Effect of Reduced Noise Levels and Cycled Light on Visual and Neural Development in Preterm Infants
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Shanghai
-
Shanghai, Shanghai, China, 201102
- Children's Hospital of Fudan University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- <37 gestational weeks preterm infants and >1250g birth weight
Exclusion Criteria:
- Major congenital anomaly and infection prior to enrolment
- Infants with surgical issues
Study Plan
How is the study designed?
Design Details
- Primary Purpose: SUPPORTIVE_CARE
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: QUADRUPLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
NO_INTERVENTION: Control
No specific noise reduction strategies to restrict noise exposure less than 45 dB combined with either continuous bright light or continuous near darkness or unstructured combination of the two during the hospitalization.
|
|
|
EXPERIMENTAL: Noise reduction and cycled light
Reduced noise exposure (sound levels <45 dB) and cycled light (approximately 12 hours of light on and 12 hours of light off).
|
Reduced noise exposure (sound levels <45 dB) and cycled light (approximately 12 hours of light on and 12 hours of light off).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Flash visual evoked potentials (FVEP) at 4 weeks of age
Time Frame: at 4 weeks of age
|
FVEP is recorded from each eye individually after they fall asleep.
Three silver-sliver chloride electrodes are placed according to 10-20 International system with active electrode at Oz (1-2 cm above inion), reference electrode at Fz and ground electrode at Cz. Scalp-electrode impedance is usually below 5kΩ but always below 10kΩ.
Flash stimulus (2 Hz.) is given by light emitting diode goggles simulator at a distance of 2 cm to one eye at a time.
100 responses are averaged for each eye automatically in the Nicolet Viking Quest visual electrophysiological device at 1s total sweep time.
Band pass filters are set at 0.1-75 Hz.
The reproducibility of the responses is ensured by repeating the test two or more times.
Responses with excessive artifacts are automatically rejected.
The parameters of P1, N1, P2, N2, P3, and N3 of the FVEP are stored and subsequently assessed by ophthalmologist blinded to the infant's clinical course.
|
at 4 weeks of age
|
|
Bayley Scales of Infant Development, Second Edition (BSID-III) at 18 months of age
Time Frame: at 18 months of age
|
Neurodevelopment outcome is measured with the Bayley Scales of Infant Development, Second Edition (BSID-III) at corrected gestational age of 18 month, assessed by the physician from department of child health care who was blinded with respect to the subjects.
Mental and motor scores were calculated by the BSID-III Mental Developmental Index (MDI) and Psychomotor Developmental Index (PDI).
The subject's neurodevelopmental outcome was classified as delayed if either score was less than 70.
|
at 18 months of age
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time to establish full enteral feeding
Time Frame: birth till discharge from hospital (up to 3 months)
|
up to 3 months
|
birth till discharge from hospital (up to 3 months)
|
|
Weight at discharge
Time Frame: birth till discharge from hospital (up to 3 months)
|
up to 3 months
|
birth till discharge from hospital (up to 3 months)
|
|
Head circumferences at discharge
Time Frame: up to 3 months
|
up to 3 months
|
|
|
Incidence of nosocomial infection
Time Frame: up to 3 months
|
up to 3 months
|
|
|
Incidence of retinopathy of prematurity
Time Frame: up to 3 months
|
up to 3 months
|
|
|
Incidence of intraventricular hemorrhage
Time Frame: 1 month
|
1 month
|
|
|
Incidence of bronchopulmonary dysplasia
Time Frame: at corrected gestational age of 36 weeks
|
at corrected gestational age of 36 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Wenhao Zhou, Dr., Key Laboratory of Neonatal Diseases, Ministry of Health
Publications and helpful links
General Publications
- Noise: a hazard for the fetus and newborn. American Academy of Pediatrics. Committee on Environmental Health. Pediatrics. 1997 Oct;100(4):724-7. No abstract available.
- Lasky RE, Williams AL. Noise and light exposures for extremely low birth weight newborns during their stay in the neonatal intensive care unit. Pediatrics. 2009 Feb;123(2):540-6. doi: 10.1542/peds.2007-3418.
- Laudert S, Liu WF, Blackington S, Perkins B, Martin S, Macmillan-York E, Graven S, Handyside J; NIC/Q 2005 Physical Environment Exploratory Group. Implementing potentially better practices to support the neurodevelopment of infants in the NICU. J Perinatol. 2007 Dec;27 Suppl 2:S75-93. doi: 10.1038/sj.jp.7211843.
- Morag I, Ohlsson A. Cycled light in the intensive care unit for preterm and low birth weight infants. Cochrane Database Syst Rev. 2013 Aug 3;(8):CD006982. doi: 10.1002/14651858.CD006982.pub3.
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CHFudanU_NNICU7
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.