Ascension® Post- Approval Study; PyroCarbon Metacarpophalangeal Total Joint Prosthesis (MCP)
Post-Approval Study Protocol; Ascension® MCP Finger Implant; PyroCarbon Metacarpophalangeal Total Joint Prosthesis
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Arizona
-
Tucson, Arizona, United States, 85712
- Southwest Shoulder Elbow and Hand Center, P.C.
-
-
Indiana
-
Bloomington, Indiana, United States, 47403
- Bloomington Bone and Joint Clinic
-
Carmel, Indiana, United States, 46032
- Reconstructive Hand Surgeons of Indiana
-
Indianapolis, Indiana, United States, 46260
- The Indiana Hand Center
-
-
Minnesota
-
Rochester, Minnesota, United States, 55905
- Mayo Clinic Rochester
-
-
Oregon
-
Bend, Oregon, United States, 97701
- The Center for Ortho/ Neuro Care & Research
-
-
Texas
-
Houston, Texas, United States, 77004
- ROC Houston, PA
-
Houston, Texas, United States, 77030
- Fondren Orthopedic Group, L.L.P.
-
San Antonio, Texas, United States, 78229
- The Hand Center of San Antonio
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Indications consistent with the FDA approved Indications For Use: Index, long, ring, or small finger metacarpophalangeal (MCP) joints that exhibit symptoms of pain, limited motion, or inadequate bony alignment (i.e., subluxation/dislocation) secondary to articular destruction or degenerative disease related to rheumatoid arthritis, systemic lupus erythematosus, osteoarthritis, or post-traumatic arthritis where soft tissue reconstruction can provide adequate stabilization
- Willing to participate in the study
- Signed an Informed Consent Form
- The means and ability to return for all required study visits
- Are not transient
Exclusion Criteria:
Patients who have any of the following contraindications will be excluded from the study:
- Inadequate bone stock at the implantation site
- Active infection in the MCP joint
- Nonfunctioning and irreparable MCP musculotendinous system
- Physical interference with or by other prostheses during implantation or use
- Procedures requiring modification of the prosthesis
- Skin, bone, circulatory and/or neurological deficiency at the implantation site
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Ascension® MCP Finger Implant
Single arm study, patient treated with Ascension® PyroCarbon MCP implant.
|
Patients who meet inclusion/ exclusion criteria are treated with the Ascension® MCP.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Participants With Revisions
Time Frame: 12 months
|
Count of participants with a revision surgery.
|
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Joint Range of Motion
Time Frame: Preoperatively to 12 months
|
Range of motion measured by clinical assessment for joint extension and joint flexion.
Measurements of extension and flexion made and recorded to the nearest degree using a goniometer with the wrist in the neutral position.
Extension measured with fingers actively extended and flexion measured after the participant made a fist.
|
Preoperatively to 12 months
|
|
Change in Radial-Ulnar Deviation
Time Frame: Preoperatively to 12 months
|
Measurements of ulnar deviation made for each implanted metacarpophalangeal (MCP) joint.
Measurements made to the nearest degree using a goniometer with the participant's wrist in a neutral position and the finger(s) fully extended (e.g., no extension deficit).
Radial deviation or ulnar deviation direction checked.
|
Preoperatively to 12 months
|
|
Change in Tip Pinch
Time Frame: Preoperatively to 12 months
|
Quantitative measurements of opposition tip pinch strength was made for each implanted digit. Measurements made using a pinch meter. For each strength measurement, the participant made 3 attempts with the maximum value recorded. If the participant could not perform the pinch test due to inflammation, excessive pain, or some other reason, DNA (which stands for "Did Not Attempt") was recorded. If the participant performs the pinch test but cannot register significant load, the value zero (0) was recorded. |
Preoperatively to 12 months
|
|
Change in Grip Strength
Time Frame: Preoperatively to 12 months
|
Implanted hand grip strength measured using a grip dynamometer instrument.
|
Preoperatively to 12 months
|
|
Function Visual Analog Scale (VAS)
Time Frame: Preoperatively, 6 weeks, 12 weeks, 6 months, and 12 months
|
VAS Function based on a scale of 0 to 100 as completed by the participant with 0 indicating worse function and 100 indicating normal function
|
Preoperatively, 6 weeks, 12 weeks, 6 months, and 12 months
|
|
Joint Pain Visual Analog Score (VAS)
Time Frame: Preoperatively, 6 Weeks, 12 Weeks, 6 Months, 12 Months
|
VAS Joint Pain based on a scale of 0 to 100 as completed by the participant with 0 indicating no pain and 100 indicating severe pain.
