Impact of Volume Imaging Using Diagnostic Ultrasound
Impact of Volume Imaging With Ultrasound
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Michigan
-
Ann Arbor, Michigan, United States, 48109
- University of Michigan
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age 18 or older
- Must be scheduled to have a musculoskeletal (bone, ligament, muscle, tendon) ultrasound performed as part of their routine clinical care.
Exclusion Criteria:
- Unable to lie flat on ultrasound table.
- Subjects under 18 years of age
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Volume Imaging scan
New type of ultrasound scan using General Electric US scanner, Model is a GE Logiq E9.
|
Subject will be required to lie flat for no longer than 3 minutes to complete a volume imaging ultrasound scan of the injured area.
Following the volume imaging scan a conventional ultrasound scan will be completed as ordered by their clinician.
Other Names:
The subject will be required to lie flat for approximately 5 to 10 minutes to complete a conventional ultrasound scan to x-ray the muscle and tendon injuries.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy of 3D Ultrasound Scanning Expressed as Percent Correlation Between Images From Conventional Ultrasound and Volume Imaging
Time Frame: Up to 13 minutes
|
Both ultrasound and volume imaging scans were done on the same day.
For all scanned patients, the ultrasound technologist took a volume of images focusing where the patient had symptoms.
The study PI reviewed the images, then went back in to do second scan.
It took 5 to 10 minutes to complete a conventional ultrasound scan and up to 3 minutes to complete a volume imaging ultrasound scan.
|
Up to 13 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Jon Jacobson, M.D., University of Michigan Hospital
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- HUM00030780
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.