Tracheal Intubation With Collar Immobilisation : a Comparison of Glidescope and Fastrach
A Comparison of Glidescope and ILMA in Simulated Sercial Spine Injury
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
inclusion criteria: ASA I-II , 18-60 years of age undergoing elective surgery requiring intubation exclusion criteria:
- pregnancy reflux nonfasted head and neck tumors recent flue in 2 weeks
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Kocaeli, Turkey, 41900
- Kocaeli University School of Medicine
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 18-65 years of age
- ASA I-II
- requiring intubation
- BMI<35
Exclusion Criteria:
- less than 18 or higher than 65
- ASA III-IV
- BMI> 35
- PREGNANT
- head and neck tumors
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Glidescope videolaryngoscope
cervical collar was applied to 47 patients then facemask ventilations were recoded intubated with Glidescope and insertion time: handling of the device till the good glottic visualisation intubation time: handling of the device till the capnography appears mucosal damage: bloodstain on the device after removal heart rate preinduction heart rate postinduction heart rate postinsertion heart rate postintubation mean arterial pressure preinduction mean arterial pressure postinduction mean arterial pressure postinsertion mean arterial pressure postintubation wrere recorded.
postoperative minor complications were recorded.
|
videolaryngoscope
|
|
Active Comparator: Intubating laryngeal mask airway
cervical collar was applied to 47 patients then facemask ventilations through the collar were recorded and intubated with ILMA insertion time: handling of the device till the good glottic visualisation appears intubation time: handling of the device till the capnography appears mucosal damage: bloodstain on the device heart rate preinduction heart rate postinduction heart rate posinsertion heart rate postintubation mean arterial pressure preinduction mean arterial pressure postinduction mean arterial pressure postinsertion mean arterial pressure postintubation
|
handling of the device till the optimal ventilation achieved
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
intubation times
Time Frame: From handling of the device till intıbation
|
From handling of the device till intıbation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Heart rate
Time Frame: From Preoperative heart rate till 15 minutes After intubation
|
From Preoperative heart rate till 15 minutes After intubation
|
|
Mean arterial pressure
Time Frame: From preinduction till 15 minutes after intubation
|
From preinduction till 15 minutes after intubation
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
minor complications
Time Frame: From the end of surgery till 2 hours postoperatively
|
From the end of surgery till 2 hours postoperatively
|
|
Mucosal damage
Time Frame: Bloodstain on the device after removal
|
Bloodstain on the device after removal
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Zehra I ARSLAN, Specialist, Anesthesiology and Reanimation
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- KOÜ KAEK 2013/33
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.