Comparative Study of Surgical Completeness After Robotic Thyroidectomy Versus Conventional Open Thyroidectomy
Study Overview
Status
Status
Conditions
Conditions
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of, 120-752
- Severance Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- age ≥ 20years
- papillary thyroid carcinoma patients who underwent conventional open or robotic bilateral total thyroidectomy at YUHS(Yonsei University Health System)
- patient who underwent postoperative low doe (30mCI) RAI ablation therapy at YUHS
Exclusion Criteria:
- pregnant, lactating women
- patient who underwent postoperative low dose RAI at another hospital
- patient with distant metastasis
- patient who underwent combined operation with bilateral total thyroidectomy (ex) Modified radical neck dissection, selective neck node excision d/t lateral neck node metastasis
- patient who underwent High dose (more than 30 mCI) RAI therapy
Study Plan
How is the study designed?
Design Details
- Observational Models: Case-Only
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
Group 1
Group 1 : conventional open thyroidectomy group (papillary thyroid carcinoma patient who underwent conventional open bilateral total thyroidectomy procedure and postoperative low dose RAI therapy)
|
|
Group 2
Group 2 : robotic thyroidectomy group (papillary thyroid carcinoma patient who underwent robotic bilateral total thyroidectomy procedure and postoperative low dose RAI therapy)
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
surgical completeness of conventional open thyroidectomy and robotic thyroidectomy
Time Frame: 12 months after low dose RAI albation therapy
|
check remnant thyroid uptake at Diagnostic RAI scan and stimulated serum thyroglobulin level
|
12 months after low dose RAI albation therapy
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Kang SW, Lee SC, Lee SH, Lee KY, Jeong JJ, Lee YS, Nam KH, Chang HS, Chung WY, Park CS. Robotic thyroid surgery using a gasless, transaxillary approach and the da Vinci S system: the operative outcomes of 338 consecutive patients. Surgery. 2009 Dec;146(6):1048-55. doi: 10.1016/j.surg.2009.09.007. Epub 2009 Oct 30.
- Kang SW, Jeong JJ, Nam KH, Chang HS, Chung WY, Park CS. Robot-assisted endoscopic thyroidectomy for thyroid malignancies using a gasless transaxillary approach. J Am Coll Surg. 2009 Aug;209(2):e1-7. doi: 10.1016/j.jamcollsurg.2009.05.003. Epub 2009 Jun 12. No abstract available.
- Kang SW, Jeong JJ, Yun JS, Sung TY, Lee SC, Lee YS, Nam KH, Chang HS, Chung WY, Park CS. Robot-assisted endoscopic surgery for thyroid cancer: experience with the first 100 patients. Surg Endosc. 2009 Nov;23(11):2399-406. doi: 10.1007/s00464-009-0366-x. Epub 2009 Mar 5.
- Lee J, Nah KY, Kim RM, Ahn YH, Soh EY, Chung WY. Differences in postoperative outcomes, function, and cosmesis: open versus robotic thyroidectomy. Surg Endosc. 2010 Dec;24(12):3186-94. doi: 10.1007/s00464-010-1113-z. Epub 2010 May 19.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 4-2011-0082
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.