Optical System to Continuously Measure Arterial Blood Pressure (BP)
Comparison of an Optical System to Continuously Measure Arterial Blood Pressure Against a Gold-standard Arterial Catheter
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The measurement of blood pressure during anesthesia is commonly performed by the inflation of a brachial cuff providing only intermittent blood pressure measurements. In some case, it is required to add a continuous invasive monitoring of blood pressure, via the insertion of an arterial catheter. Unfortunately, the related morbidity is not negligible. To limit the consequences of such a gesture, some developments have been done in the past to allow for continuous non-invasive measurements of blood pressure during anesthesia. Unfortunately, most of these devices are subject to important limitations and constraints of use.
A new system has been designed by CSEM consisting of an optical system fixed on patient's skin, absolutely non-invasive and easy to use. In order to study the reliability of this device, the investigators plan to compare its blood pressure estimates against gold-standard arterial catheter measurements during induction of general anesthesia on:
- 40 patients wearing the optical system at the chest.
- and 40 patients wearing the optical system at the fingertip
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Lausanne, Switzerland
- CHUV
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- patient requiring the placement of an arterial catheter for general anesthesia
- minimum of 18 years
- written consent
Exclusion Criteria:
- minor patient or incapable of discernment
- patient with AIMD
- thoracic surgery
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: OBPM 2015-MD-0022 - CHEST
Cohort of 30 patients undergoing general anesthesia, monitored by optical signals at the chest
|
At the onset of general anesthesia:
will be recorded. |
|
Experimental: OBPM 2015-MD-0022 - CHEST & FINGER
Cohort of 10 patients undergoing general anesthesia, monitored by optical signals at the chest and at the fingertip
|
At the onset of general anesthesia:
will be recorded. |
|
Experimental: OBPM 2015-MD-0022 - FINGER
Cohort of 30 patients undergoing general anesthesia, monitored by optical signals at the fingertip
|
At the onset of general anesthesia:
will be recorded. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Error (in mmHg) between paired determinations of arterial blood pressure from an optical device against reference measurements from an arterial catheter
Time Frame: 24 months
|
The signals recorded by the optical blood pressure device will be retrospectively analysed (offline analysis) in order to test the hypothesis that blood pressure values as derived by the new device is comparable to blood pressure values as measured by an arterial catheter within the limits of agreement in mmHg stated by ISO 81060-2 2013.
|
24 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Patrick Schoettker, CHUV
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- BLOOD PRESSURE
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.