Visual Acuity After the Combined Binocular Implantation of +2.75 Diopters and +3.25 Diopters Tecnis Multifocal Intraocular Lenses.
Evaluation of the Visual Acuity After the Implantation of a Tecnis +2.75 Diopters Bifocal Intraocular Lens (Tecnis ZKB00) in the Distance Dominant Eye, in Combination With a +3.25 Diopters Tecnis Bifocal Intraocular Lens (Tecnis ZLB00) in the Fellow Eye.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Berlin, Germany, 1335
- Charité - University Medicine Berlin, Department of Ophthalmology
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- clinically significant cataract
- endothelial cell count: patients aged 18-75 years: > 1000 cells/mm2; patients > 75 years: > 750 cells/mm2
- absence of vision-limiting corneal or retinal comorbidities
- capability to understand the informed consent
Exclusion Criteria:
- expected postoperative astigmatism > 0.75 diopters
- irregular astigmatism
- dilated pupil diameter < 3 mm
- corneal and fundus abnormalities that might cause visual impairments
- inability to attend follow-up visits
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Visual acuities in the far, intermediate and near
Time Frame: 1 month
|
Visual acuities are tested under photopic conditions at 5 m, intermediate (80 cm) and patient-preferred near distance (≈ 40 cm).
|
1 month
|
|
Visual acuities in the far, intermediate and near
Time Frame: 3 months
|
Visual acuities are tested under photopic conditions at 5 m, intermediate (80 cm) and patient-preferred near distance (≈ 40 cm).
|
3 months
|
|
Mesopic vision
Time Frame: 1 month
|
Mesopic visual acuities are tested under high-contrast, low-contrast and low-contrast with glare.
|
1 month
|
|
Mesopic vision
Time Frame: 3 months
|
Mesopic visual acuities are tested under high-contrast, low-contrast and low-contrast with glare.
|
3 months
|
|
Scotopic contrast sensitivity
Time Frame: 1 month
|
Scotopic contrast sensitivity are tested at 0.1 cd/m2, 0.032 cd/m2 and 0.1 cd/m2 with glare.
|
1 month
|
|
Scotopic contrast sensitivity
Time Frame: 3 months
|
Scotopic contrast sensitivity are tested at 0.1 cd/m2, 0.032 cd/m2 and 0.1 cd/m2 with glare.
|
3 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Spectacle independence in the far, intermediate and near
Time Frame: 3 months
|
Spectacle independence as stated by the patient.
|
3 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Eckart Bertelmann, MD, Charité - University Medicine Berlin, Department of Ophthalmology
Publications and helpful links
General Publications
- Kim JS, Jung JW, Lee JM, Seo KY, Kim EK, Kim TI. Clinical Outcomes Following Implantation of Diffractive Multifocal Intraocular Lenses With Varying Add Powers. Am J Ophthalmol. 2015 Oct;160(4):702-9.e1. doi: 10.1016/j.ajo.2015.07.021. Epub 2015 Jul 21.
- Kretz FT, Gerl M, Gerl R, Muller M, Auffarth GU; ZKB00 Study Group. Clinical evaluation of a new pupil independent diffractive multifocal intraocular lens with a +2.75 D near addition: a European multicentre study. Br J Ophthalmol. 2015 Dec;99(12):1655-9. doi: 10.1136/bjophthalmol-2015-306811. Epub 2015 May 18.
- Kretz FT, Koss MJ, Auffarth GU; ZLB00 Study Group. Intermediate and near visual acuity of an aspheric, bifocal, diffractive multifocal intraocular lens with +3.25 D near addition. J Refract Surg. 2015 May;31(5):295-9. doi: 10.3928/1081597X-20150423-02.
- Vega F, Alba-Bueno F, Millan MS, Varon C, Gil MA, Buil JA. Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses. Invest Ophthalmol Vis Sci. 2015 Jun;56(6):3967-75. doi: 10.1167/iovs.15-16600. Erratum In: Invest Ophthalmol Vis Sci. 2017 Sep 1;58(11):4694.
- Vega F, Millan MS, Vila-Terricabras N, Alba-Bueno F. Visible Versus Near-Infrared Optical Performance of Diffractive Multifocal Intraocular Lenses. Invest Ophthalmol Vis Sci. 2015 Nov;56(12):7345-51. doi: 10.1167/iovs.15-17664.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- EA1/171/14
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.