Evaluation of Luminal Expansion Following Stenting of Femoro-popliteal Occlusive Disease
C-arm CT Evaluation of Luminal Expansion in Stenting Severe Femoro-popliteal Atherosclerotic Disease: Supera Versus LifeStent
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Nova Scotia
-
Halifax, Nova Scotia, Canada, B3H 2Y9
- Queen Elizabeth Ii Health Sciences Centre
-
-
Quebec
-
Montreal, Quebec, Canada, H2L 4M1
- Centre Hospitalier de l'Université de Montréal
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age ≥ 18 years
- Patient (or legally authorized representative) must give a written informed consent.
- Symptomatic peripheral-artery disease with moderate or severe intermittent claudication and failure of medical treatment (Rutherford stage 2,3) or chronic critical limb ischemia with pain while the patient is at rest (Rutherford stage 4) or chronic critical limb ischemia with ischemic ulcers (Rutherford stage 5, 6) and stenosis of more than 70 percent or occlusion of the ipsilateral superficial femoral artery and/or proximal popliteal artery with a target-lesion length of ≥ 8 and ≤ 20 cm and at least one patent (less than 50 percent stenosed) tibioperoneal runoff vessel (TASC A,B,C lesions)25. Proximal popliteal artery is defined as the popliteal artery above the joint line. The distal portion of the lesion should be located at least 4 cm above the joint line and the distal end of the stent 2 cm above the joint line.
- ABI ≤ 0.9 at rest. Toe-Brachial Index (TBI) may be used if ABI is inadequate.
- Lesion with a calcification percentage of at least 25% based on CTA evaluation (within 6 months of patient enrolment)
Exclusion Criteria:
- Acute critical limb ischemia
- Untreated inflow disease of the ipsilateral pelvic arteries (more than 50 percent stenosis or occlusion).
- Renal failure, creatinine clearance < 50 µmol /l
- Severe allergy to iodine contrast
- Patients with uncorrected bleeding disorders or patients who cannot receive anticoagulation or antiplatelet aggregation therapy
- Lesions < 8 and > 20 cm in length
- Calcification volume of less than 25%
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: SINGLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Supera stent
The Supera stent is a novel interwoven nitinol stent design with high flexibility and radial strength.
The radial force of the Supera stent is 4 times higher than comparable nitinol stent.
|
Angioplasty and stenting will performed according to the guidelines of the Society of Interventional Radiology and the instruction for use for each stent.
Patients will be allocated to Supera stent versus LifeStent based on block randomization (block size 4 patients).
|
|
ACTIVE_COMPARATOR: LifeStent
LifeStent is likely the best reference nitinol stent for comparison because a low restenosis rate has been reported at 1 year with low target revascularization.
|
Angioplasty and stenting will performed according to the guidelines of the Society of Interventional Radiology and the instruction for use for each stent.
Patients will be allocated to Supera stent versus LifeStent based on block randomization (block size 4 patients).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Stent expansion
Time Frame: At the completion of the intervention
|
Difference in minimal lumen diameter (MLD), minimal lumen area (MLA) and incomplete stent expansion as defined by C-arm CT between both groups
|
At the completion of the intervention
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Stent patency
Time Frame: 1 year
|
Correlate stent opening with stent patency as documented by Doppler ultrasound at one year post implantation
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Gilles Soulez, MD, MSc, Centre Hospitalier de l'Université de Montréal
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- CE 12.048
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.