Safety and Efficacy Study of MGuard Stent After a Heart Attack (MASTER)
MASTER: MGUARD for Acute ST Elevation Reperfusion
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Białystok, Poland
- Klinika Kardiologii Inwazyjnej Uniwersytetu Medycznego w Białymstoku
-
Krakow, Poland
- Gilghsin: John Paul II Hospital
-
Krakow, Poland
- Szpital Uniwersytecki w Krakowie
-
Nowy Targ, Poland
- Oddział Kardiologii Inwazyjnej
-
Oświęcim, Poland
- Centrum Kardiologii Inwazyjnej GVM Carint
-
Warsaw, Poland
- Centralny Szpital Kliniczny MSWiA w Warszawie
-
-
-
-
-
Johannesburg, South Africa
- Milpark Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria
- 18 years of age
- ST-segment elevation (more than 2mm in more than contiguous leads)
- MI with symptom onset less than 12h
- The patient is willing to comply with specified follow-up evaluations
- Signed ICF
- Single de novo lesion in the target (culprit) vessel
- Target lesion maximum length is 33 mm (by visual estimation)
- Reference vessel diameter must be more than 3.0 to less than 4.0 mm by visual estimation
- Randomization should occur as soon as Presence of TIMI 2 or 3 before randomization Exclusion Criteria
- Pregnant or nursing patients
- Left Bundle Branch Block (LBBB), paced rhythm, or other Electrocardiogram (ECG) abnormality
- Impaired renal function
- Prior coronary artery bypass graft surgery
- Bleeding diathesis
- Contraindication to aspirin
- cardiopulmonary resuscitation
- Cardiogenic shock
- chronic warfarin anticoagulation
- LVEF less than 20%
- other medical illness
- participation in another investigational drug or device study that has not reached its primary endpoint
- Left main coronary artery disease with 50% stenosis
- Ostial target lesion
- Failure to visualize vessel anatomy distal to the culprit lesion
- Moderate to heavily calcified target lesion or vessel
- excessive tortuosity
- bifurcation with a side branch more than 2.0 mm in diameter
- A significant (greater than 50%) stenosis proximal or distal to the target lesion is present that cannot be covered by same single stent
- Diffuse disease distal to target lesion with impaired runoff
- Any prior stent proximal to the target lesion, or within 10 mm distal of the target lesion
- PCI of another lesion performed within 6 months before the index procedure
- Target lesion located in a saphenous vein graft
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: MGuard
MGuard stent will be deployed
|
MGuard™ stent comprises a balloon-expandable, thin-strut stainless steel (316L) bare metal stent platform (strut width 100 µm) with mesh sleeve fibers of polyethyleneterephtalate (fiber width of 20 µm) attached to its outer surface.
These fibers act like a net (aperture size 150 x 180 µm) preventing distal embolization of the plaque debris/thrombus placed between the vessel wall and the stent.
|
|
Active Comparator: BMS or DES
A regular bare metal stent or drug-eluting stent will be deployed
|
Control BMS or DES
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
The incidence of complete ST segment resolution (defined as ≥70% ST 1. The incidence of complete ST segment resolution
Time Frame: 60 to 90 minutes after the last angiogram
|
60 to 90 minutes after the last angiogram
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The incidence of Thrombolysis In Myocardial Infarction (TIMI) 3 flow at the end of the procedure.
Time Frame: 60-90 minutes after last angiogram
|
The incidence of TIMI 3 flow at the end of the procedure.
|
60-90 minutes after last angiogram
|
|
Major Adverse Cardiac Events (MACE)at discharge, 30 days, 6 months and 12 months post-procedure
Time Frame: discharge, 30 days, 6 and 12 months post-procedure
|
Major Adverse Cardiac Events (MACE): defined as cardiac death, reinfarction (Q wave and non-Q wave), or repeat ischemia-driven target lesion revascularization (TLR) by percutaneous or surgical methods at hospital discharge, 30 days, 6 months and 1 year post-procedure.
|
discharge, 30 days, 6 and 12 months post-procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Alexandre Abizaid, MD, PhD, Inst Dante Pazzanese of Cardiology, Brazil
- Principal Investigator: Dariusz Dudek, MD, PhD, Cardiac Catheterization Laboratories, Krakow, Poland
- Principal Investigator: Sigmund Silber, MD, PhD, Heart Center at the Isar Academic Teaching Site of the University of Munich
- Study Chair: Gregg Stone, MD, Columbia University Medical Center The Cardiovascular Research Foundation
Publications and helpful links
General Publications
- Dudek D, Dziewierz A, Brener SJ, Abizaid A, Merkely B, Costa RA, Bar E, Rakowski T, Kornowski R, Dressler O, Abizaid A, Silber S, Stone GW. Mesh-covered embolic protection stent implantation in ST-segment-elevation myocardial infarction: final 1-year clinical and angiographic results from the MGUARD for acute ST elevation reperfusion trial. Circ Cardiovasc Interv. 2015 Feb;8(2):e001484. doi: 10.1161/CIRCINTERVENTIONS.114.001484.
- Dudek D, Brener SJ, Rakowski T, Dziewierz A, Abizaid A, Silber S, Yaacoby E, Dizon JM, Costa RA, Maehara A, Dressler O, Stone GW. Efficacy of an Embolic Protection Stent as a Function of Delay to Reperfusion in ST-Segment Elevation Myocardial Infarction (from the MASTER Trial). Am J Cardiol. 2014 Nov 15;114(10):1485-9. doi: 10.1016/j.amjcard.2014.08.007. Epub 2014 Aug 27.
- Stone GW, Abizaid A, Silber S, Dizon JM, Merkely B, Costa RA, Kornowski R, Abizaid A, Wojdyla R, Maehara A, Dressler O, Brener SJ, Bar E, Dudek D. Prospective, Randomized, Multicenter Evaluation of a Polyethylene Terephthalate Micronet Mesh-Covered Stent (MGuard) in ST-Segment Elevation Myocardial Infarction: The MASTER Trial. J Am Coll Cardiol. 2012 Nov 6;60(19):1975-84. doi: 10.1016/j.jacc.2012.09.004.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IMD-07
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.