Ologen (OculusGen)-Phacotrabeculectomy Historical Control Study in India
Study of the Safety and Effectiveness of the OculusGenTM Collagen Matrix Implant as an Aid in Phacotrabeculectomy Surgery
- . Study Objective: The objective of this study is to determine the safety and effectiveness of the OculusGenTM Biodegradable Collagen Matrix Implant in phacotrabeculectomy surgery. The primary endpoint is to prove the effectiveness via the reduction of Intraocular Pressure, and the secondary endpoint is to prove the safety via the incidence of complications and adverse events.
- . Study Design: The study is designed as a historical controlled study. Patient who meet the inclusion/exclusion criteria and sign the informed consent form will be included for this study. The allocation of subjects is non-randomized, and there is a single group for assignment.
- . Follow-Up: This investigation is including 7 post-operative visits and follow-up within 6 months from the date of surgery. Patients should be seen at postoperative days 1, 7, 14, 30, 60, 90 and 180. The visit window of ± 7 days is allowed for the 30, 60, 90 and 180 day visits. The further follow-up of subject after trial is continually tracked by the investigator.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Chandigarh, India, 500 034
- Grewal Eye Institute
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Subject inclusion criteria:
- Age 18 years or over.
- At least one eye diagnosed with glaucoma and receiving maximally tolerated medical therapy.
- Visually significant cataract with visual acuity of less than or equal to 6/12.
- Subject able and willing to cooperate with investigation plan.
- Subject willing to sign informed consent form.
Subject exclusion criteria:
- Known allergic reaction to collagen.
- Subject is on Warfarin and discontinuation is not recommended.
- Subject with normal tension glaucoma or aphakic glaucoma.
- Subject with corneal disease.
- Participation in an investigational study during the 30 days proceeding phacotrabeculectomy.
- Ocular infection within 14 days prior to phacotrabeculectomy.
- Pregnant or breast-feeding women.
- Monocular subject.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
OculusGen Collagen Matrix
OculusGen Biodegradable Collagen Matrix Implant in Trabeculectomy.
|
OculusGen Biodegradable Collagen Matrix Implant in Trabeculectomy.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Preoperative and Postoperative Intraocular Pressure
Time Frame: baseline and 90 days
|
The preoperative and postoperative intraocular pressure is measured as mmHg at baseline and 90 days.
|
baseline and 90 days
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Participants With Any Complications or Adverse Events.
Time Frame: 180 day
|
Observation of the incidence of complications, including transient shallow anterior chamber, hyphema, choroidal detachment, hypotony or endophthalmitis.
|
180 day
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: SPS Grewal, MD, Grewal Eye Institute
Publications and helpful links
General Publications
- Chen HS, Ritch R, Krupin T, Hsu WC. Control of filtering bleb structure through tissue bioengineering: An animal model. Invest Ophthalmol Vis Sci. 2006 Dec;47(12):5310-4. doi: 10.1167/iovs.06-0378. Erratum In: Invest Ophthalmol Vis Sci. 2007 Feb;48(2):485.
- Hsu WC, Spilker MH, Yannas IV, Rubin PA. Inhibition of conjunctival scarring and contraction by a porous collagen-glycosaminoglycan implant. Invest Ophthalmol Vis Sci. 2000 Aug;41(9):2404-11.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Mediking 0704
- OculusGen-2007-04-20 (Other Identifier: Aeon Astron Europe B.V.)
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.