Thoracoabdominal Arortic CTA Study
Comparison of High Iodine Concentration Contrast Material (Isovue 370) vs Standard Protocol (Isovue 300) in Thoracoabdominal Aortic Computed Tomographic Angiography (CTA) for Radiation Dose Reduction
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
North Carolina
-
Durham, North Carolina, United States, 27710
- Duke University Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients undergoing thoracoabdominal aortic (TAA) CTA
- Able to provide informed consent
- Body Mass Index (BMI) equal to or less than 30
Exclusion Criteria:
- Creatinine greater than 2.0
- Allergy to contrast media
- Pregnant women
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Isovue 300 75mL
Isovue 300 75mL injected 120 kVp 250 mAs
|
iodine contrast
|
|
Active Comparator: Isovue 370 75mL
Isovue 370 75mL injected 100 kVp 240 mAs
|
iodine contrast
|
|
Active Comparator: Isovue 370 60mL
Isovue 370 60mL injected 100 kVp 240 mAs
|
iodine contrast
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Radiation Dose
Time Frame: 30 minutes
|
30 minutes
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Signal to Noise Ratio
Time Frame: 30 minutes
|
Calculated as the ratio of mean attenuation values divided by the standard deviation of attenuation values gathered using a circular region of interest in the thoracic aorta.
|
30 minutes
|
|
Hounsfield Unit Attenuation Values
Time Frame: 30 minutes
|
Grayscale values on CT scans are given as Hounsfield units.
These Hounsfield units reflect the attenuation of x-ray beams traversing the aortic lumen.
We will use Hounsfield units to assess whether the tool contrast agents achieve similar attenuation characteristics essential for diagnosing aortic abnormalities.
We will use circular regions of interest in the thoracic aorta to extract the Hounsfield unit measurements.
|
30 minutes
|
|
Variation in Contrast for the Entire Vascular System (coV)
Time Frame: 30 minutes
|
The change in contrast was measured at the proximal segment of the aorta and at the Iliac arteries for each subject.
|
30 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Pro00048275
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.