Biomechanical Changes After Trabeculectomy (TE-biomech)
Corneal Biomechanical Changes Following Trabeculectomy
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Saxony
-
Dresden, Saxony, Germany, 01307
- Technical University Dresden
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Glaucoma patients in need of further IOP-reduction despite maximally tolerated therapy and assigned for trabeculectomy. Minimum of 18 years.
Exclusion Criteria:
- Corneal pathologies.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Glaucoma, primary
Glaucoma patients undergoing trabeculectomy
|
Standard trabeculectomy with the use of antimetabolites (mitomycin C) for glaucoma patients with insufficient intraocular pressure (IOP) control taking maximally tolerated IOP-reducing medication, visual field progression despite maximally tolerated IOP-reducing medication, adverse events because of maximally tolerated IOP-reducing medication or nono.compliance.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Corneal biomechanical changes following trabeculectomy
Time Frame: 2-3 years
|
Evaluation of biomechanical properties of the cornea before and after trabeculectomy to evaluate whether intraocular pressure is accurately measured after trabeculectomy.
Corneal hysteresis and corneal resistance factor as measured with the Ocular Response Analyzer and the corneal deformation response to an air-puff as measured with an ultra-high-speed Scheimpflug camera are assessed.
|
2-3 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Intraocular pressure after trabeculectomy
Time Frame: 2-3 years
|
Intraocular pressure is measured with 3 different devices (Goldmann applanation tonometry, Ocular Response Analyzer, Corvis st) prior and at least 6 month after trabeculectomy.
|
2-3 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Karin R Pillunat, MD, Technische Universität Dresden
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- EK399122012
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.