|
Preoperatively, 6 Weeks, 12 Weeks, 6 Months, 12 Months
|
|
Cosmetic Appearance Visual Analog Scale (VAS)
Time Frame: Preoperatively, 6 Weeks, 12 Weeks, 6 Months, and 12 months
|
VAS Cosmetic Appearance based on a scale of 0 to 100 as completed by the participant with 0 indicating worst appearance and 100 indicating normal appearance.
|
Preoperatively, 6 Weeks, 12 Weeks, 6 Months, and 12 months
|
|
Joint Position
Time Frame: Preoperatively, 6 weeks, 12 weeks, 6 months, and 12 months
|
Joint position for the affected finger determined by radiographic evaluation.
Standard anteroposterior (AP), oblique, and lateral radiographs were made at the pre-operative and all post-operative evaluation visits of the hand(s) in which the Ascension MCP device was implanted.
Joint position was classified as reduced, subluxed, dislocated, or (data) missing.
|
Preoperatively, 6 weeks, 12 weeks, 6 months, and 12 months
|
|
Component Migration
Time Frame: 6 Weeks, 12 Weeks, 6 Months, 12 Months
|
Component migration determined by radiographic assessment.
Migration of the device was classified as none, yes, or (data) missing.
|
6 Weeks, 12 Weeks, 6 Months, 12 Months
|
|
Bone Changes by Device
Time Frame: 6 Weeks, 12 Weeks, 6 Months, 12 Months
|
X-rays were examined to determine if the implant components demonstrate stable fixation in the bone.
Bone changes were classified as no changes (i.e., none), any bone changes, or (data) missing.
|
6 Weeks, 12 Weeks, 6 Months, 12 Months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Andrew Tummon, Sponsor- Integra LifeSciences
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CP-MCP-002
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Osteoarthritis
-
NCT07458971Not yet recruitingThumb Osteoarthritis | Trapeziometacarpal Osteoarthritis | Carpometacarpal Osteoarthritis | Thumb Basal Joint Osteoarthritis
-
NCT04405297TerminatedKnee Osteoarthritis | Hip Osteoarthritis | Shoulder Osteoarthritis | Ankle Osteoarthritis | Wrist Osteoarthritis
-
NCT06717529CompletedOsteoarthritis | Osteoarthritis of the Knee | Osteoarthritis of Knee | Osteoarthritis of the Knees | Osteoarthritis (OA) of the Knee | Osteoarthritis Knee | Osteoarthritis in the Knee | Osteoarthritis of Knee Joint
-
NCT05675618RecruitingKnee Osteoarthritis | Hip Osteoarthritis | Shoulder Osteoarthritis
-
NCT07551856Not yet recruitingOsteoarthritis | Knee Osteoarthritis | Osteoarthritis (OA) | Osteo Arthritis | Osteoarthritis in the Knee | Osteoarthritis (Knee) | Osteo Arthritis of the Knee
-
NCT07324746RecruitingOsteoarthritis | Osteoarthritis (OA) | Osteoarthritis (OA) of the Knee | Osteoarthritis (OA) of the Hip
-
NCT05676567Active, not recruitingKnee Osteoarthritis | Hip Osteoarthritis | Shoulder Osteoarthritis
-
NCT03869229UnknownOsteoarthritis | Knee Osteoarthritis | Hip Osteoarthritis | Glenohumeral Osteoarthritis
-
NCT03866330UnknownOsteoarthritis | Knee Osteoarthritis | Hip Osteoarthritis | Glenohumeral Osteoarthritis
-
NCT07212647CompletedKnee Osteoarthritis | Knee Osteoarthritis (Knee OA)
Clinical Trials on Ascension® MCP Finger Implant
-
NCT03737357CompletedPartially Edentulous Patients
-
NCT05369299CompletedImmediate Implantation of Two-piece Zirconia Dental Implants
-
NCT01109303CompletedAnkle Syndesmosis Rupture
-
NCT01931956CompletedMitral Regurgitation | Mitral Valve Insufficiency | Mitral Valve Regurgitation | Mitral Valve Incompetence | Mitral Insufficiency
-
NCT05501002TerminatedPilot Study to Evaluate the CereVasc® EShunt® System in the Treatment of Communicating HydrocephalusHydrocephalus | Hydrocephalus, Communicating
-
NCT05398341Active, not recruitingAnterior Cruciate Ligament Injuries
-
NCT05119842RecruitingParalysis, Unilateral, Vocal Cord
-
NCT05685316Active, not recruitingCartilage or Osteochondral Defects in the Knee
-
NCT03327090CompletedMuscle Power Performance