RESOLUTE Japan - The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent (RJ)
The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent in De Novo Lesions in Native Coronary Arteries
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Aichi, Japan, 441-8530
- Toyohashi Heart Center
-
Hokkaido, Japan, 041-8680
- Hospital Hakodate Hokkaido
-
Hyogo, Japan, 660-8511
- Kansai Rosai Hospital
-
Kanagawa, Japan, 247-8533
- Shonan Kamakura General Hospital
-
Kanagawa, Japan, 211-8510
- Kanto Rosai Hospital
-
Kanagawa, Japan, 230-0012
- Yokohama Tobu Hospital
-
Kumamoto, Japan, 866-8533
- Kumamoto Rosai Hospital
-
Kyoto, Japan, 615-8256
- Kyoto Katsura Hospital
-
Okayama, Japan, 710-8602
- Kurashiki Central Hospital
-
Tochigi, Japan, 329-0498
- Jichi Medical University Hospital
-
Tokyo, Japan, 173-8606
- Teikyo University Hospital
-
Tokyo, Japan, 106-0032
- The Cardiovascular Institute Hospital
-
Tokyo, Japan, 142-8666
- Showa University Hospita
-
Tokyo, Japan, 153-6181
- Toho University Medical Center, Ohashi Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Acceptable candidate for percutaneous coronary intervention (PCI),stenting, and emergency coronary artery bypass graft surgery
- Clinical evidence of ischemic heart disease, stable or unstable angina, silent ischemia and/or positive functional study
- Informed consent
- Patient agrees to comply with specified follow-up evaluations at same investigational site
- Single target lesion or two target lesions located in separate coronary arteries
- De novo lesion(s) in native coronary artery(ies)
- Target lesion(s) ≤ 27 mm in length
- Target vessel(s) have reference vessel diameter 2.5 mm to 3.5 mm
Exclusion Criteria:
- Within 7 days of implant platelet count <100,000 cells/mm³ or >700,000 cells/mm³; white blood cell (WBC) count <3,000 cells/mm³; serum creatinine level >2.5 mg/dl
- Acute myocadial infarction (MI) within 72 hrs of the index procedure (Q wave myocardial infarction(QWMI) or any elevation of Creatinine Kinase Mycocardial-band Isoemzyme (CK-MB) > lab upper limit of normal)
- Previous PCI of target vessel(s) within 9 months prior to the procedure
- Planned PCI of any vessel within 30 days post-index procedure and/or planned PCI of target vessel(s) within 12 months post-index procedure
- History of stroke or transient ischemic attack (TIA) within prior 6 months
- Participating in investigational drug/device study that has not completed primary endpoint or interferes with study endpoints
- Inability to comply with required trial antiplatelet regimen
- Previous stent in target vessel unless it has been at least 9 months since stent placed and target lesion(s) is/are at least 15 mm from previous stent
- Target vessel(s) has/have other lesions w/ > 40% diameter stenosis
- Unprotected left main coronary artery disease
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Drug Eluting Stent
All patients may have one or two lesions, if the two lesions are located in separate coronary arteries.
A patient with one or two lesions treated with stents of diameter 2.5mm - 3.5mm will be designated in this study.
|
Implantation of a MDT-4107 Zotarolimus-Eluting Coronary Stent
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
In-stent Late Lumen Loss (LLL)
Time Frame: Post procedure, 8 Months
|
The difference between the post-procedure immediate minimal lumen diameter (MLD) and follow up angigraphy MLD
|
Post procedure, 8 Months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percent of Patient With Target Lesion Failure(Major Secondary Endpoint)
Time Frame: 12 months
|
Major Secondary Endpoint Target lesion fature (TLF) is defined as cardiac death, target vessel myocardial infarction(Q wave and non-Q wave), or clinically-driven target lesion revascularization (TLR) by percutaneous or surgical methods.
|
12 months
|
|
Success(Device, Lesion, Procedure), Major Adverse Cardiac Events (MACE), Target Vessel Failure (TVF), and Stent Thrombosis
Time Frame: 12 months
|
12 months
|
|
|
Rates of Incomplete Stent Apposition, Neointimal Hyperplastic Volume and Percent Volume Obstruction (%VO)
Time Frame: 8 months
|
8 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Saito S, Maehara A, Vlachojannis GJ, Parise H, Mehran R; RESOLUTE Japan Investigators. Clinical and angiographic evaluation of the resolute zotarolimus-eluting coronary stent in Japanese patients - long-term outcome in the RESOLUTE Japan and RESOLUTE Japan small vessel study. Circ J. 2015;79(1):96-103. doi: 10.1253/circj.CJ-14-0836. Epub 2014 Nov 27.
- Silber S, Kirtane AJ, Belardi JA, Liu M, Brar S, Rothman M, Windecker S. Lack of association between dual antiplatelet therapy use and stent thrombosis between 1 and 12 months following resolute zotarolimus-eluting stent implantation. Eur Heart J. 2014 Aug 1;35(29):1949-56. doi: 10.1093/eurheartj/ehu026. Epub 2014 Feb 7.
- Silber S, Serruys PW, Leon MB, Meredith IT, Windecker S, Neumann FJ, Belardi J, Widimsky P, Massaro J, Novack V, Yeung AC, Saito S, Mauri L. Clinical outcome of patients with and without diabetes mellitus after percutaneous coronary intervention with the resolute zotarolimus-eluting stent: 2-year results from the prospectively pooled analysis of the international global RESOLUTE program. JACC Cardiovasc Interv. 2013 Apr;6(4):357-68. doi: 10.1016/j.jcin.2012.11.006. Epub 2013 Mar 20.
- Farooq V, Vranckx P, Mauri L, Cutlip DE, Belardi J, Silber S, Widimsky P, Leon M, Windecker S, Meredith I, Negoita M, van Leeuwen F, Neumann FJ, Yeung AC, Garcia-Garcia HM, Serruys PW. Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program. Heart. 2013 May;99(9):626-33. doi: 10.1136/heartjnl-2012-303368. Epub 2013 Mar 6.
Helpful Links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- MDT2-07-03
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.