Important improvements in aortic valve prostheses technology has been made aiming comparable performance of these prosthesis to surgical valve ones.
The experience with the early generation of aortic valve prostheses revealed some important differences regarding the incidence of paravalvular leakage, need for pacemaker or valve thrombosis among them. Currently the new generations of valve prostheses such as Sapien 3 balloon-expandable valve and Lotus, repositionable valve are the most frequently used devices. There are registry data about the clinical performance of these valve types but a randomized comparison is missing.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Symptomatic aortic valve disease in need of valve replacement
- Heart team (including at least a cardiac surgeon and an interventional cardiologist) agrees on the eligibility that trans-femoral TAVI is appropriate.
- Study patient is an adult of legal consent age.
- Study patient has provided written informed consent to participate in the study
Exclusion Criteria:
- Life expectancy < 12 months due to co-morbid conditions.
- Native aortic valve annulus size and morphology not suitable for Lotus or Sapien prosthesis implantation
- Preexisting bioprosthetic valve or ring in aortic valve position.
- Pre-existing pacemaker or ICD/CRT.
- Cardiogenic shock or hemodynamic instability.
- History of active endocarditis
- Contraindications for a trans-femoral access.
- Severe left ventricular dysfunction with LVEF <30%.
- Severe mitral valve insufficiency.
- Echocardiographic evidence of intracardiac mass, thrombus or vegetation.
- Patients actively participating in another drug or device investigational study and have not yet completed the primary endpoint follow-up period.
- Patients suffering from dementia.
- Pregnant or nursing women
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: repositionable valve prosthesis
Lotus
|
repositionable valve prosthesis implanted via trans-femoral and trans-catheter route
Other Names:
|
|
Active Comparator: balloon-expandable valve prosthesis
Sapien
|
balloon-expandable valve prosthesis implanted via trans-femoral and trans-catheter route
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incidence of new permanent pacemaker implantation
Time Frame: 30 days
|
implantation of PM
|
30 days
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
incidence of any prosthesis regurgitation
Time Frame: 30 days
|
prosthesis regurgitation in echocardiography
|
30 days
|
|
Incidence of any conduction abnormalities
Time Frame: 30 days
|
conduction abnormalities on rest ECG
|
30 days
|
|
Device success rate according to VARC-2 definition
Time Frame: 30 days
|
combined endpoint
|
30 days
|
|
Mortality rate
Time Frame: 30 days
|
all-cause death
|
30 days
|
|
Mortality rate
Time Frame: 1 year
|
all-cause death
|
1 year
|
|
Mortality rate
Time Frame: 2 years
|
all-cause death
|
2 years
|
|
incidence of early safety parameters according to VARC-2 definitions
Time Frame: 30 days
|
combined endpoint
|
30 days
|
|
incidence of combined efficacy according to VARC-2 definitions
Time Frame: 1 year
|
combined endpoint
|
1 year
|
|
incidence of combined efficacy according to VARC-2 definitions
Time Frame: 2 years
|
combined endpoint
|
2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Julinda Mehilli, MD, Munich University Clinic, Ludwig-Maximilians University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- GEMucS001-15
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Valve Disease
-
NCT07363473Not yet recruitingAortic Valve Regurgitation | Aortic Insufficiency | Aortic Valve Disease Mixed
-
NCT07524595Not yet recruitingSurgical Valve Replacement | AORTIC VALVE DISEASES | Valve Disease, Aortic | Valve-in-valve Procedures
-
NCT07368322RecruitingSevere Aortic Valve Disease | Small Aortic Annulus | Aortic Valve Replacement (AVR)
-
NCT07197736RecruitingAortic Stenosis | Aortic Regurgitation | Valvular Heart Disease | Valve Disease, Aortic | Tricuspid Regurgitation (TR) | Mitral Regurgitation (MR)
-
NCT07620925RecruitingAortic Stenosis | Calcific Aortic Valve Disease | Chronic Coronary Syndrome | Calcific Aortic Stenosis
-
NCT06387446RecruitingValve Disease, Heart | Valve Heart Disease | Valve Disease, Aortic
-
NCT06455787RecruitingAortic Valve Regurgitation | Aortic Valve Disease Mixed
-
NCT07453849Not yet recruitingAortic Regurgitation | Transcatheter Aortic Valve Replacement
Clinical Trials on repositionable valve prosthesis
-
NCT03674593Active, not recruitingDegenerative Mitral Valve Disease
-
NCT01368666TerminatedAortic Valve Replacement
-
NCT01683474UnknownAortic Valve Stenosis | Aortic Valve Calcification
-
NCT04417829CompletedHypertension | Aortic Stenosis
-
NCT03453567Active, not recruitingAortic Valve Stenosis | Aortic Valve Disease
-
NCT04204915Recruiting
-
NCT03924661Active, not recruiting
-
NCT05847751Active, not recruitingSevere Aortic Valve Stenosis