) / lotrafilcon B (AIR OPTIX MF)

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.
Andre navne:
  • Proclear Multifocal daily wear soft contact lenses
Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses
Andre navne:
  • Air OPtix Aqua Multifocal extended wear soft contact lenses
Aktiv komparator: lotrafilcon B / Air Optix MF

lotrafilcon B (AIR OPTIX MF) / omafilcon A (PC 1-D MF)

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.

Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.
Andre navne:
  • Proclear Multifocal daily wear soft contact lenses
Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses
Andre navne:
  • Air OPtix Aqua Multifocal extended wear soft contact lenses

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Objective Vision Assessments: High Contrast Distance Visual Acuity
Tidsramme: After 1 hour of lens wear
Tested with charts distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
After 1 hour of lens wear
Objective Vision Assessments: High Contrast Intermediate Visual Acuity
Tidsramme: After 1 hour of lens wear
Tested with charts at intermediate distance (100cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
After 1 hour of lens wear
Objective Vision Assessments: High Contrast Near Visual Acuity
Tidsramme: After 1 hour of lens wear
Tested with charts set at near point (40cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
After 1 hour of lens wear

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Subjective Overall Vision: High Contrast Distance Visual Quality
Tidsramme: After 1 hour of lens wear
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
After 1 hour of lens wear
Subjective Vision Assessments: High Contrast Intermediate Visual Quality
Tidsramme: After 1 hour of lens wear
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
After 1 hour of lens wear
Subjective Vision Assessments: High Contrast Near Visual Quality
Tidsramme: After 1 hour of lens wear
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
After 1 hour of lens wear

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Peter Kollbaum, OD, PhD, Clinical Optics Research Lab, Indiana University, Bloomington, Indiana, USA

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. februar 2012

Primær færdiggørelse (Faktiske)

1. maj 2012

Studieafslutning (Faktiske)

1. maj 2012

Datoer for studieregistrering

Først indsendt

2. februar 2012

Først indsendt, der opfyldte QC-kriterier

2. februar 2012

Først opslået (Skøn)

6. februar 2012

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

7. april 2014

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

7. marts 2014

Sidst verificeret

1. marts 2014

Mere information

Begreber relateret til denne undersøgelse

Nøgleord

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • CV-12-02A

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med omafilcon A / PC 1-D MF

Abonner