Intraocular Lens-shell Technique in Phacoemulsification
Intraocular Lens-Shell Technique: An Adjustment of Surgical Procedure Makes Differences in Treating Dense Nucleus Cataract
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510060
- Zhongshan Ophthalmic Center,Sun Yat-Sen University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Aged 50 years or above
- Dense cataract cases were defined as eyes in which the nuclear color was graded IV or V according to the Lens Opacities Classification System III (LOCS III). Special attention was paid in selecting cases without apparent posterior cortical layer.
- No central corneal opacification
- Pupil diameter >= 7 mm after full pharmacological dilation in preoperative assessment
- A preoperative central endothelial cell count of >= 1500 cells/mm2.
Exclusion Criteria:
- Participants with previous intraocular surgery
- Abnormal lens zonules
- Glaucoma
- High myopia (>-6.0 Diopters)
- Pseudoexfoliation
- Uveitis
- Diabetes mellitus
- Those who were not able to come for follow-up visits.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: IOL-shell technique
In this group, before the emulsification of the last nuclear fragment, cohesive viscoelastic material was injected below the nuclear fragment and a foldable IOL was implanted into the well inflated capsular bag posterior to the nuclear fragment.
The remaining last piece of nuclear fragment was then emulsified and removed within the capsular bag.
|
Phacoemulsification was performed with the same device and handpieces, using the same phaco chop technique as in the conventional procedure group.
What was different was that before the emulsification of the last nuclear fragment, cohesive viscoelastic material was injected below the nuclear fragment and a foldable IOL was implanted into the well inflated capsular bag posterior to the nuclear fragment.
The remaining last piece of nuclear fragment was then emulsified and removed within the capsular bag.
|
|
Active Comparator: Conventional procedure
In this group, a Sensar IOL (AMO Laboratories) was implanted in the capsular bag with the injector system after the lens material was completely removed.
The nuclear fragmentation was performed using the Phaco-chop technique, which was then followed by ultrasound emulsification of the nuclear fragments piece by piece.
Due to lack of cortical shell within the capsular bag, special care was taken to carry out the emulsification of the last nuclear fragment at a relatively more anterior anatomical position between the iris plan and the anterior chamber.
|
In this procedure, a IOL was not implanted until all the nuclear fragments were removed.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Central corneal endothelial cell loss
Time Frame: one month
|
Central corneal endothelial cell loss was calculated by subtracting postoperative corneal endothelial cell density from the preoperative baseline level.
|
one month
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
central cornea thickness
Time Frame: one month
|
The temporal corneal thickness and central corneal thickness were measured using the manual measurement scale in the scanning pictures of anterior segment optical coherence tomography preoperatively and at each postoperative visit.
|
one month
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
un-corrected visual acuity
Time Frame: one month
|
The un-corrected visual acuity was measured and recorded using an Early Treatment Diabetic Retinopathy Study chart both before operation and at the 1st, 7th and 30th day after operation.
|
one month
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Chair: Yizhi Liu, Ph.D., Zhongshan Ophthalmic Center, Sun Yat-sen University
Publications and helpful links
General Publications
- Shah PA, Yoo S. Innovations in phacoemulsification technology. Curr Opin Ophthalmol. 2007 Feb;18(1):23-6. doi: 10.1097/ICU.0b013e328011f9d0.
- Luo L, Lin H, He M, Congdon N, Yang Y, Liu Y. Clinical evaluation of three incision size-dependent phacoemulsification systems. Am J Ophthalmol. 2012 May;153(5):831-839.e2. doi: 10.1016/j.ajo.2011.10.034. Epub 2012 Feb 4.
- Hwang HS, Kim EC, Kim MS. Drill-and-crack technique for nuclear disassembly of hard nucleus. J Cataract Refract Surg. 2010 Oct;36(10):1627-30. doi: 10.1016/j.jcrs.2010.08.003.
- Luo L, Lin H, Chen W, Qu B, Zhang X, Lin Z, Chen J, Liu Y. Intraocular lens-shell technique: adjustment of the surgical procedure leads to greater safety when treating dense nuclear cataracts. PLoS One. 2014 Nov 17;9(11):e112663. doi: 10.1371/journal.pone.0112663. eCollection 2014.
Helpful Links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CCPMOH2010-China5
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.