Comparison of Femoral Tunnel and Clinical Outcome Using Two Anterior Cruciate Ligament Reconstruction Techniques

December 3, 2019 updated by: Samsung Medical Center

Comparison of Femoral Tunnel Placement, Geometry and Clinical Outcome Using Two Anterior Cruciate Ligament Reconstruction Technique; Transportal Technique and Outside in Technique With Remnant Preservation. Prospective Randomized Trial

  1. Purpose :To compare of femoral tunnel placement, tunnel geometry and clinical outcome using two anterior cruciate ligament reconstruction techniques ; transportal technique with flexible reamer and single bundle outside in technique with remnant preservation.
  2. Subjects: anterior cruciate ligament (ACL) injury 66 patients

    • Double bundle transportal technique with flexible reamer: 33
    • Single bundle outside in technique with remnant preservation: 33

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

Anterior cruciate ligament (ACL) injury patients : Total 66

  1. Double bundle transportal technique with flexible reamer: 33

    • Advantage: more normal ACL reconstruction than single bundle technique
    • Disadvantage: to make the two bone tunnel must remove all the residual tissue.
  2. Single bundle outside in technique with remnant preservation: 33

    • Advantage: good for being synovium and revascularization. Remained proprioception function helps to functional recovery.
    • Disadvantage: difficult to ensure of visibility and tunnel drilling in the correct position because of remnant tissue.

Study Type

Interventional

Enrollment (Actual)

67

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

20 years to 60 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Lachman test grade II,III and Pivot shift test grade II,III in physical examination
  2. ACL rupture in MRI
  3. Age 20~60
  4. within 6 months after trauma

Exclusion Criteria:

  1. osteoarthritis (OA) change in X-ray
  2. History of other ligament injury or ACL reconstruction in uninjured knee.
  3. operation history of either ipsilateral or contralateral knee(fracture, etc)

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Transportal
this is a type of anterior cruciate ligament reconstruction. this arm for patients who underwent operation with transportal technique
comparison of different types of anterior cruciate ligament reconstruction. transportal technique is double bundle graft using flexible reamer, outside-in technique is single bundle graft with remnant preservation
Experimental: Outside in
this is a type of anterior cruciate ligament reconstruction. this arm for patients who underwent operation with patients who underwent operation with outside in technique
comparison of different types of anterior cruciate ligament reconstruction. transportal technique is double bundle graft using flexible reamer, outside-in technique is single bundle graft with remnant preservation

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Vascularity of Graft Tendon
Time Frame: 1yr after surgery
For evaluation of graft vascularity, quantitative parameter of area under the curve (AUC) was measured from DCE-MRI by using an image-processing software (IntelliSpace Portal, version 5.0; Philips Healthcare). A musculoskeletal radiologist manually drew the ROIs for intra-articular portion of the ACL graft including synovial membrane at the proximal, middle and distal zones. The software automatically generated time to signal intensity curves and then calculated the quantitative parameter, area under the time to signal intensity curve values, which were acquired by integrating the area under the time to signal intensity curve. To normalize the AUC (nAUC), we divided the AUC of medial gastrocnemius muscle into that of the ACL graft.
1yr after surgery

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Arthroscopy Grading
Time Frame: 1yr after surgery

Graft continuity was graded as no tears, superficial tear (fibrillation or tear of superficial fibers), or substantial tear (rupture of 1 or more strands).

Graft tension was graded as taut, mild lax, and lax by probing at knee flexion and extension.

Synovial coverage of the grafts was graded as excellent (synovial coverage > 80% around graft), fair (coverage > 50%), or poor (coverage < 50%) On the second-look arthroscopic examination, graft continuity, graft tension, graft synovialization, and the presence of cyclops lesions were assessed by a senior surgeon.

1yr after surgery
Clinical Knee Scoring
Time Frame: 2 yr after surgery

Lysholm score (ragne 0-100), HSS (hospital for special surgery) score (0-100) , IKDC (international knee doucomentation commitee) subjective score (0-100), Tegner activity scale (0-10).

All of scores demonstrated that higher score means a better outcomes.

2 yr after surgery
Instability
Time Frame: 2 yr after surgery
The side-to-side difference was measured using a KT-200- arthrometer (MEDmetric) at 30 lb in 30° of knee flexion.
2 yr after surgery
Graft Maturity (SNQ)
Time Frame: 1 yr after surgery
1 yr after surgery

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Study Chair: Joon Ho Wang, MD, Ph D, Samsung Medical Center

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

May 1, 2014

Primary Completion (Actual)

May 1, 2014

Study Completion (Actual)

December 1, 2017

Study Registration Dates

First Submitted

February 22, 2015

First Submitted That Met QC Criteria

April 25, 2016

First Posted (Estimate)

April 28, 2016

Study Record Updates

Last Update Posted (Actual)

December 20, 2019

Last Update Submitted That Met QC Criteria

December 3, 2019

Last Verified

December 1, 2017

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • SMC2013-07-097-001

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

if yes, age, sex, physical examination, trauma date, MRI.

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.