Value of Pulse Pressure Variations and Corrected Flow Time in Esophageal Doppler as a Predictor of Fluid Responsiveness in Prone Position During Spinal Surgery
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of, 120-752
- Department of Anesthesiology and Pain Medicine and Anesthesia
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- patients undergoing elective spine surgery
- age : > 20 and < 70, 3. Patients expecting intraoperative blood loss more than 10% of estimated blood volume
Exclusion Criteria:
- arrhythmias
- BMI > 30 kg/m2
- valvular heart disease
- left ventricular ejection fraction < 50%
- history of lung disease
- pregnancy
- foreigner
- contraindications to esophageal doppler monitoring probe insertion (i.e. oesophageal stent, carcinoma of the oesophagus or pharynx, previous oesophageal surgery, oesophageal stricture, oesophageal varices, pharyngeal pouch, intra-aortic balloon pump, coarctation of the aorta, and severe coagulopathy)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: corrected flow time
|
1.Esophageal doppler monitor (CARDIO Q®, DELTEX MEDICAL.
Brighton, U. K.)-inserted into the esophagus and positioned approximately 35-40 cm from the teeth.
The position of OED prove was confirmed by continuously measuring blood flow velocity in the descending thoracic aorta and focused to find the optimum peak velocity and waveform signal.
Other Names:
2.philips Intelivue MP70 monitors (Intellivue MP70, philips medical Systems, Suresnes, France) -a radial arterial cannula was inserted and arterial pressure waveforms were monitored through Philips Intelivue MP70 monitors.
In the monitor, PPVauto was displayed in real-time.
It based on automatic detection algorithms, kernel smoothing, and rank-order filters.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
PPV(Pulse pressure variation)
Time Frame: 15 minutes after induction of anaesthesia at the supine position
|
15 minutes after induction of anaesthesia at the supine position
|
|
FTc(corrected flow time)
Time Frame: 15 minutes after induction of anaesthesia at the supine position
|
15 minutes after induction of anaesthesia at the supine position
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 1-2010-0046
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.