Reduce Ventricular Pacing in Dual Chamber Implantable Cardioverter Defibrillators Using AutoIntrinsic Conduction Search Study
Reduce Ventricular Pacing in Dual Chamber Implantable Cardioverter Defibrillators Using AutoIntrinsic Conduction Search (REDUCE Study)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
New Jersey
-
Pomona, New Jersey, United States
- AtlantiCare Regional Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patient has been implanted with a dual chamber SJM ICD with AICS for 1 month (± 2 weeks).
- At the time of enrollment, patient is paced in the right ventricle (RV) ≤25% of the time as determined by the device diagnostics.
- Patient is medically stable.
Exclusion Criteria:
- Patient has evidence of atrioventricular (AV) block (first, second or third degree) such that ventricular pacing would be required as part of the patient's routine management
- Patient is unable to comply with the follow-up visits due to geographical, psychological, or any other reasons.
- Patient is younger than 18 years of age.
- Patient is pregnant.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: AICS On
Patients in this arm have Autointrinsic conduction search programmed ON.
|
Autointrinsic conduction search is programmed on in those patients randomized to AICS ON.
|
|
No Intervention: AICS Off
Patients assigned to this arm do not have Autointrinsic Conduction Search programmed on.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
The primary endpoint is the percentage of intrinsic ventricular events.
Time Frame: 3 months
|
3 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Number of atrial tachycardia (AT), atrial fibrillation (AF), ventricular tachycardia (VT), and ventricular fibrillation (VF) episodes
Time Frame: 3 months
|
3 months
|
|
Frequency of inappropriate ICD therapy during AT/AF
Time Frame: 3 months
|
3 months
|
|
Frequency of appropriate ICD therapy for VT/VF
Time Frame: 3 months
|
3 months
|
|
Study related adverse events
Time Frame: 3 months
|
3 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Zaffer Syed, MS, Abbott Medical Devices
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CRD292
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.