The Use of the GlideScope Ranger in Pediatric Critical Care Transport
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Ohio
-
Akron, Ohio, United States, 44308
- Akron Children's Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- age < 18 years
- Presence of respiratory failure requiring tracheal intubation by the Critical Care Transport Team either at the referring institution or during the transport to the receiving institution
- Ability of parent or legal guardian to provide written informed consent
Exclusion Criteria:
- Patients 18+ years of age
- Patient has a functioning tracheostomy
- Patient does not require orotracheal intubation
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Intubation using GlideScope Ranger
The study site has two critical care transport teams per shift and will, at shift change, assign intubation team A to use the GlideScope Ranger for all intubations on that day.
|
Intubation with GlideScope Ranger Video Laryngoscope
|
|
ACTIVE_COMPARATOR: intubation using direct laryngoscopy
The study site has two critical care transport teams per shift and will, at shift change, assign intubation team B. Team B will do intubations using direct laryngoscopy only that day.
|
Intubations will be done with direct laryngoscopy.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percent of Participants With Successful 1st Intubation Attempt
Time Frame: 30 days
|
Percent of participants with successful 1st intubation attempt by group (GVL vs. DL)
|
30 days
|
|
Overall Successful Intubation Rate: GlideScope Video Laryngoscopy (GVL) vs. Direct Laryngoscopy (DL).
Time Frame: 30 days; no long-term outcome measures were included
|
Overall successful intubation rate defined as all successful intubations (by type) divided by all attempts (by type).
|
30 days; no long-term outcome measures were included
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Michael T Bigham, M.D., Akron Children's Hospital
Publications and helpful links
General Publications
- Cooper RM. The GlideScope videolaryngoscope. Anaesthesia. 2005 Oct;60(10):1042. doi: 10.1111/j.1365-2044.2005.04384.x. No abstract available.
- Lim TJ, Lim Y, Liu EH. Evaluation of ease of intubation with the GlideScope or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy. Anaesthesia. 2005 Feb;60(2):180-3. doi: 10.1111/j.1365-2044.2004.04038.x.
- Malik MA, O'Donoghue C, Carney J, Maharaj CH, Harte BH, Laffey JG. Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study. Br J Anaesth. 2009 Jan;102(1):128-34. doi: 10.1093/bja/aen342.
- Rai MR, Dering A, Verghese C. The Glidescope system: a clinical assessment of performance. Anaesthesia. 2005 Jan;60(1):60-4. doi: 10.1111/j.1365-2044.2004.04013.x.
- Kim JT, Na HS, Bae JY, Kim DW, Kim HS, Kim CS, Kim SD. GlideScope video laryngoscope: a randomized clinical trial in 203 paediatric patients. Br J Anaesth. 2008 Oct;101(4):531-4. doi: 10.1093/bja/aen234. Epub 2008 Aug 8.
- Milne AD, Dower AM, Hackmann T. Airway management using the pediatric GlideScope in a child with Goldenhar syndrome and atypical plasma cholinesterase. Paediatr Anaesth. 2007 May;17(5):484-7. doi: 10.1111/j.1460-9592.2006.02149.x.
- Taub PJ, Silver L, Gooden CK. Use of the GlideScope for airway management in patients with craniofacial anomalies. Plast Reconstr Surg. 2008 Apr;121(4):237e-238e. doi: 10.1097/01.prs.0000305397.19883.a7. No abstract available.
- Trevisanuto D, Fornaro E, Verghese C. The GlideScope video laryngoscope: initial experience in five neonates. Can J Anaesth. 2006 Apr;53(4):423-4. doi: 10.1007/BF03022520. No abstract available.
- Nichols, D.G. and M.C. Rogers, Rogers' textbook of pediatric intensive care. 4th ed. 2008, Philadelpia: Lippincott Williams & Wilkins. No PMID Available.
- 04/14/2009 [cited 2009 June]; Available from: http://www.aap.org/sections/transmed/DatabaseTM.pdf
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 090903
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.