AIR OPTIX® COLORS Registration Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Be of legal age of consent and sign Informed Consent document. If under legal age of consent, legally authorized representative must sign Informed Consent document and subject must sign Assent document.
- Normal eyes and not using any ocular medications.
- Willing to wear visitint or gray-colored spherical contact lenses in both eyes within available power ranges.
- Manifest cylinder less than or equal to 0.75 diopter.
- Best spectacle corrected visual acuity greater than or equal to 20/25.
- Have current prescription glasses.
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Anterior segment infection, inflammation, or abnormality.
- Any active anterior segment ocular or systemic disease that would contraindicate contact lens wear.
- Use of ocular or systemic medications for which contact lens wear could be contraindicated as determined by the investigator.
- History of refractive surgery or irregular cornea.
- History of pathologically dry eye.
- Corneal vascularization greater than 1 millimeter of penetration.
- History of herpetic keratitis.
- Eye injury within 12 weeks immediately prior to enrollment in this trial.
- Currently enrolled in any clinical trial or participation in any clinical trial within the previous 30 days.
- Other protocol-defined exclusion criteria may apply.
Study Plan
How is the study designed?
Design Details
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: AIR OPTIX® COLORS
Lotrafilcon B contact lenses with color worn in both eyes on a daily wear, monthly replacement basis for 3 months
|
Silicone hydrogel contact lens with color
Other Names:
|
|
Active Comparator: AIR OPTIX® AQUA
Lotrafilcon B contact lenses worn in both eyes on a daily wear, monthly replacement basis for 3 months
|
Silicone hydrogel contact lens
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Contact Lens-Corrected Distance Monocular Snellen Visual Acuity (VA) (20/30 or Better)
Time Frame: Up to Month 3
|
Visual acuity, as assessed for each eye individually.
Participant read a distance Snellen chart while wearing study lenses.
The percentage of eyes with VA recorded as 20/30 or better is reported.
Both eyes contributed to the percentage.
|
Up to Month 3
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Subjective Rating of Overall Comfort
Time Frame: Up to Month 3
|
Overall comfort, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent.
The participant rated both eyes together by providing one single rating.
|
Up to Month 3
|
|
Subjective Rating of Overall Vision
Time Frame: Up to Month 3
|
Overall vision, as rated by the participant on a 10-point scale, with 1 being poor and 10 being excellent.
The participant rated both eyes together by providing one single rating.
|
Up to Month 3
|
|
Subjective Rating of Overall Handling
Time Frame: Up to Month 3
|
Overall handling, as rated by the participant on a 10-point scale, with 1 being difficult and 10 being easy.
The participant rated both eyes together by providing one single rating.
|
Up to Month 3
|
|
Lens Fit (Optimal, Acceptably Loose, Acceptably Tight)
Time Frame: Up to Month 3
|
Lens fit, as assessed by the investigator for each eye individually.
Lens fit was rated on a 5-point scale: 2=unacceptably loose, 1=acceptably loose, 0=optimal, -1=acceptably tight, -2=unacceptably tight.
The combined percentage of lenses assessed as "optimal," "acceptably loose," or "acceptably tight" is reported.
Lenses from both eyes contributed to the percentage.
|
Up to Month 3
|
|
Lens Centration (Centered, Slight Decentration)
Time Frame: Up to Month 3
|
Lens centration, as assessed by the investigator for each eye individually.
Lens centration was rated on a 5-point scale: 0=centered, 1=slight decentration, 2=mild decentration, 3=moderate decentration, 4=severe decentration.
The combined percentage of lenses assessed as "centered" or "slight decentration" is reported.
Lenses from both eyes contributed to the percentage.
|
Up to Month 3
|
|
Dry Areas/Non-Wetting (None, Very Slight)
Time Frame: Up to Month 3
|
Dry areas/non-wetting (i.e., assessment of the disruption of the front surface wettability of the contact lens), as assessed by the investigator for each eye individually.
Dry areas/non-wetting was rated on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe.
The combined percentage of lenses assessed as "none" or "very slight" is reported.
Lenses from both eyes contributed to the percentage.
|
Up to Month 3
|
|
Front Surface Deposits (None, Very Slight)
Time Frame: Up to Month 3
|
Front surface deposits on the contact lens, as assessed by the investigator for each eye individually.
Front surface deposits were rated on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe.
The combined percentage of lenses assessed as "none" or "very slight" is reported.
Lenses from both eyes contributed to the percentage.
|
Up to Month 3
|
|
Back Surface Deposits (None, Very Slight)
Time Frame: Up to Month 3
|
Back surface deposits on the contact lens, as assessed by the investigator for each eye individually.
Back surface deposits were rated on a 5-point scale: 0=none, 1=very slight, 2=slight, 3=moderate, 4=severe.
The combined percentage of lenses assessed as "none" or "very slight" is reported.
Lenses from both eyes contributed to the percentage.
|
Up to Month 3
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Sharon Holden Thomas, OD, Alcon Research
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- P-383-C-003 (C-11-032)
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.