Radiation Exposure During Endoscopic Retrograde Cholangiopancreatography Between Prone and Left Lateral Decubitus
Different Radiation Exposures to Patient and Endoscopists Between Performing ERCP in Patients Lying Prone and Left Lateral Decubitus
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
Bangkok
-
Patumwan, Bangkok, Thailand, 10330
- King Chulalongkorn Memorial Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients with common bile duct (CBD) stone and underwent ERCP
- age over 18 years
- ASA class I-II
Exclusion Criteria:
- Pregnant
- Abnormal coagulation
- ASA class III-IV
- Emergency/urgency conditions
- Unstable vital signs
- Denied to participate the study
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Prone
Patients were in prone position along the ERCP procedure.
|
Fluoroscopy was used during ERCP procedure.
With automatic brightness adjustment, patients with thicker body will get greater radiation dose.
Other Names:
|
|
ACTIVE_COMPARATOR: Left lateral decubitus
Patients were in left lateral decubitus along the ERCP procedure.
|
Fluoroscopy was used during ERCP procedure.
With automatic brightness adjustment, patients with thicker body will get greater radiation dose.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Patients' entrance surface dose
Time Frame: within 12 hours after procedure
|
Transparent ionization chamber was placed at the light beam diaphragm of the x-ray tube to measure the dose in the air and the verification film was placed on the couch at fluoroscopic area to determine exposed area.
Patient's dose-area product will express in cGy.cm2.
|
within 12 hours after procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Endoscopists' radiation dose
Time Frame: Within 12 hours after procedure
|
Thermoluminescent dosimeters (TLD) were placed at left eye, thyroid, left forearm, lower abdomen, and left leg of endoscopists.
The TLDs used in this study was TLD-100 which was lithium fluoride crystal doped with magnesium and titanium (LiF:Mg, Ti).
After procedures all labeled TLDs were read by automatic TLD reader (Harshaw 5500, Thermo Scientific Corp., MA, USA).
|
Within 12 hours after procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Phonthep Angsuwatcharakon, MD, MSc, Chulalongkorn University
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- PA-E-RAD001
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.