FLAIR™ Delivery System Study (FLAIR DS)
A Prospective Observational Study of the FLAIR™ Endovascular Stent Graft Optimized Delivery System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Connecticut
-
Fairfield, Connecticut, United States, 06825
- Connecticut Image Guided Surgery
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- The subject is either a male or non-pregnant female ≥ 18 years old.
- The subject has been properly informed about the study per IRB requirements, and has signed and dated the IRB-approved ICF.
- The subject is willing to comply with the protocol requirements and can be contacted by telephone.
- The subject has a synthetic AV access graft located in an arm that has been implanted for > 30 days and has undergone at least one successful dialysis session prior to the index procedure.
- Angiographic evidence indicates that the subject has a stenosis of >50% located at the graft-vein anastomosis of the subject's synthetic AV access graft.
- The target lesion is estimated to be ≤ 7 cm in length by angiography prior to performance of any interventional procedures.
- The entire target lesion is located within 7 cm of the graft-vein anastomosis, as verified by angiography, such that approximately 1 cm of the FLAIR™ Endovascular Stent Graft will extend into non-diseased vein and approximately 1 cm but no more than 2 cm of the FLAIR™ Endovascular Stent Graft will extend into non-diseased AV graft.
- Graft diameter at the deployment site is between 5 mm and 8 mm, as verified by angiography.
- Full expansion of an appropriately sized angioplasty balloon, in the operator's judgment, can be achieved during primary angioplasty.
Exclusion Criteria:
- The subject has a life expectancy of < 6 months.
- The presence of a previously placed stent and/or stent graft located in the treatment area. The treatment area is defined as the entire target lesion and 1 cm of landing zone into both non-diseased AV graft and non-diseased vein.
- The subject has an infected AV access graft or other infection.
- The location of the target lesion would require that the FLAIR™ Endovascular Stent Graft be deployed fully across the elbow joint.
- The location of the target lesion would require that the FLAIR™ Endovascular Stent Graft cross an angle (between the outflow vein and synthetic AV access graft) that is > 90 degrees.
- The subject has an uncorrected blood coagulation disorder.
- The subject has a known allergy or sensitivity to contrast media which cannot be adequately pre-medicated.
- Subject is currently enrolled or scheduled to be enrolled in other investigations that conflict with follow-up testing or confounds data in this trial.
- The subject has a known hypersensitivity to nickel-titanium.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: FLAIR Endovascular Stent Graft and Delivery System
|
The FLAIR™ Endovascular Stent Graft is designed to treat venous anastomotic stenoses of AV access grafts, providing both structural support of the site following angioplasty (stent), and a barrier to locally recurrent flow-limiting neointimal tissue growth (covering/graft).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Technical Success for Delivery
Time Frame: Measured at the time of implantation (Day 0)
|
defined as deployment of the implant to the intended location, assessed at the time of the index procedure.
|
Measured at the time of implantation (Day 0)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Device/Procedure-related Adverse Events(Safety of Delivery)
Time Frame: Index Procedure to 30 days
|
Device/Procedure-related adverse events from the index procedure through 30 days post procedure
|
Index Procedure to 30 days
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Melvin Rosenblatt, M.D., Connecticut Image Guided Surgery
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- BPV-07-001
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.