Plasma Volume Determination by 99mTc-labeled Albumin and 125I-labeled Albumin
Comparison of Plasma Volume Determination by 99mTc-labeled Albumin and 125I-labeled Albumin
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
For many years, radioiodinated albumin has been "the golden standard" for measurement of plasma volume. There are a number of clinical situations in which a nuclide with a shorter half-life would be preferred. Furthermore, due to periodic lapses in the availability in the delivery of 125I-labeled albumin, there is a need to evaluate another nuclide as a tracer for plasma volume determination.
99mTc-labeled albumin is easily prepared by a simple and reproducible method with a high labeling efficiency and short half-life.
In this study, we want to compare plasma volume determined by 99mTc-labeled albumin with plasma volume determined by 125I-albumin (golden standard). In both procedures, plasma volume is estimated from multiple postinjection samples for accurate zero-time extrapolation in order to correct for leakage of labeled albumin from the vascular compartment.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Koge, Denmark, DK-4600
- University Hospital Koge, Department of Clinical Physiology and Nuclear Medicine
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- BMI < 27 kg/m2
- Written informed consent
Exclusion Criteria:
- Hypertension (140/90 mmHg)
- Diabetes mellitus
- Any use of medication
- Pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: Non-Randomized
- Interventional Model: Single Group Assignment
- Masking: Single
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Plasma volume determined by 99mTc-labeled albumin and 125I-labeled albumin
Time Frame: January 2011
|
January 2011
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Rates of loss of 99mTc-labeled albumin and 125I-labeled albumin from the circulation
Time Frame: January 2011
|
January 2011
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Steen Levin, MD, DMSc, Zealand University Hospital
- Principal Investigator: Peter K Bonfils, MD, Zealand University Hospital
- Study Director: Knud H Stokholm, MD, Zealand University Hospital
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- SJ-112
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.