Intraoperative Ocular Pressure in Lumbar Spine Fusion Patients (IOP)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients undergoing elective lumbar spinal fusion surgery; ages 18-80
Exclusion Criteria:
- Less than 18 years of age
- Glaucoma, previous eye surgery, eye injury, or eye trauma, cervical myelopathy, prior cervical spine surgery, current neoplasm, patients who have neck pain with 10 degrees active extension.
Study Plan
How is the study designed?
Design Details
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Head raised 10 degrees
Head raised 10 degrees from neutral position using Gardner Wells tongs
|
Baseline measurement in seated position; anesthetization in the supine position.
Prior to turning into the prone position, another measurement was taken.
Five minutes after turning prone, a third IOP measurement was obtained.
Head was raised to 10 degrees.
After 5 minutes a fourth IOP measurement was performed.
Repeat measurements were taken every 15 minutes until three sequential measurements were within plus or minus 3 mmHg of one another; thereafter, measurements were obtained every hour until end of case.
A final measurement was taken after turning the patient supine and 5 minutes elapsed for equilibration.
|
|
Active Comparator: Head in neutral position
|
Baseline measurement in seated position; anesthetization in the supine position.
Prior to turning into the prone position, another measurement was taken.
Five minutes after turning prone, a third IOP measurement was obtained.
After 5 minutes a fourth IOP measurement was performed.
Repeat measurements were taken every 15 minutes until three sequential measurements were within plus or minus 3 mmHg of one another; thereafter, measurements were obtained every hour until end of case.
A final measurement was taken after turning the patient supine and 5 minutes elapsed for equilibration.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Intraoperative Ocular Pressure in Lumbar Spine Fusion Patients Head Raised 10 Degrees or Kept in Neutral Position
Time Frame: Prone; 5 minutes after head raised to 10 degrees; every 15 minutes; 1 hr until end of surgery
|
The objective is to determine if slight elevation of the head (10 degrees up from neutral) can decrease the IOP compared to remaining in neutral position (standard of care) for the entire surgery.
The mean values for Δ IOP measurements (i.e. two eye average maximum IOP - two eye average baseline IOP obtained at first prone measurement).
|
Prone; 5 minutes after head raised to 10 degrees; every 15 minutes; 1 hr until end of surgery
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change and Correlations in Intraoperative Ocular Pressure in Lumbar Spine Fusion Patients
Time Frame: prone; every 15 minutes; 1 hr until end of surgery
|
The secondary outcome is to evaluate factors (age, gender, duration of procedure, blood loss, intraoperative fluids, blood pressure, and carbon dioxide levels) looking for correlations with intraocular pressure changes.
|
prone; every 15 minutes; 1 hr until end of surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Sanford E Emery, MD, MBA, West Virginia University
Publications and helpful links
General Publications
- Ozcan MS, Praetel C, Bhatti MT, Gravenstein N, Mahla ME, Seubert CN. The effect of body inclination during prone positioning on intraocular pressure in awake volunteers: a comparison of two operating tables. Anesth Analg. 2004 Oct;99(4):1152-1158. doi: 10.1213/01.ANE.0000130851.37039.50.
- Carey TW, Shaw KA, Weber ML, DeVine JG. Effect of the degree of reverse Trendelenburg position on intraocular pressure during prone spine surgery: a randomized controlled trial. Spine J. 2014 Sep 1;14(9):2118-26. doi: 10.1016/j.spinee.2013.12.025. Epub 2014 Jan 20.
- Walick KS, Kragh JE Jr, Ward JA, Crawford JJ. Changes in intraocular pressure due to surgical positioning: studying potential risk for postoperative vision loss. Spine (Phila Pa 1976). 2007 Nov 1;32(23):2591-5. doi: 10.1097/BRS.0b013e318158cc23.
- Emery SE, Daffner SD, France JC, Ellison M, Grose BW, Hobbs GR, Clovis NB. Effect of Head Position on Intraocular Pressure During Lumbar Spine Fusion: A Randomized, Prospective Study. J Bone Joint Surg Am. 2015 Nov 18;97(22):1817-23. doi: 10.2106/JBJS.O.00091.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 1409441146
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.