Effect of Wide Pulse Pressure on the Predictability of Stroke Volume Variation for Fluid Responsiveness in Patients Undergoing Off-pump Coronary Artery Bypass Graft
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of, 120-752
- Department of Anesthesiology and Pain Medicine and Anesthesia and Pain Research Institute, Yonsei University College of Medicine
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 1. Age ≥ 20
- 2. elective off-pump coronary artery bypass graft
Exclusion Criteria:
- 1. arrhythmia
- 2.EF <40%
- 3.valvular heart dz
- 4.pul HTN
- 5.PAOD
- 6.lung dz
- 7.NYHA IV
- 8.ESRD
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Normal pulse pressure
pulse pressure <60mmHg
|
HES 130/0.4
(VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading during 15 minutes after induction of anesthesia
|
|
Other: Wide pulse pressure
pulse pressure ≥60mmHg
|
HES 130/0.4
(VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading during 15 minutes after induction of anesthesia
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
The predictability of stroke volume variation for fluid responsiveness in patients with wide pulse pressure
Time Frame: 30 min
|
30 min
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Cut off value of stroke volume variation for predicting fluid responsiveness in patients with wide pulse pressure
Time Frame: 30 min
|
30 min
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB 1-2010-0039
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Stroke Volume Variation
-
NCT06733389Not yet recruitingStroke Volume Variation | Pleth Variability Index | Pulse Pressure Variation
-
NCT04177225CompletedDiastolic Dysfunction | Stroke Volume Variation
-
NCT06734650Not yet recruitingStroke Volume Variation | Pulse Pressure Variation | Deep Learning Model | Arterial Wave Reflections | Peripheral Vein
-
NCT04388995UnknownFluid Therapy | Fluid Responsiveness | Stroke Volume Variation | Pulse Pressure Variation
-
NCT03215329UnknownStroke Volume Variation | Arterial Pressure
-
NCT03699917CompletedPancreaticoduodenectomy | Stroke Volume Variation
-
NCT01412970WithdrawnComparison of Availability for Prediction of Volume Responsiveness | Comparison of Limits of Agreement for Invasive and Non-invasive Measurement of Stroke Volume Variation
-
NCT06215157Not yet recruitingFluid Responsiveness | Stroke Volume Variation | SVV-FloTrac | Thoracic Electrical Bioimpedance
-
NCT06143111Not yet recruitingFluid Responsiveness | Stroke Volume Variation | SVV-FloTrac | Thoracic Electrical Bioimpedance
Clinical Trials on HES 130/0.4 (VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading
-
NCT02459470Completed
-
NCT02122367UnknownThyroidectomy | Fluid Responsiveness
-
NCT01041742Completed
-
NCT02393196UnknownHypotension | Anesthesia; Adverse Effect, Spinal and Epidural
-
NCT01670604UnknownUrologic Surgical Procedures