Sensor Off Study Using a Nellcor USB Pulse Oximetry Monitor Interface Cable
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Colorado
-
Boulder, Colorado, United States, 80301
- Boulder Clinical Laboratory
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Male or female subjects 18 or older (inclusive)
- Subject is able to participate for the duration of the study
- Subject is willing to sign an informed consent
Exclusion Criteria:
- Previous injury or trauma to fingers or hands that may change blood flow or vascular supply and affect our ability to test sensors
- Physiologic abnormalities that prevent proper application of pulse oximetry sensor
- Severe contact allergies that cause a reaction to standard adhesive materials such as those found in medical sensors and electrodes
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Nellcor USB Pulse Oximeter Monitor Interface Cable Sensor Test
|
Volunteers are subjected to certain simulated, sensor removal conditions known to represent challenges to the sensor-off feature.
Such conditions include exposing the sensor to an ambient light source, sensor slipping off the finger with the light emitter and detector facing each other or a sensor slipping off under a blanket.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Report the Time Until the Device Posts "Sensor Off" After the Sensor is Removed
Time Frame: 1 minute per event, multiple events per subject. Total duration up to 1 hour
|
A series of sensor-off events were collected from subjects in the study using marketed, off-the-shelf sensors.
Each event was marked as pass if event duration (Timeend - Timestart) was less than or equal to 60 seconds; otherwise, the event was marked as greater than or equal to 60 seconds.
The acceptance criteria is if 90% of the time the product posts Sensor Off, or any equal or higher priority alarm, within 60 seconds after sensor is removed.
|
1 minute per event, multiple events per subject. Total duration up to 1 hour
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Eric Heyer, MD, Medtronic - MITG
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- COVMOPR0461
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.