A Critical Appraisal of the Role of Near Infrared Spectroscopy (NIRS) in the Pediatric Intensive Care Unit (PICU)
Is There a Canary in the PICU? A Critical Appraisal of the Role of Near Infrared Spectroscopy (NIRS) in the Pediatric Intensive Care Unit (PICU)
Study Overview
Status
Status
Conditions
Conditions
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Ohio
-
Akron, Ohio, United States, 44308
- Akron Children's Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- neonates to 16 year olds
- requiring stay in the PICU greater than 24 hours
Exclusion Criteria:
- anticipated PICU stay less than 24 hours
- children with ALLOW NATURAL DEATH orders
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
Cardiac patients
Postoperative congenital heart disease patients requiring stay in the PICU
|
|
non-cardiac patients
non-cardiac patients requiring stay in the PICU
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparison of data obtained using Near Infrared Spectroscopy (NIRS) versus traditional Pediatric Intensive Care Unit (PICU) clinical parameters
Time Frame: 48 hours
|
Upon arrival to PICU, 1 lead will be place on the forehead to monitor cerebral regional saturation (CrSO2)and 1 lead will be placed on the flank to measure somatic regional saturation (SrSO2).
|
48 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Michael L Forbes, MD, FAAP, Akron Children's Hospital
Publications and helpful links
General Publications
- Lima A, Bakker J. Noninvasive monitoring of peripheral perfusion. Intensive Care Med. 2005 Oct;31(10):1316-26. doi: 10.1007/s00134-005-2790-2. Epub 2005 Sep 17.
- Kelleher JF. Pulse oximetry. J Clin Monit. 1989 Jan;5(1):37-62. doi: 10.1007/BF01618369.
- Webster JG 1997 Design of Pulse Oximeters (Bristol: Institute of Physics Publishing)
- Lima AP, Beelen P, Bakker J. Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. Crit Care Med. 2002 Jun;30(6):1210-3. doi: 10.1097/00003246-200206000-00006.
- Armonda RA, McGee B, Veznadaraglu E, Rosenwasser RH. Near-infrared spectroscopy (NIRS) measurements of cerebral oximetry in the neurovascular ICU. Crit Care Med 1999; 27:173
- Kohn, Linda T, Corrigan, J, Donaldson, Molla S. To err is human: building a safer health system. Institute of Medicine (U.S.). Committee on Quality of Health Care in America. Vol. 627, Nov.1999
- Standards of evidence for the safety and effectiveness of critical care monitoring devices and related interventions. Coalition for Critical Care Excellence: Consensus Conference on Physiologic Monitoring Devices. Crit Care Med. 1995 Oct;23(10):1756-63. doi: 10.1097/00003246-199510000-00022.
- Prough DS, Pollard V. Cerebral near-infrared spectroscopy: ready for prime time? Crit Care Med. 1995 Oct;23(10):1624-6. doi: 10.1097/00003246-199510000-00004. No abstract available.
- Feldman MD, Petersen AJ, Karliner LS, Tice JA. Who is responsible for evaluating the safety and effectiveness of medical devices? The role of independent technology assessment. J Gen Intern Med. 2008 Jan;23 Suppl 1(Suppl 1):57-63. doi: 10.1007/s11606-007-0275-4.
- Mullner M, Sterz F, Binder M, Hirschl MM, Janata K, Laggner AN. Near infrared spectroscopy during and after cardiac arrest--preliminary results. Clin Intensive Care. 1995;6(3):107-11.
- Schwarz G, Litscher G, Kleinert R, Jobstmann R. Cerebral oximetry in dead subjects. J Neurosurg Anesthesiol. 1996 Jul;8(3):189-93. doi: 10.1097/00008506-199607000-00001.
- Tobias JD. Cerebral oximetry monitoring with near infrared spectroscopy detects alterations in oxygenation before pulse oximetry. J Intensive Care Med. 2008 Nov-Dec;23(6):384-8. doi: 10.1177/0885066608324380.
- Tobias JD. Cerebral oximetry monitoring provides early warning of hypercyanotic spells in an infant with tetralogy of Fallot. J Intensive Care Med. 2007 Mar-Apr;22(2):118-20. doi: 10.1177/0885066606297966.
- Lee TS, Hines GL, Feuerman M. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy. Ann Vasc Surg. 2008 Jan;22(1):58-62. doi: 10.1016/j.avsg.2007.07.022. Epub 2007 Nov 26.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 100603
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.