Vessel Wall Response of the Zotarolimus Drug-eluting Stent Implanted in AMI Assessed by Optical Coherence Tomography (OCTAMI)
Prospective, Randomized, Controlled Arm Study Comparing the Coverage of the Zotarolimus-eluting Stent vs Bare Metal Stent Implanted in ST- Elevation Myocardial Infarction (STEMI).
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Bergamo, Italy
- Ospedali Riuniti di Bergamo
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Acute Myocardial MI with ST segment Elevation, within 12 hours from symptoms onset
- Native coronary artery disease with >70% diameter stenosis (no prior stent implant, no prior brachytherapy)
- Vessel size in between 2.5 and 3.75 mm
- Signed patient informed consent
Exclusion Criteria:
- Lesions in coronary artery bypass grafts
- Significant left main disease
- Killip class IV
- Reecent major bleeding (6 months)
- Renal failure with creatinine value > 2.5 mg/dl
- Allergy to aspirin and or clopidogrel/ticlopidine
- Patient in anticoagulant therapy
- IMA due to a stent thrombosis
- No suitable anatomy for OCT scan: (only ostial location, very tortuous anatomy, very distal or large vessels [≥ 3.75 mm in diameter])
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: DES - Zotarolimus Drug eluting stents
Zotarolimus Drug eluting stents in overlap
|
ENDEAVOR® drug-eluting stent implanted in acute myocardial infarction
Comparison of Drug Eluting versus Bare Metal Stent
Other Names:
|
|
ACTIVE_COMPARATOR: BMS -Bare metal stent
Bare metal stent
|
DRIVER bare metal stent implanted in acute myocardial infarction
Comaprison between Drug Eluting and Bare Metal Coronary Stents
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Non inferiority OCT Number of uncovered Stent struts for Endeavor drug eluting stent vs Driver BMSbare metal stent
Time Frame: 6 months
|
Non inferiority
|
6 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
number of well apposed stent struts without neointima
Time Frame: 6 months
|
number of well apposed stent struts without neointima
|
6 months
|
|
number of malapposed stent struts without neointima
Time Frame: 6 months
|
number of malapposed stent struts without neointima
|
6 months
|
|
number of sections with > 30% uncovered struts/total struts
Time Frame: 6 months
|
number of sections with > 30% uncovered struts/total struts
|
6 months
|
|
Number of sections with incomplete strut apposition
Time Frame: 6 months
|
Number of sections with incomplete strut apposition
|
6 months
|
|
Adjudicated MACE(Death, re-MI, TLR) rate at 30 days and 6 months (non inferiority)
Time Frame: 6 months
|
Adjudicated MACE(Death, re-MI, TLR) rate at 30 days and 6 months (non inferiority)
|
6 months
|
|
In segment OCT neontimal volume
Time Frame: 6 months
|
In segment OCT neontimal volume
|
6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Luscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, Virmani R. Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation. 2007 Feb 27;115(8):1051-8. doi: 10.1161/CIRCULATIONAHA.106.675934.
- Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, Kukreja N, Juni P, Sianos G, Hellige G, van Domburg RT, Hess OM, Boersma E, Meier B, Windecker S, Serruys PW. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet. 2007 Feb 24;369(9562):667-78. doi: 10.1016/S0140-6736(07)60314-6.
- Kindermann M, Adam O, Werner N, Bohm M. Clinical Trial Updates and Hotline Sessions presented at the European Society of Cardiology Congress 2007: (FINESSE, CARESS, OASIS 5, PRAGUE-8, OPTIMIST, GRACE, STEEPLE, SCAAR, STRATEGY, DANAMI-2, ExTRACT-TIMI-25, ISAR-REACT 2, ACUITY, ALOFT, 3CPO, PROSPECT, EVEREST, COACH, BENEFiT, MERLIN-TIMI 36, SEARCH-MI, ADVANCE, WENBIT, EUROASPIRE I-III, ARISE, getABI, RIO). Clin Res Cardiol. 2007 Nov;96(11):767-86. doi: 10.1007/s00392-0591-z. Epub 2007 Oct 25.
- Kastrati A, Dibra A, Spaulding C, Laarman GJ, Menichelli M, Valgimigli M, Di Lorenzo E, Kaiser C, Tierala I, Mehilli J, Seyfarth M, Varenne O, Dirksen MT, Percoco G, Varricchio A, Pittl U, Syvanne M, Suttorp MJ, Violini R, Schomig A. Meta-analysis of randomized trials on drug-eluting stents vs. bare-metal stents in patients with acute myocardial infarction. Eur Heart J. 2007 Nov;28(22):2706-13. doi: 10.1093/eurheartj/ehm402. Epub 2007 Sep 27.
- Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol. 2006 Jul 4;48(1):193-202. doi: 10.1016/j.jacc.2006.03.042. Epub 2006 May 5.
- Nakazawa G, Finn AV, John MC, Kolodgie FD, Virmani R. The significance of preclinical evaluation of sirolimus-, paclitaxel-, and zotarolimus-eluting stents. Am J Cardiol. 2007 Oct 22;100(8B):36M-44M. doi: 10.1016/j.amjcard.2007.08.020.
- Fajadet J, Wijns W, Laarman GJ, Kuck KH, Ormiston J, Munzel T, Popma JJ, Fitzgerald PJ, Bonan R, Kuntz RE; ENDEAVOR II Investigators. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation. 2006 Aug 22;114(8):798-806. doi: 10.1161/CIRCULATIONAHA.105.591206. Epub 2006 Aug 14.
- Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J. 2007 Apr;28(8):961-7. doi: 10.1093/eurheartj/ehl413. Epub 2006 Nov 29.
- Yamaguchi T, Terashima M, Akasaka T, Hayashi T, Mizuno K, Muramatsu T, Nakamura M, Nakamura S, Saito S, Takano M, Takayama T, Yoshikawa J, Suzuki T. Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting. Am J Cardiol. 2008 Mar 1;101(5):562-7. doi: 10.1016/j.amjcard.2007.09.116. Epub 2008 Jan 10.
- Pinto Slottow TL, Waksman R. Overview of the 2007 Food and Drug Administration Circulatory System Devices Panel meeting on the endeavor zotarolimus-eluting coronary stent. Circulation. 2008 Mar 25;117(12):1603-8. doi: 10.1161/CIRCULATIONAHA.107.752261. No abstract available.
- Guagliumi G, Sirbu V, Bezerra H, Biondi-Zoccai G, Fiocca L, Musumeci G, Matiashvili A, Lortkipanidze N, Tahara S, Valsecchi O, Costa M. Strut coverage and vessel wall response to zotarolimus-eluting and bare-metal stents implanted in patients with ST-segment elevation myocardial infarction: the OCTAMI (Optical Coherence Tomography in Acute Myocardial Infarction) Study. JACC Cardiovasc Interv. 2010 Jun;3(6):680-7. doi: 10.1016/j.jcin.2010.04.005.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 457/2008
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.