Covered Metallic Stents for First-Line Treatment of Benign Bile Duct Strictures
Use of Fully-covered, Self-expandable Metallic Stents for First-line Treatment of Benign Bile Duct Strictures
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Wolverhampton, United Kingdom
- Royal Wolverhampton Nhs Trust
-
-
-
-
Illinois
-
Chicago, Illinois, United States
- University of Chicago
-
-
Indiana
-
Indianapolis, Indiana, United States, 46202
- Indiana University
-
-
Michigan
-
Ann Arbor, Michigan, United States
- University of Michigan
-
-
Missouri
-
Saint Louis, Missouri, United States, 63108
- Washington University in St. Louis
-
-
Pennsylvania
-
Pittsburgh, Pennsylvania, United States
- University of Pittsburgh Medical Center
-
-
South Carolina
-
Charleston, South Carolina, United States, 29425
- Medical University of South Carolina
-
-
Texas
-
Dallas, Texas, United States
- Digestive Health Associates of Texas
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Bismuth Type I benign bile duct stricture
- Objective signs/symptoms related to the stricture
Exclusion Criteria:
- Suspected malignant etiology for the stricture
- Prior endotherapy within one year of presentation,except in the following two scenarios: 1) Early (< 30 days) stent placement following liver transplant; 2) in patients with chronic pancreatitis, single plastic stent placed during presenting ERCP while evaluating for malignancy
- Bismuth Type II-IV stricture
- Proximal common hepatic duct diameter < 6 mm
- Intact gallbladder, except in cases where a stent can be deployed > 1cm below the cystic duct insertion
- Age < 18 years, pregnancy, incarceration, inability to provide informed consent
- Karnofsky score ≤ 40
- Inability to pass a guidewire proximal to the stricture
- Stricture > 8cm in length
- Life expectancy < 1 year
- Concomitant nonanastomotic biliary strictures or biliary casts
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Fully Covered Metallic Stent
Among patients randomized to the covered, self-expandable metallic stent (cSEMS) group, the endoscopist will deploy a cSEMS of sufficient length to traverse the papilla.
Dilation will not be performed unless the cSEMS deployment catheter cannot be advanced over a guidewire beyond the stricture.
A biliary sphincterotomy may be performed at the discretion of the treating endoscopist.
|
Covered Wallflex Biliary (TM)
|
|
ACTIVE_COMPARATOR: Plastic Stent
Patients randomized to the plastic stent (PS) group will be treated using a standard algorithm.
Specifically, the stricture will be dilated using a passage dilator and/or dilation balloon catheter, and multiple (as many as technically feasible) PS will be deployed depending on the baseline characteristics of the stricture as well as the diameter of the proximal and distal bile duct (standard of care).
The endoscopist will sequentially dilate and upsize the cumulative stent diameter on ensuing endoscopic retrograde cholangiopancreatography (ERCP), until the stricture has been obliterated using clinical and fluoroscopic criteria (details below).
|
Patients randomized to the PS group will be treated using a standard algorithm.
Specifically, the stricture will be dilated using a passage dilator and/or dilation balloon catheter, and one or two PS will be deployed depending on the baseline characteristics of the stricture as well as the diameter of the proximal and distal bile duct (standard of care).
The endoscopist will sequentially dilate and upsize the cumulative stent diameter on ensuing ERCPs, until the stricture has been obliterated using clinical and fluoroscopic criteria.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Early Clinical Success
Time Frame: Post-stent removal (up to one year after enrollment)
|
Early clinical success will be defined as fluoroscopic resolution at the time all stent(s) are removed.
If there is a persistent stricture after 12 months of stent therapy in either group, the patient will be classified as a clinical failure.
We will compare early clinical success rates in each group.
|
Post-stent removal (up to one year after enrollment)
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- G100118
- R21DK090708 (NIH)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.