Identification of Epidural Space Description of New Technique
Introduction Several attempts have been made to improve or facilitate epidural space detection beside conventional loss of resistant technique. Recently many sophisticated equipment's and techniques have been described which did not received widespread popularity.
Objectives The Investigator describes and assesses the validity of using Pressure Gauge Manometer to confirm correct detection of lumber epidural space, in an inexpensive way.
Methods Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments ( nearly 2cm mark on the needle).A3-way stopcock is connected to the hub of Tuohy needle with the in-line port of the stopcock attached to an air-filled 10 ml syringe. Using a 75 cm extension tube set and create a 30 mm Hg pressure gradient between manometer and the tip of epidural needle , the needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure suddenly dropped ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
• A total of 60 consecutive ASA class 1& II patients of ages between 28-68 years scheduled for elective surgery under lumber epidural anesthesia or under general anesthesia with planned post-operative epidural analgesia were enrolled in this study.
Patients with known coagulation disorder, allergy to local anesthetics, skin lesions at the puncture side, or neuromuscular disease were not included.
Patients are placed in sitting position and American society of anesthesiologists standard monitors attached. After skin preparation, draping, and local anesthetic infiltration, an epidural Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments ( nearly 2cm mark on the needle). Fig 1 A3-way stopcock is connected to the hub of Tuohy needle with the in-line port of the stopcock attached to an air-filled 10 ml syringe. Using a 75 cm extension tube set the side port is connected to the Pressure Gauge Manometer held by the assistant. The stopcock is turned so that the needle is in direct continuity with both syringe and pressure Gage manometer. The syringe is used to create a 30 mm Hg pressure reading on the manometer, the stopcock then is turned into "open" to manometer and Tuohy needle and "close" to syringe.
With this 30 mm Hg pressure gradient between manometer and the tip of epidural needle, the needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure changes ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
The 3-way is then removed and local anesthetic is injected for single shot epidural block or catheter is introduced in the conventional manner and secured by adhesive tap.
Procedure was performed by anesthetists of different levels of experience (consultant, specialist, resident).
Demographic data and type of surgery is recorded along with time of the technique, number of passes required to enter the epidural space, any false LOR, insertion difficulties, accidental dural puncture, or any other complication occurred.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Assiut, Egypt, 71515
- Assiut University ,Faculty Of Medicine ,Anesthesia Department, Egypt
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- ASA class 1& II patients of ages between 28-68 years scheduled for elective surgery under lumber epidural anesthesia or under general anesthesia with planned post-operative epidural analgesia were enrolled in this study.
Exclusion Criteria:
- Patients with known coagulation disorder, allergy to local anesthetics, skin lesions at the puncture side, or neuromuscular disease were not included
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Health Services Research
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Pressure Gauge Manometer
Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments .
The needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure suddenly dropped ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
|
Identification of epidural space
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Success of the technique.
Time Frame: 10 minutes after the technique.
|
For epidural catheter placement success of the technique is defined as the installation of sensory block after the end of surgery.
|
10 minutes after the technique.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
The physician satisfaction with the technique (Definitely not, Not completely, Yes)
Time Frame: 12hours after the end of the technique
|
12hours after the end of the technique
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Osama A Ibraheim, MD, Assiut University College of medicine
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 010007
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.