Minimally-invasive Assessment of Cardiac Output in Severe Preeclampsia
Minimally-invasive Assessment of Cardiac Output in Severe Preeclampsia: Radial Artery Wave Form Analysis Versus Trans-thoracic Echocardiogram
Severe preeclampsia often presents with uncontrolled hypertension and therefore requires close monitoring of blood pressure and cardiac performance.
The purpose of the study is to compare two methods of measuring the performance of the heart in pregnant women: one by ultrasound of the heart, the other by assessing the pulse generated in the blood vessel of the wrist. We hope that the method using pulse analysis will be as effective as ultrasound, which is labour intensive and operator dependant.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Severe preeclampsia often presents with uncontrolled hypertension, which requires close monitoring of blood pressure and cardiac output. It will be very useful to know the cardiac output in this patient population, because it will guide the choice of antihypertensive drugs and measure their effect on cardiac output.
Traditionally pulmonary artery catheters were used to measure cardiac output. There are numerous problems with using this method in severe preeclampsia. These include technical difficulty inserting the catheter in an awake, edematous pregnant patient, potentially causing a pneumothorax, damaging the carotid artery or insertion site infection. There is also an increased risk for cardiac arrhythmias. Apart from the risks, the accuracy of the thermodilution measurements can be influenced by factors such as timing of the injection within the respiratory cycle, temperature of the injectate, speed of injection, and placement of the catheter. A readily available, accurate non-invasive cardiac output measurement technique, that will provide reliable data with fewer risks, is needed.
Doppler ultrasound (trans thoracic echocardiography) is the gold standard for measuring cardiac output non-invasively in pregnant patients. Unfortunately the method is operator dependant, not continuous and not always available when needed most.
Recently a device called the FloTrac has been introduced that measures cardiac output minimally invasively. Attached to an arterial line it measures cardiac output every 20 seconds via arterial waveform analysis. The standard of care for measuring blood pressure in severe preeclampsia requires the placement of an intra-arterial line. This group of patients is therefore ideal for measuring cardiac output with the FloTrac, especially since powerful intravenous anti-hypertensives are used to control blood pressure.
Our hypothesis is that the FloTrac will be comparable to Doppler Ultrasound for measuring cardiac output in severely preeclamptic patients.
Study Type
Study Type
Contacts and Locations
Study Locations
-
-
Ontario
-
Toronto, Ontario, Canada, M5G 1X5
- Mount Sinai Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Severe Preeclampsia
- Arterial Line Required
- Candidates for magnesium sulfate, labetalol or hydrazine
Exclusion Criteria:
- Preexisting cardiac disease
Study Plan
How is the study designed?
Design Details
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Jose CA Carvalho, MD PhD, Mount Sinai Hospital
Study record dates
Study Major Dates
Study Start
Study Start
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 07-06
- 07-0078-E
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.