Evaluation of a Novel Electronic Urine Output Monitor (eUOM)
Urine output and urine drain line pressure were monitored while urine was drained into either:
- Accuryn Urine Output Monitor (Potrero Medical) OR
- Criticore Monitor (Bard Medical)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Georgia
-
Augusta, Georgia, United States, 30909
- Joseph M. Still Burn Center at Doctors Hospital
-
-
Texas
-
Galveston, Texas, United States, 77555
- The University of Texas Medical Branch (UTMBP)
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patient must ≥ 18 years of age
- Patient has a Foley catheter and urine collection system is in place per standard clinical decision
- Estimated length of placement of the Foley is 48 hours minimum
- Burn injury ≥ 20% and ≤ 80% total body surface area (TBSA)
- Subject or subject's legally authorized representative is able to give informed consent before entering the study
Exclusion Criteria:
- Currently pregnant or breastfeeding
- Clinical signs or symptoms of a urinary tract infection (UTI)
- Clinical signs or symptoms of a vaginal infection
- Currently has bladder or urethral trauma
- Use of investigational drug/device therapy within the past 4 weeks
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Test- Accuryn Urine Output Monitor
Accuryn Anti-airlock Drainage System was attached to the Foley catheter and urine output / drainage line pressure was monitored.
|
Accuryn is a novel electronic urine output monitor
|
|
Control- Critcore Urine Output Monitor
A commercially available urine output monitor (Criticore, Bard Medical) was attached to the Foley catheter and urine output / drainage line pressure was monitored.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Urine Output of SOC Device Versus Accuryn
Time Frame: 2 - 5 days
|
Urine output as recorded by the SOC when connected to a standard Foley catheter and standard urinary drainage tube will be compared to urine output recorded by Accuryn and the SOC when connected to a standard Foley catheter and the Accuryn Drainage Tube.
|
2 - 5 days
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: George Kramer, UTMB
- Principal Investigator: Bruce Friedman, Joseph M. Stills Burn Center
Publications and helpful links
Helpful Links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- PM-JMSRF2014-BCF01
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.