Comparison of Cardiac Computed Tomography and Vasodilator Stress Magnetic Resonance Imaging Perfusion in Patients With Prior Equivocal Stress Test for Detection of Coronary Artery Disease
Background:
- Noninvasive cardiac stress testing is imperfect. Inconclusive test results generate further expensive testing.
- In patients with known or suspected coronary artery disease, both computed tomography (CT) and magnetic resonance imaging (MRI) have been shown to provide suitable results for detecting the disease. However, both types of scans have limitations in their usefulness, and it is not known whether one is preferable in either accuracy or cost-effectiveness.
Objectives:
- To determine the accuracy and cost-effectiveness of CT and MRI in subjects with a prior inconclusive heart stress test.
Eligibility:
- Patients 18 years of age and older who have had an inconclusive heart stress test within the past 90 days.
Design:
- A blood test will be obtained prior to both heart tests. This will require less than a teaspoon of blood.
- A CT scan will be performed, accompanied by beta blocker medications (to slow heart rate) or nitroglycerin (to enlarge blood vessels) to improve picture quality, as needed.
- An MRI scan will be performed. Scans will be taken before, during, and after the patient receives vasodilators (to increase blood flow to the coronary arteries and detect blockages in heart blood vessels).
- Heart rate and function will be monitored with an electrocardiogram.
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Maryland
-
Bethesda, Maryland, United States, 20892
- National Institutes of Health Clinical Center, 9000 Rockville Pike
-
Bethesda, Maryland, United States, 20814
- Suburban Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
- GENERAL INCLUSION CRITERIA:
- 18 years of age and older
- Prior equivocal stress study within the preceding 90 days
- Able to provide informed consent
MEDICAL EXCLUSION CRITERIA:
- Decompensated heart failure (unable to lie flat during MRI or CT)
- Severe kidney disease (MDRD estimated Glomerular Filtration Rate less than 30mL/min/1.73m(2).
- Prior cardiac revascularization with coronary stent or bypass surgery
- Resting tachycardia (HR greater than l00 bpm)
- Pregnant women (when uncertain, subjects will undergo urine or blood testing)
- Lactating women (unless they are willing to discard breast milk for 24 hours after receiving gadolinium)
- Second (Type II) and third degree atrioventricular heart block
- Asthma or chronic pulmonary disease (emphysema) actively treated with bronchodilators or leukotriene antagonists
MRI EXCLUSION CRITERIA:
- Cardiac pacemaker or implantable defibrillator
- Cerebral aneurysm clip
- Neural stimulator (e.g. TENS-Unit)
- Any type of ear implant
- Ocular foreign body (e.g. metal shavings)
- Any implanted device (e.g. insulin pump, drug infusion device)
- Metal shrapnel or bullet
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
1
Stress MRI perfusion, and cardiac CT will have observed sensitivity, specificity, and accuracyof at least 0.80 in predicting CAD in a patient population with prior equivocal stress testing.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Stress MRI perfusion, and cardiac CT will have observed sensitivity, specificity, and accuracy of at least 0.80 in predicting CAD in a patient population with prior equivocal stress testing.
Time Frame: end of study
|
estimate the sensitivity, specificity, and accuracy of MRI and CT, for detecting obstructive CAD in patients with a prior equivocal stress study
|
end of study
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The null hypothesis is that there will be no difference between stress MRI perfusion and cardiac CT with respect to the diagnostic costs for patients with an equivocal stress study for CAD.
Time Frame: end of study
|
compare the cost-effectiveness of MRI with CT for this patient population.
|
end of study
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Arlene Sirajuddin, M.D., National Heart, Lung, and Blood Institute (NHLBI)
Publications and helpful links
General Publications
- Hendel RC, Wackers FJ, Berman DS, Ficaro E, DePuey EG, Klein L, Cerqueira M; American Society of Nuclear Cardiology. American Society of Nuclear Cardiology consensus statement: Reporting of radionuclide myocardial perfusion imaging studies. J Nucl Cardiol. 2006 Nov;13(6):e152-6. doi: 10.1016/j.nuclcard.2006.08.013. No abstract available.
- Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, Patel MR, Raskin IE, Hendel RC, Bateman TM, Cerqueira MD, Gibbons RJ, Gillam LD, Gillespie JA, Hendel RC, Iskandrian AE, Jerome SD, Krumholz HM, Messer JV, Spertus JA, Stowers SA; American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group; American Society of Nuclear Cardiology; American Heart Association. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol. 2005 Oct 18;46(8):1587-605. doi: 10.1016/j.jacc.2005.08.029. Erratum In: J Am Coll Cardiol. 2005 Dec 6;46(11):2148-50.
- Hendel RC, Patel MR, Kramer CM, Poon M, Hendel RC, Carr JC, Gerstad NA, Gillam LD, Hodgson JM, Kim RJ, Kramer CM, Lesser JR, Martin ET, Messer JV, Redberg RF, Rubin GD, Rumsfeld JS, Taylor AJ, Weigold WG, Woodard PK, Brindis RG, Hendel RC, Douglas PS, Peterson ED, Wolk MJ, Allen JM, Patel MR; American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group; American College of Radiology; Society of Cardiovascular Computed Tomography; Society for Cardiovascular Magnetic Resonance; American Society of Nuclear Cardiology; North American Society for Cardiac Imaging; Society for Cardiovascular Angiography and Interventions; Society of Interventional Radiology. ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol. 2006 Oct 3;48(7):1475-97. doi: 10.1016/j.jacc.2006.07.003. No abstract available.
Helpful Links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 090164
- 09-H-0164
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.