Data Collection During CT for Axial Flow VADs
Pilot Study of Data Collection During Computerized Tomography (CT) to Determine Accurate Flow Rates for Axial Flow Ventricular Assist Device (VAD) Patients
At present, there is not accurate way to determine specific flow rates for axial flow ventricular assist devices (VADS). If a right heart cath is needed for these patients for clinical purposes, they will also undergo a cardiac CT scan while the pulmonary artery catheter is in place. It is possible to visualize the flow rates of axial flow VAD's and determine a more accurate rate per specific patient.
Data Analyzed with following results:
Article in Press for Cardiopulmonary Support and Physiology, results state "Pairwise comparison of calculated output from left ventricular assist devices is feasible using first pass dynamic computed tomography test bolus technique versus thermodilution output measurements yielded good agreement (P=.03). The output calculated using dynamic CT underestimated the thermodilution output measurement by 0.54+ 0.37 L/min (95% confidence interval 0.66-0.94).
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Ohio
-
Columbus, Ohio, United States, 43210
- The Ohio State University Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Signed Informed consent
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
CCT exam
|
64 slice spiral computerized tomography
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
data collection to help determine better clinical evaluation
Time Frame: ongoing
|
ongoing
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Benjamin Sun, MD, Ohio State University, Division of Cardiothoracic Surgery
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2005H0200
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.